06 Identity & adulteration

How we prove a nicotinamide riboside lot is the chloride salt

Technical document 06 · Reviewed 2026-11-19 · Nicotinamide Riboside

On this page
  1. Five layers of evidence
  2. The chloride ratio: proving the salt
  3. X-ray diffraction: solid form
  4. Substitutions and their signals
  5. Identity clauses for the specification
  6. Questions to put to the supplier

A nicotinamide riboside chloride lot is confirmed when five measurements agree: the document names the salt and CAS 23111-00-4; HPLC retention and UV match the reference; 1H NMR shows the nicotinamide ring and the ribose; chloride falls between 12.0% and 13.0%; and assay, water and chloride reconcile. A percentage cannot distinguish the salt from the free base or a diluted powder. Chloride is the counter-ion check.

In one line

Identity is a set of agreeing measurements: HPLC and NMR say the nucleoside, chloride says the salt, and water closes the balance.

Five layers of evidence

Identity is not one test. It is a chain of answers, and each link can fail while the others hold. The layers below ask different questions and call for different evidence. A reply that covers only the first link describes the paperwork, not the material.

Layers of nicotinamide riboside chloride identity
LayerQuestionTestWhat it proves
DocumentIs the form on paper?Name, CAS number, formulaOnly the paperwork
ChromatographyIs the nucleoside peak there?HPLC retention and UV spectrumThe molecule, not the anion
StructureIs the structure right?1H NMRThe ring and the ribose
Counter-ionIs chloride the counter-ion?Ion chromatography or titrationThe salt form
Mass balanceDoes the mass add up?Assay, water, chlorideDilution or moisture

NMR tells this nucleoside from a related nicotinamide; chloride tells the salt from the free base. Neither is a purity assay, and one does not substitute for the other.

The chloride ratio: proving the salt

There is one chloride per molecule. The theoretical content is 35.45 ÷ 290.70 = 12.19% by mass, so the catalog window of 12.0–13.0% can be predicted from the formula. Inside that window, with a 98.0–102.0% assay, the result is consistent with the chloride salt. Below it, consider free base, a carrier or another anion; above it, residual chloride or a different salt.

The same arithmetic gives the nucleoside share: 254.24 ÷ 290.70 = 87.5% of the salt's mass. A 98% assay on the salt is therefore not 98% of the nucleoside. The label, the dose and the COA should agree on which figure they are quoting.

The ratio also exposes a blend. Salt plus free base can be adjusted to sit inside the assay window, but the chloride result drops below 12.0% in proportion to the free-base fraction. HPLC sees the nucleoside; chloride sees the counter-ion. That is the strongest reason to keep chloride on the COA.

Ion chromatography and titration are not equally selective, so ask which technique produced the figure and read it beside water, both calculated on the powder as received.

X-ray diffraction: solid form

X-ray diffraction asks whether the solid has a crystal lattice that matches a reference. It can tell a crystalline solid from an amorphous dilution and compare lots from two suppliers. It cannot measure purity or the counter-ion. Request the reference pattern and the detection limit before a match is accepted.

Diffraction, chloride, HPLC and NMR together are stronger than any one of them. It is not a routine release test here, and a certificate that says only “XRD conforms” without the pattern adds little. It is most useful when the question is solid form.

Substitutions and their signals

Common nicotinamide riboside chloride substitutions and the signals
AdulterantWhat it doesSignalTest
Free baseNo chloride; MW 254.24Chloride under 12.0%; assay mismatchChloride, 1H NMR, mass balance
NMNCarries a 5'-phosphate (MW 334.22)Phosphate present; different retentionHPLC resolution, 31P NMR
NicotinamideHydrolysis fragment; small moleculeEarly peak; low molecular weightHPLC related substances, NMR
DilutionAssay and chloride fall togetherBoth below rangeMass balance, chloride
MoistureWater up; as-is assay downWater above 2.0%; dried basis normalKarl Fischer, assay basis

Colour proves little. White to off-white covers a wide range, and a yellow tint can follow heat or a trace metal while the assay passes. The useful signals are chloride, NMR and mass balance. A COA with appearance and assay but no chloride has not tested the obvious substitution.

Identity clauses for the specification

  • “Nicotinamide riboside chloride, CAS 23111-00-4, C11H15ClN2O5, molecular weight 290.70.”
  • “Assay 98.0–102.0% by HPLC, with the basis stated.”
  • “Identification by HPLC retention and UV spectrum, and by 1H NMR.”
  • “Chloride 12.0–13.0%; water ≤2.0% by Karl Fischer.”
  • “No free base or other nicotinamide above the agreed limit.”
  • “Destination market and salt form confirmed before the order.”

Questions to put to the supplier

  1. Which salt is this lot, and what CAS number appears on the certificate?
  2. Will you send the HPLC chromatogram and UV spectrum, not just the assay figure?
  3. Will you send the 1H NMR spectrum with the nicotinamide and ribose signals assigned?
  4. What is the chloride value, by which method, and what water value came from the same lot?
  5. If the lot is challenged, will you join a re-test on the retained sample?

Those five answers, taken together, form an identity file; one assay percentage does not. The product page carries the catalog specification; the COA page shows where each figure sits on the certificate; the grades page compares the salt with the free base. The tests that separate NR from NMN are on the NMN identity page; the chromatographic method is described in the HPLC note, and the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation