Ubiquinol grades: powder, oil and the oxidation limit
Ubiquinol is offered as a powder or an oil; a carrier-based grade is a separate purchase. The catalog form is a powder at ≥95.0% ubiquinol with ubiquinone ≤2.0% and ≥95% through 80 mesh, and the oil is quoted on request. The grade decision is about the dosage form, the oxidation headroom and the label, not about a higher number on a certificate.
The grade is the presentation and the oxidation headroom: a powder, an oil or a diluted form each carries its own ubiquinone limit and handling rule.
Why ubiquinol needs more than one grade
Ubiquinol is a low-melting, fat-soluble solid that oxidises to ubiquinone. A powder is easy to weigh into a capsule or a tablet; an oil is easy to fill into a softgel or to blend into an oil-based formula. The same active at the same assay behaves differently in those two presentations, because the surface exposed to air and the carrier around it are different.
The grade also fixes the specification. A powder at 80 mesh has a particle-size line; an oil has no mesh line but has a carrier and a peroxide value. A carrier-based dilution has a different assay per gram and a label that must declare the carrier. None of those is a packing choice.
The grades side by side
| Grade | Form | Catalog position | Fits | What changes |
|---|---|---|---|---|
| Powder, 80 mesh | White to pale yellow powder | Catalog | Capsules, tablets, dry blends | Particle size, dust, loss on drying |
| Oil | Oil solution or suspension | On request | Softgels, oil blends | Carrier, fill weight, peroxide value |
| Tighter specification | Powder or oil | Agreed in the specification | Long shelf life or a sensitive label | Assay and ubiquinone limits, method |
| Carrier-based powder | Active on a carrier | Not a catalog form | Low-dose units, dispersible systems | Assay per gram, carrier declaration, label |
The first two rows are the catalog. The third is a tighter version of the same material, not a different substance. The fourth is a different purchase: if a formula needs a carrier-based grade, it has to be specified and quoted separately, because the assay per gram and the label both change.
Powder, oil and the handling difference
The powder is white to pale yellow and is specified at ≥95% through 80 mesh. It is insoluble in water and belongs in an oil phase, an emulsion or a dry blend. The oil is a solution or suspension in a carrier; its ubiquinol content is expressed per gram, and its oxidation state depends on the carrier, the headspace and the fill temperature.
Both forms are oxygen-sensitive. The powder has a larger surface area per gram and picks up oxygen at the surface; the oil dissolves oxygen, and a warm hold speeds the reaction. Light accelerates both. A clear bottle, a warm bench and an open drum are the three common exposures.
Melting behaviour matters in processing. Ubiquinol melts at about 49 °C, so a hot fill or a heated blend can melt the powder and change its solid state. If the process relies on the crystalline powder, check the solid state after cooling; a melted and re-solidified lot can retain the assay while its bulk density and flow change.
The dosage form decides the grade
A two-piece capsule or a tablet takes the powder; a softgel takes an oil suspension or a powder dispersed in oil; an oil blend takes the oil. A tablet also adds compression heat and pressure, which the powder sees and the oil does not.
Dose is a label decision, not a grade decision. The label should name ubiquinol and declare the amount per serving in the form the market requires. The certificate's assay is not the label dose: a 100 mg fill of a 95.0% powder carries 95 mg of ubiquinol before any overage or loss. That is arithmetic, not a recommended intake.
If the formula needs a lower active weight per unit, a carrier-based grade is the usual route, but it is a separate specification with its own assay per gram and its own label declaration. Do not regard a dilution as the same grade at a lower number.
The lines that belong in the specification
- “Ubiquinol, CAS 992-78-9, C59H92O4, powder or oil as stated.”
- “Assay ≥95.0% by HPLC; state the basis; ubiquinone ≤2.0% by HPLC.”
- “Identification by HPLC retention and UV spectrum; name the wavelength or detector.”
- “Loss on drying ≤5.0%; heavy metals and microbiology as listed.”
- “Powder: ≥95% through 80 mesh. Oil: carrier, fill weight and peroxide value stated.”
- “Pack, storage condition and retest period stated; oxidation-sensitive handling noted.”
A specification that names only “ubiquinol powder” has left the grade, the mesh and the oxidation limit to the supplier. Name the presentation, the assay basis and the ubiquinone ceiling before the quotation.
When another grade is the wrong choice
Ubiquinol is the wrong choice when the label names ubiquinone, when the process cannot exclude oxygen, or when the market file covers only the oxidised form. It is also the wrong choice when the formula is aqueous and has no oil phase: the material is fat-soluble, and a suspension in water is not the same as a solution.
If the buyer needs the more oxidation-stable form, ubiquinone is the starting point; the comparison is on the level-four page. The catalog specification is on the product page; the release tests are on the COA page; the pack and lead time are on the MOQ page; the storage rules are on the stability page.
In this document
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation