01 COA & batch testing

What the COA for D-mannose actually contains

Technical document 01 · Reviewed 2026-11-19 · D-Mannose

On this page
  1. Reading the certificate line by line
  2. What the assay, rotation and moisture are measured against
  3. Release gates and measured results
  4. Where lots differ
  5. When to test outside
  6. Comparing two suppliers

For a D-mannose lot, the certificate should let a reviewer check four things without asking a follow-up question: what the powder is, how much sugar it contains, which optical form it is, and how much water and contamination it carries. The catalog gates are IR and HPLC identification, an HPLC assay of 98.0–101.0%, a specific rotation of +14.0° to +16.0° on the dry basis, loss on drying at ≤0.5%, the heavy-metal panel and microbiology. The rotation is the line that separates D-mannose from mannitol and from several other sugars; a percentage on its own cannot.

In one line

A D-mannose certificate is complete only when the assay, the specific rotation and the loss on drying are read together, each with its method and its basis.

Reading the certificate line by line

Each parameter needs three companions: the method that produced the number, the limit it was released against, and the result itself. A line that reads only “conforms” gives the conclusion without the route to it. A result column that copies the limit is not a result.

Identity sits in two rows, not one. IR and HPLC establish that the substance is mannose; the polarimeter establishes that it is the D-form and gives a rough purity check. The assay then says how much of it is there. If any one of these is missing, the certificate describes a sugar, not necessarily this sugar.

Identity, assay, rotation and contaminants · D-mannose
ParameterMethodRelease limit
AppearanceVisualWhite crystalline powder
IdentificationIR and HPLC against a referenceConforms
AssayHPLC98.0–101.0%
Specific rotationPolarimetry, dry basis+14.0° to +16.0°
Loss on dryingGravimetric≤0.5%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

What the assay, rotation and moisture are measured against

The assay needs a stated basis. The catalog calls for 98.0–101.0% by HPLC, but the certificate should say whether the calculation uses the dried substance or the powder as weighed. On the dried basis, 98.0% with 0.5% moisture becomes 97.51% as-is, and 101.0% becomes 100.50% as-is. The label claim and the weigh-up should share whichever basis the certificate uses.

Rotation depends on path length, concentration, solvent and temperature, so the certificate should print all four beside the reading. The +14.0° to +16.0° window is tight enough that one decimal place is appropriate; a rounded integer discards the discrimination the test provides. Mannitol reads much higher, so a value outside the window is a reason to look further, not a rounding difference.

Mannose has no useful chromophore, so the laboratory usually detects it by refractive index or evaporative light scattering, or by pulsed amperometry after anion-exchange separation. “HPLC” without a detector name is only half a method. IR supplies the comparison spectrum, and the lot should be matched against a stored reference rather than a catalogue image.

Release gates and measured results

The limit is the boundary the lot must meet; the result is the number the laboratory found. They belong in different columns. “Accepted” is a summary of that comparison, not a substitute for it.

What the result column should contain
ParameterRelease limitResult column
Assay98.0–101.0% on the stated basisA measured percentage, with the basis and the detector
Specific rotation+14.0° to +16.0° dry basisThe measured figure with solvent, concentration and temperature
Loss on drying≤0.5%A measured percentage
Heavy metalsPer elementA number in mg/kg per element
MicrobiologyCounts and absenceThe count and the absence statement for the lot

For the metal panel, each element needs its own number; a summed figure hides which metal is present. For microbiology, a count and an absence statement are both required. The same logic applies to loss on drying: the measured percentage, not just “pass”.

Where lots differ

D-Mannose is made by breaking down mannan-rich plant material or by enzymatic conversion, then purifying, crystallising, drying and milling. Each step leaves a signature: colour, moisture, particle size and, slightly, rotation. A granulated lot has a different powder behaviour but the same molecule.

The rotation is worth plotting across lots. A small move inside the window can be ordinary; a move outside it points to a different sugar, a blend or a purification change. Colour is less specific. A cream tint may follow the raw material or a hot drying step, and the assay can still pass. Moisture is the clearest early warning for caking at the customer's site.

Traceability means the same lot code appears on the certificate, the pouch, the drum and the retained sample. A drift across several certificates is more informative than a single value at the edge: falling assay, rising rotation or climbing moisture is a trend worth raising with the supplier.

When to test outside

An outside laboratory earns its place when the source is new, the destination is regulated, the identity is disputed, or the supplier's certificate omits the rotation. The panel should answer the open question, not reproduce the certificate. A useful set is HPLC with the chromatogram and detector recorded, IR against a reference, polarimetry with conditions, loss on drying, ICP-MS for the metals and the microbiology panel.

If mannitol is the concern, ask for an HPLC method that resolves the two peaks and read the rotation beside it. If an unidentified sugar is present, anion-exchange chromatography or mass spectrometry can name it. Each screen should report its detection limit; a “not detected” entry without one says more about the method than the lot.

Keep the chain of custody intact. The laboratory should receive the retained sample and report the lot code. If the result is challenged, the referee needs the retained sample, the original certificate and the specification, and a test that can separate the candidate materials rather than a second run of the same assay.

Comparing two suppliers

Ask for six items in the same format: CAS number and material name; assay result with its basis; HPLC detector and IR identity; rotation with conditions; loss on drying; heavy metals and microbiology. If two offers match on assay but not on rotation or basis, they are not the same material.

Then ask for the paper trail: manufacturing site, source and route, lot number. The D-mannose product page publishes the catalog specification. The identity page sets out the tests that distinguish D-mannose from mannitol; the grades page covers the physical forms; the compliance page covers the label and the market file; the HPLC method note describes the assay; the quality page explains the release workflow.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation