06 Identity & adulteration

How we prove a D-mannose lot is D-mannose

Technical document 06 · Reviewed 2026-11-19 · D-Mannose

On this page
  1. The four identity layers
  2. HPLC and IR: the peak and the fingerprint
  3. The rotation is a ratio
  4. X-ray diffraction: the solid-state check
  5. What a substitution looks like
  6. How to write the identity into the specification
  7. Five questions for the supplier

A D-mannose lot passes identity only when four independent checks point the same way: the paperwork names CAS 3458-28-4 and the formula; HPLC and IR match a reference; the specific rotation sits between +14.0° and +16.0° on the dry basis; and the assay, moisture and impurity figures add up. No single number does the job. In particular, an assay percentage cannot tell D-mannose from mannitol, from glucose or from a blend.

In one line

Four independent readings have to agree before a lot is D-mannose: the record, the HPLC and IR match, the rotation, and a mass balance that closes.

The four identity layers

Paperwork is not proof. A certificate can carry the right name and still describe a different powder, so each layer below has to be answered with its own measurement. A supplier who answers only the first has sent a label, not evidence.

Four layers of D-mannose identity
LayerQuestionTestWhat it proves
RecordIs the material named?Name, CAS number, formulaPaperwork only
Chromatography and IRIs the sugar mannose?HPLC retention and IR against a referenceThe molecule, not its purity
PolarimetryWhich optical form, and how clean?Specific rotationD-form and rough purity
Mass balanceHas the powder been cut?Assay, moisture, impurity profileWhether the figures agree

HPLC and IR: the peak and the fingerprint

The method should identify the column, the mobile phase, the detector and the reference standard. Mannose has no useful ultraviolet chromophore, so the detector is usually refractive index or evaporative light scattering, or pulsed amperometry after anion-exchange separation. Refractive-index detection varies with temperature and flow, and evaporative detection is non-linear; both belong in the method note.

Retention alone is weak evidence. A peak at the expected time can be another sugar on a column that does not resolve the pair, so the method should show separation from glucose, fructose and mannitol. A spike of the sample with a reference standard, producing one larger peak, is a simple confirmation. Request the chromatogram, not only the percentage.

IR adds the fingerprint that the specification calls for. The lot spectrum should match a stored reference, not a picture in a catalogue. IR is also a practical screen for mannitol, whose spectrum differs even though the two powders look alike.

The rotation is a ratio

Specific rotation is a normalised reading: degrees divided by decimetres and by grams per millilitre of solution. That is why +15.0° with no concentration, solvent or temperature is not a specification, and why two correct certificates can still read differently.

For D-mannose the catalog range is +14.0° to +16.0° on the dry basis. Mannitol rotates at about +23° to +24° on the dry basis, so a blend of the two moves the reading upward. D-Glucose rotates at about +52.5° at equilibrium in water, so a glucose blend moves it upward more steeply. A rotation outside the range is a flag, not a diagnosis: it means the lot does not match the expected D-form and purity, and the next step is a chromatogram and a mass balance.

The rotation also catches a physical blend that was formulated to land inside the assay range. The assay sees total sugar; the polarimeter sees the weighted rotation of the mixture. Read the two together.

X-ray diffraction: the solid-state check

X-ray diffraction asks whether the solid is crystalline and whether its pattern matches a reference. It can separate a crystalline sugar from an amorphous dilution and compare two sources. It is neither a purity assay nor a counter-ion measurement; a sugar has no counter-ion.

Mannitol is polymorphic, so an XRD pattern can also distinguish its solid forms; that is a mannitol question, not a D-mannose one. For a disputed D-mannose lot, XRD plus rotation plus HPLC/IR is stronger than any one of them. XRD is not a routine release test here; a certificate that says only “XRD conforms”, with no pattern or reference, adds little. XRD helps most when the open question is solid form, not potency.

What a substitution looks like

Substitutions and the signals that expose them
SubstitutionWhat it doesSignalTest
MannitolSimilar white powder; higher rotation; non-reducingRotation above +16.0°; IR mismatchRotation, IR, HPLC
GlucoseCommon reducing sugar; rotation much higherRotation climbs toward +52.5°; extra peakHPLC with a resolving column, rotation
MaltodextrinDilution; lowers the assayAssay low; moisture or ash changeMass balance, HPLC
MoistureCaking; lowers the as-is assayLoss on drying highLoss on drying
Other sugarSimilar appearance and sweetnessRetention or IR mismatchHPLC, IR

Colour and sweetness are the weakest signals. White crystalline powder and a sweet taste cover several sugars, and a blend can be built to match both. The stronger signals are the rotation, the IR spectrum, the chromatogram and the mass balance. If a certificate shows appearance and assay but omits rotation, the most likely substitution remains unchecked.

How to write the identity into the specification

  • “D-Mannose, CAS 3458-28-4, C6H12O6, molecular weight 180.16.”
  • “Assay 98.0–101.0% by HPLC; name the detector and state the basis.”
  • “Identification by IR and HPLC against a reference; report the chromatogram.”
  • “Specific rotation +14.0° to +16.0° on the dry basis, with solvent, concentration and temperature.”
  • “Loss on drying ≤0.5%; heavy metals and microbiology as listed.”
  • “No mannitol or other sugar above the stated limit; destination market confirmed before the order.”

Five questions for the supplier

  1. Which CAS number and material name are on the certificate: D-mannose 3458-28-4 or mannitol 69-65-8?
  2. Can you provide the HPLC chromatogram and the IR spectrum, not only the assay percentage?
  3. What is the specific rotation, and under which solvent, concentration and temperature was it measured?
  4. What did this lot measure for loss on drying, and how was the assay basis worked out?
  5. If the lot is disputed, will you test the retained sample jointly with us?

Those answers, taken together, form an identity file; one assay percentage does not. The D-mannose product page publishes the catalog specification; the COA page marks where each figure sits on the certificate; the grades page describes the powder forms; the level-four comparison takes up mannitol; the HPLC method note explains how the separation works.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation