05 Compliance

The regulatory file for adenosylcobalamin

Technical document 05 · Reviewed 2026-11-20 · Adenosylcobalamin

On this page
  1. What the file contains
  2. European Union
  3. United States
  4. Contaminants and limits
  5. Claims and the label
  6. Documents for the adenosylcobalamin file
  7. Checklist before the first order

A compliance file for a B12 ingredient answers three practical questions: is the form permitted in the destination market, does this lot meet the specification that was filed, and does the label describe the ingredient without drifting into a claim? The brand placing the product on the market owns those answers. This page sets out the records and the boundaries, and it makes no disease-related claim.

In one line

A B12 file stands on three legs: the named form, lot data against the limits, and a label that declares the nutrient without inventing a claim.

What the file contains

The file begins with the ingredient name. “Vitamin B12” is a nutrient family; adenosylcobalamin is one member with its own CAS number, specification and label entry. Every document that describes the material should use the member name, and the file should quote the exact legal entry or marketing basis relied on.

Four records sit behind that name: the current specification, the lot certificate, the label and claim review, and the change history for source, process and pack. The technical data sheet and safety data sheet support the review but do not replace the destination text. The COA is the lot record, not the legal route.

European Union

Directive 2002/46/EC, Annex II, is the first place to look: it lists 5'-deoxyadenosylcobalamin as one of the vitamin B12 forms permitted in food supplements. The reference is form-specific and should be quoted that way, as of this review.

Regulation (EU) No 1169/2011 sets the label: vitamin B12 in µg per portion and per 100 g, a percentage of the 2.5 µg reference value, and the form in the ingredient list. Contaminants are covered by Commission Regulation (EU) 2023/915. Read the consolidated text and the member-state practice, and record the version checked in the file.

United States

A US supplement carries adenosylcobalamin as a dietary ingredient and is made under 21 CFR 111. The Supplement Facts panel gives vitamin B12 in µg and as a percentage of the 2.4 µg Daily Value. The ingredient list supplies the form.

The marketing basis for the ingredient — pre-1994 use or a notification — is a supplier statement, and the buyer confirms that it extends to the finished product. Federal law sets no general heavy-metal limit for supplements; the specification, state law and the finished-product risk assessment set the working limits. Structure/function claims need the DSHEA disclaimer and substantiation, and no disease claim is made here.

Contaminants and limits

The numbers apply to the food as eaten, not to the drum. A microgram dose makes the raw material a tiny share of the capsule, so a lot at the limit can still fit — or fail once the rest of the formula is counted. Convert the lot result to the serving and keep the calculation in the file.

Heavy metals to confirm for the finished product
ParameterEU supplement ceilingCatalog specificationWhat the file should show
Lead (Pb)3.0 mg/kg≤3 mg/kgLot result, method and the finished-product calculation
Cadmium (Cd)1.0 mg/kg≤1 mg/kgLot result and any category exception that applies
Mercury (Hg)0.1 mg/kg≤0.1 mg/kgLot result and method
Arsenic (As)No general EU ceiling≤2 mg/kgThe agreed limit and the method, stated on the certificate

Claims and the label

EU and UK health claims are restricted to the authorised list, with the authorised wording and conditions. They attach to vitamin B12, not to the adenosyl ligand, so the form neither creates a claim nor removes the need for authorisation. A US structure/function claim needs the disclaimer and substantiation.

The label facts belong in the file separately: nutrient name and amount, ingredient name, and carrier where a dilution is used. A claim review is its own document with its own reviewer. A certificate supports the material, not the wording, and a change of claim does not reopen the specification.

Documents for the adenosylcobalamin file

Documents that travel with an adenosylcobalamin lot
DocumentWhat it showsWhen it is needed
Batch COAResults against the specification, with methods and basisEvery shipment
Technical data sheetCatalog specification, pack and storageFirst order and technical review
Safety data sheetHandling, dust and disposal informationEvery shipment and for EHS
Agreed specificationCustomer limits, identity standard and basisBefore the first order
Allergen and non-GMO statementsCarrier and processing positionLabel review and customer request
Origin and change-control recordManufacturer, site, process and pack changesQualification and audit
Stability and retest dataPack, conditions and the supported periodQuality agreement

Each document should carry the same lot code, and the specification version on the certificate should match the quotation. The analytical method behind the certificate is described in the methods library.

Checklist before the first order

  • The specification, CAS number and adenosyl form are all named.
  • Each destination has its permitted-form route and label rules on file, with the version date.
  • The document set is complete: COA, TDS, SDS, allergen, non-GMO, origin and change control.
  • Contaminant results are calculated at the finished-product dose.
  • The ingredient list names adenosylcobalamin; the nutrient line gives vitamin B12; any carrier is declared.
  • Any claim is authorised and substantiated; no disease claim is made.
  • Quotation, specification and certificate carry the same version.

The product hub carries the catalog specification; the identity page covers the analytical evidence; the methylcobalamin product page describes the adjacent form; the quality page describes the release file.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation