01 COA & batch testing

What the NAG certificate of analysis actually reports

Technical document 01 · Reviewed 2026-11-19 · N-Acetyl Glucosamine

On this page
  1. The certificate as a test report
  2. Basis, moisture and what the assay counts
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

An N-acetyl glucosamine certificate carries four kinds of evidence: appearance and identification, the HPLC assay at 98.0–102.0%, the specific rotation at +40.0° to +43.0° on the dried basis, and the remaining lines of moisture, pH, heavy metals, microbiology and particle size. Each parameter should be shown with the method used and the limit it was released against, and the lot result should be a measured value rather than a restatement of the limit. The tables below give the catalog ranges; the certificate for a given lot is what describes that pack.

In one line

The NAG certificate is read as a set: the HPLC assay counts NAG, the rotation separates it from glucosamine, and the loss on drying says how much of the powder the assay did not count.

The certificate as a test report

A COA earns its place when every line can be checked without asking the supplier what it meant. Three columns do that work: the parameter, the method that produced the number, and the release limit for the lot. A line that reads only “conforms” records a decision but not the measurement behind it. The identification lines answer what the powder is; the assay answers how much of it is there.

Release tests and limits for an N-acetyl glucosamine lot
ParameterMethodRelease limit
AppearanceVisualWhite to off-white powder
IdentificationIR and HPLC versus a referenceConforms to the reference
Assay (NAG)HPLC with UV detection98.0–102.0%
Specific rotationPolarimetry after drying+40.0° to +43.0° (dried basis)
Loss on dryingGravimetric≤1.0%
pH (5% solution)Potentiometric3.5–5.0
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 40 mesh

Basis, moisture and what the assay counts

Two lines depend on a moisture reference, and the certificate should name which one it used. Rotation is measured on the dried substance because water lowers the angle; a wet sample read without correction can fall outside the window for reasons that have nothing to do with identity. Use the loss on drying from the same test run, not a value carried over from an earlier release.

The 98.0–102.0% assay is an HPLC figure, and the catalog range does not fix its basis, so the certificate has to state one. On a dried basis, a powder that assays 99.0% as received with 0.8% loss on drying works out at 99.80% dry; on an as-received basis, the same lot reads 99.0% and the moisture is read beside it. Quotations that mix the two conventions are not comparable.

The analyte is NAG, not glucosamine. The method should name an N-acetyl glucosamine standard, the column, the mobile phase and the detection wavelength. Calling a NAG result “glucosamine 98%” mislabels the analyte even when the percentage is inside the range. The HPLC method note sets out the separation and the standard.

Release limit versus batch result

Each specification line has two numbers attached to it: the boundary the lot had to meet, and the value the laboratory actually obtained. They belong in different columns. Repeating the limit in the result column tells the reader nothing about the lot.

Limit, result and the evidence between them
ParameterRelease limitResult column
Assay98.0–102.0% by HPLCThe actual value, plus the basis and method behind it
Specific rotation+40.0° to +43.0° dried basisThe angle, the temperature and the dry basis
Loss on drying≤1.0%The percentage of water and volatiles found
pH3.5–5.0 in 5% solutionThe reading, the concentration and the temperature
Heavy metalsPer elementA mg/kg value for each metal separately
MicrobiologyCounts and absenceThe colony count plus the absence result
Particle size≥95% through 40 meshThe share that passed the sieve

A pass statement is a summary, not evidence. The reader should be able to reconstruct it from the figures: a value per metal rather than one combined total, a count and an absence statement for the microbes, and an angle with its temperature and basis for the rotation.

What moves between batches

Different process steps leave different marks on the certificate. The source — shellfish or fermentation — can shift colour, odour and minor peak patterns while the CAS number and the assay range stay the same. Crystallisation and drying change the moisture, which in turn changes the as-received assay. Milling changes only the particle-size result.

Hydrolysis is the trend specific to this molecule. At low pH or high temperature NAG can shed its acetyl group and appear as glucosamine, so a lot that was held warm or in acidic liquor may carry free glucosamine while the NAG assay still passes. The catalog does not set a free-glucosamine limit; if the market file or a stability study needs one, it is added as a named test.

When to order an outside test

Outside testing earns its place in four situations: a new source, a first consignment to a regulated market, a rotation result close to a limit, or a disputed identity. The panel should be chosen for the question, not copied from the certificate: IR and HPLC for identity, polarimetry for rotation, loss on drying, ICP-MS for the metals, microbiology, and a free-glucosamine assay if hydrolysis is suspected. For a shellfish-derived lot, the allergen statement should be checked against the source record.

Every screen should come with its detection limit. A “not detected” line without a limit says something about the method, not about the powder. Keep the tested sample as the retained sample and make sure the report carries the lot code.

What to compare between suppliers

Six lines make suppliers comparable: CAS number and source; assay value and basis; rotation with its basis; loss on drying; the metals and microbiology results; and the pack size with its lot code. If two offers agree on assay but not on source, rotation or basis, they are not offering the same powder.

Catalog ranges are published on the NAG product page; source and mesh are compared on the grades page; the analytical separation from glucosamine is on the identity page; the assay is described in the HPLC note; release is described on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation