01 COA & batch testing

What the COA for ubiquinol actually contains

Technical document 01 · Reviewed 2026-11-20 · Ubiquinol

On this page
  1. What each row should carry
  2. The assay basis and the water beside it
  3. The gate and the measured result
  4. What shifts from lot to lot
  5. When an outside laboratory is warranted
  6. Six lines for a supplier comparison

A ubiquinol certificate normally carries appearance, HPLC/UV identification, two assay lines for ubiquinol and ubiquinone, loss on drying, heavy metals, microbiology and the particle-size result. The two assay lines belong together: ubiquinol is the reduced form and ubiquinone is what it becomes when it oxidises. A certificate that reports only a “CoQ10” total has not said which form the lot contains.

In one line

The ubiquinol figure is only half the certificate: the ubiquinone result beside it, the assay basis and a method that sees both forms decide what the lot actually is.

What each row should carry

A row earns its place on the page when it says what was measured, how, and against which gate. The measured value belongs in a column of its own; a bare “conforms” states an outcome and leaves the reader unable to check it.

The identification row separates ubiquinol from ubiquinone. The two assay rows carry the quantities.

Ubiquinol release tests: method and limit
ParameterMethodRelease limit
AppearanceVisualWhite to pale yellow powder or oil
IdentificationHPLC retention and UV spectrumConforms to the reference
Assay, ubiquinolHPLC with UV detection≥95.0%
UbiquinoneHPLC with UV detection≤2.0%
Loss on dryingGravimetric≤5.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

The assay basis and the water beside it

The assay needs a basis. The catalog sets ≥95.0%, but the catalog line does not state whether that figure is as-is or on the anhydrous basis. The basis belongs in the assay row itself, not in a note at the bottom.

Moisture is what separates the two bases. Take a powder that measures 95.0% as-is and carries 3.0% loss on drying: the anhydrous figure is 97.9%. Express the same 95.0% on the anhydrous basis and the as-is figure falls to 92.2%. The label on both could read “95% ubiquinol”; the powders behind the two numbers are not the same.

The USP monograph for ubiquinol sets 96.0–102.0% on the anhydrous basis. A result of 95.5% on that basis is above the catalog's 95.0% number but below the monograph's 96.0% floor. Decide which gate the destination needs before the certificate is written, and put the loss on drying beside the assay as a measured figure rather than a limit.

The gate and the measured result

One column is the gate the lot had to pass; the other is the number the laboratory obtained. They should not contain the same figures.

Release gates and measured results · ubiquinol
ParameterRelease limitResult column
Ubiquinol≥95.0%A measured percentage, with the basis and the wavelength
Ubiquinone≤2.0%A measured percentage, separate from the ubiquinol figure
Loss on drying≤5.0%A measured percentage
Heavy metalsPer elementA measured figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot

Do not replace the two assay lines with a single “total CoQ10” figure. If a total is reported, the ubiquinol and ubiquinone results should still appear, because the split is the oxidation state. The sum of ubiquinol, ubiquinone, moisture and impurities is the mass balance; the two assay limits are independent gates, not a recipe that adds to 100%.

What shifts from lot to lot

Ubiquinol is not a passive powder. It oxidises to ubiquinone on exposure to air, light and heat, so the ubiquinone line moves with the age of the lot, the sampling technique and the time between opening the pack and preparing the sample. The same drum can read differently in two laboratories when the sample handling and the delay before injection differ.

The certificate should say how the sample was handled: amber glass, a nitrogen or inert headspace, and analysis without a long hold. A method that reads only the ubiquinone wavelength can under-report the reduced form, so the wavelength and the standard belong on the page.

Colour is the weakest quantitative evidence. White to pale yellow is the reduced form; a shift towards orange suggests oxidation, but a batch can darken for other reasons. Use colour as a prompt to check the ubiquinone figure, not as a release test.

When an outside laboratory is warranted

An outside laboratory earns its place for a new source, a first shipment, a disputed oxidation figure, or a certificate that gives only a total CoQ10 result. The useful panel is HPLC with dual-wavelength UV detection or electrochemical detection, ubiquinol and ubiquinone reported separately, loss on drying, ICP-MS for the heavy metals, microbiology, and a check of the sample handling.

Require the method's detection limit and a short description of how the sample was protected before injection. “Ubiquinone not detected” means little unless the report states the limit it was tested against. If an unknown peak appears, high-resolution mass spectrometry or NMR can identify it; a second HPLC run at the same wavelength cannot.

Chain of custody matters. The referee should test the retained sample, and the report should carry the lot code. A re-test is only useful when both sides agree on the sample, the method and the basis.

Six lines for a supplier comparison

Compare six lines: form and CAS number; ubiquinol result and basis; ubiquinone result; the HPLC wavelength or detector; loss on drying; and the pack with its lot code. Two quotations that agree on “CoQ10 98%” can still describe different redox forms and different analytical methods.

The second layer is traceability: who manufactured the lot, which process and carrier were used, and how the pack was sealed. Catalog data for this material is on the ubiquinol product page. Analytical separation is explained under methods; the identity page covers the form tests; the compliance page covers the market file; quality covers release.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.