02 Grades & formats

Ubiquinol grades: powder, oil and the oxidation limit

Technical document 02 · Reviewed 2026-11-20 · Ubiquinol

On this page
  1. Why ubiquinol needs more than one grade
  2. The grades side by side
  3. Powder, oil and the handling difference
  4. The dosage form decides the grade
  5. The lines that belong in the specification
  6. When another grade is the wrong choice

Ubiquinol is offered as a powder or an oil; a carrier-based grade is a separate purchase. The catalog form is a powder at ≥95.0% ubiquinol with ubiquinone ≤2.0% and ≥95% through 80 mesh, and the oil is quoted on request. The grade decision is about the dosage form, the oxidation headroom and the label, not about a higher number on a certificate.

In one line

The grade is the presentation and the oxidation headroom: a powder, an oil or a diluted form each carries its own ubiquinone limit and handling rule.

Why ubiquinol needs more than one grade

Ubiquinol is a low-melting, fat-soluble solid that oxidises to ubiquinone. A powder is easy to weigh into a capsule or a tablet; an oil is easy to fill into a softgel or to blend into an oil-based formula. The same active at the same assay behaves differently in those two presentations, because the surface exposed to air and the carrier around it are different.

The grade also fixes the specification. A powder at 80 mesh has a particle-size line; an oil has no mesh line but has a carrier and a peroxide value. A carrier-based dilution has a different assay per gram and a label that must declare the carrier. None of those is a packing choice.

The grades side by side

Ubiquinol presentations and what changes with each
GradeFormCatalog positionFitsWhat changes
Powder, 80 meshWhite to pale yellow powderCatalogCapsules, tablets, dry blendsParticle size, dust, loss on drying
OilOil solution or suspensionOn requestSoftgels, oil blendsCarrier, fill weight, peroxide value
Tighter specificationPowder or oilAgreed in the specificationLong shelf life or a sensitive labelAssay and ubiquinone limits, method
Carrier-based powderActive on a carrierNot a catalog formLow-dose units, dispersible systemsAssay per gram, carrier declaration, label

The first two rows are the catalog. The third is a tighter version of the same material, not a different substance. The fourth is a different purchase: if a formula needs a carrier-based grade, it has to be specified and quoted separately, because the assay per gram and the label both change.

Powder, oil and the handling difference

The powder is white to pale yellow and is specified at ≥95% through 80 mesh. It is insoluble in water and belongs in an oil phase, an emulsion or a dry blend. The oil is a solution or suspension in a carrier; its ubiquinol content is expressed per gram, and its oxidation state depends on the carrier, the headspace and the fill temperature.

Both forms are oxygen-sensitive. The powder has a larger surface area per gram and picks up oxygen at the surface; the oil dissolves oxygen, and a warm hold speeds the reaction. Light accelerates both. A clear bottle, a warm bench and an open drum are the three common exposures.

Melting behaviour matters in processing. Ubiquinol melts at about 49 °C, so a hot fill or a heated blend can melt the powder and change its solid state. If the process relies on the crystalline powder, check the solid state after cooling; a melted and re-solidified lot can retain the assay while its bulk density and flow change.

The dosage form decides the grade

A two-piece capsule or a tablet takes the powder; a softgel takes an oil suspension or a powder dispersed in oil; an oil blend takes the oil. A tablet also adds compression heat and pressure, which the powder sees and the oil does not.

Dose is a label decision, not a grade decision. The label should name ubiquinol and declare the amount per serving in the form the market requires. The certificate's assay is not the label dose: a 100 mg fill of a 95.0% powder carries 95 mg of ubiquinol before any overage or loss. That is arithmetic, not a recommended intake.

If the formula needs a lower active weight per unit, a carrier-based grade is the usual route, but it is a separate specification with its own assay per gram and its own label declaration. Do not regard a dilution as the same grade at a lower number.

The lines that belong in the specification

  • “Ubiquinol, CAS 992-78-9, C59H92O4, powder or oil as stated.”
  • “Assay ≥95.0% by HPLC; state the basis; ubiquinone ≤2.0% by HPLC.”
  • “Identification by HPLC retention and UV spectrum; name the wavelength or detector.”
  • “Loss on drying ≤5.0%; heavy metals and microbiology as listed.”
  • “Powder: ≥95% through 80 mesh. Oil: carrier, fill weight and peroxide value stated.”
  • “Pack, storage condition and retest period stated; oxidation-sensitive handling noted.”

A specification that names only “ubiquinol powder” has left the grade, the mesh and the oxidation limit to the supplier. Name the presentation, the assay basis and the ubiquinone ceiling before the quotation.

When another grade is the wrong choice

Ubiquinol is the wrong choice when the label names ubiquinone, when the process cannot exclude oxygen, or when the market file covers only the oxidised form. It is also the wrong choice when the formula is aqueous and has no oil phase: the material is fat-soluble, and a suspension in water is not the same as a solution.

If the buyer needs the more oxidation-stable form, ubiquinone is the starting point; the comparison is on the level-four page. The catalog specification is on the product page; the release tests are on the COA page; the pack and lead time are on the MOQ page; the storage rules are on the stability page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation