01 COA & batch testing

What the COA for D-chiro-inositol actually contains

Technical document 01 · Reviewed 2026-11-20 · D-Chiro Inositol

On this page
  1. Reading the certificate as evidence
  2. Assay basis, moisture and the isomer gap
  3. Gate and result are different columns
  4. Where one batch differs from the next
  5. When an outside laboratory earns its place
  6. Six things to line up between suppliers

Read a D-chiro-inositol certificate from the isomer outward. The document should name the cyclitol and its CAS number, show an assay that separates D-chiro from myo, and account for moisture, the metal panel, the microbial count and the sieve result. The figures in the table are the catalog gates; the lot's own numbers belong in a separate column, with the method that produced each one.

In one line

The isomer is the audit trail: a D-chiro figure counts only when the method separates it from myo, the basis is stated and the rest of the powder is accounted for.

Reading the certificate as evidence

Each line should survive three questions: what was tested, how, and against which gate. A row that says only “conforms” closes the question instead of answering it. The identity rows and the assay row are separate evidence, and in this product one does not imply the other.

Appearance is a release line — white to off-white, free-flowing powder — but a weak one, because the most likely substitute looks the same. The useful information sits in the isomer result and in the method behind it.

Release lines for a D-chiro-inositol lot
ParameterMethodRelease limit
IdentificationHPLC retention; infrared spectrumConforms to reference
Assay, D-chiroHPLC with refractive-index or light-scattering detection≥98.0%
Myo-inositolIsomer-resolving HPLCAgreed ceiling; reported per lot
Melting pointCapillary method225–230 °C
Loss on dryingGravimetric≤0.5%
Heavy metalsICP-MS, element by elementPb ≤3; As ≤2; Cd ≤1; Hg ≤0.1 mg/kg
Microbial countPlate countAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g
Absence testsEnrichment and isolationE. coli absent; Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

Assay basis, moisture and the isomer gap

The catalog asks for ≥98.0% and for loss on drying ≤0.5%, but it does not fix the assay basis in the parameter name. As-is and dried-basis figures are not interchangeable: 97.6% as received with 0.4% moisture becomes 98.0% on the dried basis, and a buyer comparing two certificates needs to know which convention each one uses. The basis belongs in the assay row, not in a footnote.

At 98.0%, two percent of the powder is something else. It could be myo-inositol, another cyclitol, water, a carrier from a dilution, or material carried over from a plant extraction. An assay that sums all inositols cannot say which. The lot needs a resolving method, a standard for each isomer and a stated ceiling for myo-inositol.

Inositol has no useful ultraviolet chromophore, which shapes the method. Most laboratories use refractive index, light scattering, or a derivatisation step ahead of ultraviolet or mass detection. Each has quirks: refractive index drifts with temperature, light scattering is not linear across a peak, and derivatisation adds recovery losses. The certificate should name the detector, column, mobile phase and standard, and the laboratory should show that the two isomers actually separate.

Melting point is the weakest identity line here. The catalog range of 225–230 °C sits on top of the myo range, so a pass says the solid is a crystalline inositol, not which one. It is a purity check that has been asked to do an isomer's job.

Gate and result are different columns

The gate is fixed by the specification; the result is what the lot produced. When the result column simply repeats the gate, the certificate has said nothing about the batch. Keep the two apart and put the method beside them.

What the result column should show
ParameterGateResult evidence
D-chiro assay≥98.0%Measured percentage, with the basis
Myo-inositolAgreed ceilingMeasured percentage from a resolving run
Loss on drying≤0.5%Measured percentage
Heavy metalsPer elementA figure for each element, not a total
MicrobiologyCounts and absenceThe lot's count and absence statement

“Passes specification” is a conclusion; the numbers should lead there without help. For the isomer that means a second value with its own ceiling, not a note that the main peak looked clean.

Where one batch differs from the next

Crystallisation changes habit and colour; drying changes moisture; milling changes the sieve result. A move from one mesh to another is a finishing change rather than a chemical one, yet the certificate still has to carry the new sieve figure and the specification has to name the mesh that was bought.

Source adds a second axis. An epimerised myo route and a plant extraction can both reach 98.0% while carrying different minor cyclitols and different residual sugars. Colour is a poor test but a useful hint: a batch that browns in storage points to sugar carry-over, not to an isomer failure.

Watch the direction of travel across several lots: an assay sliding toward the gate, moisture climbing, a myo peak growing. One result near an edge proves little; a sequence does. Tie each certificate to the pack and the retained sample by lot code, and count a missing lot code as a documentation defect.

When an outside laboratory earns its place

Independent testing makes sense at four moments: a new source, a first entry into a regulated market, a label that declares D-chiro while the certificate reports only total inositol, and a disagreement about a specific lot. The panel should not be a photocopy of the certificate. Ask for a resolving assay with a myo standard and a spiked sample, optical rotation, moisture, ICP-MS and a plate count.

Add nuclear magnetic resonance if an unidentified cyclitol appears, and ask for the detection limit behind every “not detected” statement. Without that limit the line describes the method's sensitivity, not the sample.

Keep the chain intact. The sample that was tested should be the sample that was retained, and the report should carry the lot code. A referee needs the specification, the retained sample and a method capable of separating the isomers; a repeat of the same sum assay will not settle an isomer dispute.

Six things to line up between suppliers

Compare the isomer and CAS number; the assay and its basis; the myo figure and the method behind it; moisture; the metal and microbial results; and the pack with its lot code. Agreement on the assay alone can conceal a different isomer or a different basis.

Start with the specification on the D-chiro-inositol product page, then read the isomer evidence on the identity page. The supply forms are set out on the grades page; the detection choices are described in the methods section; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation