What the COA for NMN actually contains
The NMN certificate starts with the material itself: appearance, CAS and formula, identification by HPLC and 1H NMR, then purity by HPLC, pH of a 5% solution, Karl Fischer water, particle size, the heavy-metal panel and microbiology; a β-NMN claim also needs the α/β ratio from the NMR. Every line needs a method and a release limit. The limits on this page describe the catalog grade; the lot-specific figures belong on the batch COA. A 98.0% purity figure on its own does not say which anomer or which solid form was tested.
A purity peak is not a specification: the certificate has to show the method, the anomer ratio, the water and the pH that belong to the lot.
Reading the certificate line by line
Every certificate line should stand on its own: what was measured, how, and against which limit. HPLC shows that the main peak matches a reference standard, and 1H NMR shows the structure and the anomer. The two are not interchangeable.
| Parameter | Method | Catalog limit |
|---|---|---|
| Appearance | Visual | White to off-white powder |
| CAS | Registry number | 1094-61-7 |
| Formula | Molecular formula | C11H15N2O8P |
| Identification | HPLC retention and UV spectrum | Conforms to the reference standard |
| Identification | 1H NMR | Conforms to the β-NMN structure |
| Purity (β-NMN) | HPLC, UV detection | ≥98.0% |
| pH (5% solution) | Potentiometry | 2.0–4.0 |
| Water | Karl Fischer | ≤5.0% |
| Parameter | Method | Catalog limit |
|---|---|---|
| Particle size | Sieve analysis | ≥95% through 40 mesh |
| Heavy metals | ICP-MS | Lead ≤3 · arsenic ≤2 · cadmium ≤1 · mercury ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
What the HPLC and NMR results measure
The HPLC figure is an area percentage, not a mass balance. The certificate should name the column, the mobile phase, the detection wavelength, whether the method resolves the α and β anomers, and whether the result is by area normalisation or against an external standard. Area normalisation assumes every component has a similar response; water, phosphate salts and residual solvent do not appear, so a 98.0% area result can sit beside 5.0% water.
The NMR line is an identity test. A one-dimensional 1H spectrum shows the nicotinamide ring and the ribose anomeric proton; a 31P experiment, where available, shows the phosphate. Neither is a purity assay unless the laboratory runs quantitative NMR. The anomer ratio is read from the anomeric signals. The spectrum should be attached to the certificate, not reduced to the word “conforms”.
pH and water are release tests because they describe the solid the customer receives. pH is measured on a 5% solution, so the concentration belongs in the method; a result without it cannot be compared with another laboratory. Karl Fischer is the practical check on drying and pickup during packing. NMN is hygroscopic, so exposure before the test is part of the result.
Where the limit ends and the result begins
One number is the acceptance boundary; the other is what the laboratory found. A certificate should keep them apart and print the method beside each. If the result column merely repeats the specification range, the document has restated the gate rather than reported a lot.
| Line | Catalog limit | What the batch COA must show |
|---|---|---|
| Purity | ≥98.0% by HPLC | Lot-specific area %, chromatogram and method |
| Anomer ratio | Reported; limit agreed in writing | β/α ratio from the NMR spectrum |
| pH | 2.0–4.0 at 5% | Lot-specific pH at the stated concentration |
| Water | ≤5.0% by Karl Fischer | Lot-specific water result |
| Particle size | ≥95% through 40 mesh | Sieve result and mesh used |
| Heavy metals | Lead ≤3 · arsenic ≤2 · cadmium ≤1 · mercury ≤0.1 mg/kg | Each element, method and quantification limit |
| Microbiology | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent | Plate counts and absence results |
The anomer line is the one most easily left off. If the certificate says “NMR conforms” and nothing else, the buyer cannot tell whether the lot is almost entirely β or a mixture. Ask for the ratio and the spectrum. Water moves the same way: two lots can both pass ≤5.0% and still behave differently in a capsule.
What moves between NMN lots
The anomer ratio is set by the coupling and the crystallisation. Water is set by the drying step and the pack. pH follows the isolation and any residual acid, and particle size follows milling and sieving. Colour can move with drying temperature or a trace metal while HPLC stays inside the limit.
Related substances are the other variable. The certificate should report the main related peaks, not only the parent. A method that integrates only the NMN peak can hide a growing nicotinamide riboside or nicotinamide peak. Read three or four consecutive lots, not one: water rising across deliveries or a widening anomer ratio is more useful than a single value near a limit.
When an outside laboratory earns its place
An outside laboratory is worth commissioning when the source is new, the market is regulated, the anomer result is contested, or the certificate does not support the form being sold. The useful panel is not a repeat: HPLC with a photodiode array for peak purity, 1H and 31P NMR for identity and anomer ratio, Karl Fischer for water, a residual solvent screen, ICP-MS for the metal panel, and a plate count for microbiology, on one sample.
Ask the laboratory to report its limit of detection and limit of quantification for each method. “Not detected” without a limit is a statement about the method, not about the sample. Ask whether the laboratory is accredited to ISO/IEC 17025 for the specific test.
Six lines for a supplier comparison
| Line | What to compare | Why it changes the answer |
|---|---|---|
| Form | Free acid or salt; anhydrous or hydrate | Changes the mass basis and the label |
| Anomer | β/α ratio by NMR, with the spectrum | HPLC purity can hide the α form |
| HPLC method | Column, wavelength, standard, integration | Area % is method-dependent |
| Water and pH | Karl Fischer result; pH at 5% | Both are release tests, not footnotes |
| Related substances | Nicotinamide riboside, nicotinamide, unspecified peaks, residual solvents | A single peak is not a purity profile |
| Regulatory statement | Market and use named, dated | A COA is not an authorisation |
The catalog specification is on the NMN product page. The tests that separate β-NMN from its analogs are on the identity page; presentation choices are on the grade page; the comparison with nicotinamide riboside is on the NMN versus NR page. The lot-release process is set out on the quality page, and the published specifications sit in the specification index.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation