How we prove a lot is methylcobalamin
A methylcobalamin lot is the methyl form when four lines agree: the document names the form and CAS number, HPLC retention against a methylcobalamin standard and the UV-Vis spectrum match, the cobalamin profile shows no other form above its limit, and the assay and moisture close the mass balance. An assay expressed only as vitamin B12 cannot separate methylcobalamin from cyanocobalamin, because both are cobalamins with a similar response.
The methyl ligand is the identity: retention and the spectrum at about 267, 342 and 522 nm separate it from cyanocobalamin, and the cobalamin profile shows what else is in the peak.
The four identity layers
Paperwork can name methylcobalamin correctly while saying nothing about the solid in the drum. Each layer in the table asks a different question, and the answer to one does not cover the next. A supplier who stops at the first layer has described a label, not a lot.
| Layer | Question | Test | What it proves |
|---|---|---|---|
| Document | Is the form named? | Name, CAS number, formula | Paperwork only |
| Chromatography | Is the cobalamin methylcobalamin? | HPLC retention against a methyl standard plus UV-Vis spectrum | The ligand and the corrin ring |
| Profile | What else is in the peak? | HPLC for cyanocobalamin, hydroxocobalamin and other cobalamins | Purity of the form |
| Mass balance | Is it diluted? | Assay, loss on drying, impurities | Consistency of the numbers |
HPLC and UV-Vis: proving the methyl form
The method should name the column, the mobile phase, the wavelength, the solvent and the reference standard. Identity is retention time plus spectrum. A single peak at the right time can be another cobalamin or a degraded standard, so the spectrum is the second dimension rather than a decoration. Methylcobalamin in neutral solution shows maxima near 267, 342 and 522 nm; cyanocobalamin shows maxima near 361 and 550 nm. The gap between those sets is wide enough to read, provided the method uses the right standard and the right solvent.
Use a methylcobalamin reference standard for both identity and assay. Running a methyl sample against a cyanocobalamin standard with an assumed response factor produces a number that looks plausible and describes a different molecule. The standard should be traceable, within its expiry and stored as the certificate directs; a degraded standard changes the retention and the spectrum at the same time.
The ratios that carry the identity
Two ratios do the work. The first is the absorbance ratio at the three maxima. The method should state the ratios it expects, because the spectrum is pH-dependent: in dilute acid the maxima shift to about 264, 304 and 462 nm, so a spectrum measured in the wrong solvent will not match a neutral-solution reference. The second is the chromatographic ratio of the methylcobalamin peak area to the total cobalamin area. The specification should set a limit for each named cobalamin rather than one general purity figure, so that a cyanocobalamin impurity and a hydroxocobalamin impurity are both visible.
Cobalt is a supporting figure, not the deciding one. The methyl form is about 4.38% cobalt by mass and cyanocobalamin about 4.35%; the difference is too small to separate the two forms on a cobalt result. A cobalt figure near the theoretical value confirms that the material is a cobalamin and helps catch a dilution, but the ligand is proved by the chromatogram and the spectrum.
X-ray diffraction: the solid-state check
X-ray diffraction answers a different question: is the solid crystalline, and does its pattern match a reference? Methylcobalamin is supplied as a crystalline powder, so a pattern is meaningful; it can distinguish the crystal from an amorphous trituration or a lyophilised powder, and it can compare lots from two sources. On a diluted grade the carrier dominates the pattern, which is itself useful evidence of what was added.
XRD is not a purity assay and it does not identify the ligand. It is not a routine release test for this product, and a certificate that reports only “XRD conforms” without the pattern or the reference has added little. Ask for the reference pattern and the detection limit before reading a match statement. For a disputed lot, XRD plus HPLC/UV plus the cobalamin profile is stronger than any one of them.
What adulteration looks like
| Adulterant | What it does | Signal | Test |
|---|---|---|---|
| Cyanocobalamin | The other common B12 form; similar colour and assay response | Retention and spectrum differ; cyano peak present | HPLC/UV against a methyl standard |
| Hydroxocobalamin | Light-degradation product; red, so colour still passes | Extra peak; spectrum shift | HPLC profile, UV-Vis |
| Dilution on a carrier | Lowers the assay; adds a carrier | Assay low; loss on drying and ash move | Mass balance, carrier identification |
| Dye | Matches the dark red colour, not the spectrum | Colour without a UV match | UV-Vis, HPLC |
| Moisture | Raises loss on drying; lowers the as-is assay | LOD high; anhydrous assay normal | Loss on drying |
Colour is the weakest signal, because the molecule and its main degradation product are both red and a dye can reproduce the shade. The stronger signals are the retention time, the spectrum and the cobalamin ratio. A certificate that reports appearance and assay but not identity has left the most likely substitution untested.
How to write the identity into the specification
- “Methylcobalamin, CAS 13422-55-4, C63H91CoN13O14P.”
- “Assay 98.0–101.0% by HPLC against a methylcobalamin reference standard; state the basis.”
- “Identification by HPLC retention and UV-Vis spectrum; report the maxima and the absorbance ratios.”
- “Cobalamin profile: limits for cyanocobalamin and hydroxocobalamin, each reported separately.”
- “Loss on drying ≤10.0%; heavy metals and microbiology as listed.”
- “Particle size ≥95% through 80 mesh; pack in a light-resistant, moisture-barrier container.”
- “The destination market, the intended use and the form are agreed in writing before release.”
Questions to put to the supplier
- What is the form and CAS number printed on this lot's certificate?
- Can you provide the HPLC chromatogram and the full UV-Vis spectrum, not only the assay percentage?
- Which reference standard was used, and in which solvent was the spectrum measured?
- What are the cyanocobalamin and hydroxocobalamin results for this lot?
- If the lot is disputed, will you accept a joint re-test on the retained sample?
The five answers together make an identity file; any one alone leaves a gap. The product hub carries the catalog specification, the COA page shows where each result sits, the grades page compares the physical forms, the level-four comparison covers the label and stability consequences, the cyanocobalamin page covers the other form, the HPLC method note explains the separation, and the quality page describes release.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation