What the COA for adenosylcobalamin actually contains
The number that matters on an adenosylcobalamin certificate is the assay, but the number cannot stand alone. The certificate has to name the standard the HPLC ran against, state whether the percentage is as-is or dried, and show the moisture figure that connects the two. Without those three items the percentage is a result without a subject.
The assay is a figure about the adenosyl form: it needs the HPLC standard named, the basis stated beside the loss on drying, and a spectrum that shows the adenosyl ligand rather than another cobalamin.
The certificate as a test report
Read the identity rows before the assay row. Adenosylcobalamin is defined by the 5'-deoxyadenosyl group on the cobalt, and a retention time without a spectrum can belong to methylcobalamin or cyanocobalamin. The certificate should report the retention, the UV-Vis maxima and the reference standard, so the reader can see which molecule was measured.
An assay row that says “≥95.0%” and nothing else hides its basis. Loss on drying is the other half of the statement, because the same powder reads differently as-is and on the dried basis.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Red-orange to dark red, crystalline powder |
| Identification | HPLC retention and UV-Vis spectrum | Conforms to the adenosylcobalamin reference |
| Assay | HPLC with UV detection | ≥95.0% |
| Loss on drying | Gravimetric | ≤10.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
Assay basis, water and the identity standard
The catalog gate is ≥95.0% by HPLC, and the specification does not fix a basis. That is workable only if the certificate states one. Take a powder at 90.5% as-is with 5.0% water: the dried-basis calculation is 95.3%, so the same data pass or fail depending on the column heading. Buyer and supplier should agree the basis in writing before the first lot.
A 1,000 µg serving weighs about a milligram, which makes the as-is figure the one that sizes the fill; the dried figure is a release convention. Both are useful, and neither replaces the moisture result.
The identity standard has to be adenosylcobalamin, not a generic B12 standard. In neutral solution the spectrum shows bands near 260, 375 and 522 nm, and the 375 nm band separates this form from methylcobalamin (342 nm) and cyanocobalamin (361 nm).
Release limit versus batch result
A specification limit and a measured result are two different statements. The limit is the boundary the lot had to meet; the result is what the laboratory found. A certificate that prints the limit in the result column has reported the gate, not the sample.
| Parameter | Release limit | Result column |
|---|---|---|
| Assay | ≥95.0%, basis stated | A measured percentage with the basis and the standard named |
| Loss on drying | ≤10.0% | A measured percentage |
| Identification | Conforms to the reference | Retention time, spectrum and the ratios used |
| Heavy metals | Per element | A measured figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
| Particle size | ≥95% through 80 mesh | The measured percentage through the sieve |
The result column should let a reader rebuild the pass decision: a number and unit for each metal, a colony count plus an absence statement for the micro tests, and an assay figure with its basis. A single “passes specification” line is a conclusion without the route to it.
What moves between batches
Between lots, the final step and crystallisation move colour and assay, drying moves moisture, and the mill moves the 80 mesh fraction. None of these changes is automatically a defect; the trend across lots is what deserves attention.
Light is the variable specific to this molecule. The adenosyl group can be lost at the powder surface during sampling, so a certificate from a lot sampled under bright light may show a lower assay than the drum would have given. Ask how the sample was handled, and keep the retained portion in the dark.
A colour shift from red-orange toward dark red is weak evidence, because the photoproduct is red too. An extra peak in the cobalamin profile or a falling assay across consecutive lots is stronger. Trace the lot code from certificate to pouch, drum and retain sample.
When an outside test is worth ordering
Order an outside panel when the source is new, the destination is regulated, the form is disputed or the lot has a light-exposure history. The panel should include HPLC with an adenosyl standard and a UV-Vis spectrum, the cobalamin profile, loss on drying, ICP-MS metals and microbiology.
Cobalt by ICP-OES sits near 3.7% for this molecule, lower than methylcobalamin at about 4.4%, so a result near 3.7% supports the identity and catches dilution. It does not replace the chromatogram: the ligand is what the method has to show.
Ask for the detection limit behind every “not detected” and keep the tested portion as the retained sample. A report without a lot code and a detection limit is difficult to defend later.
What to compare between suppliers
Compare six fields: CAS number, assay and basis, identity standard and spectrum, loss on drying, cobalamin profile, and pack plus lot code. A quotation that leaves out the standard or the basis cannot be compared with one that states them.
Look at traceability next: the manufacturer, the process and drying steps, and the light barrier on the pack. The catalog specification sits on the adenosylcobalamin product page; the form tests are on the identity page; the market questions are on the compliance page; the HPLC method is in the methods library; the release workflow is on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation