01 COA & batch testing

What the COA for creatine HCl actually contains

Technical document 01 · Reviewed 2026-11-20 · Creatine HCl

On this page
  1. The certificate as a salt report
  2. Assay, creatine content and the chloride arithmetic
  3. Release limit and measured result
  4. What moves between batches
  5. When a referee laboratory earns its place
  6. Six lines for a supplier comparison

Creatine hydrochloride is a salt, not a diluted monohydrate, so its certificate has to report two different quantities: the assay of the salt and the creatine content of the powder. A working COA also carries the chloride, loss on drying, identity by HPLC and IR, the 80 mesh result, heavy metals and microbiology. The limits below are the catalog specification; the batch certificate is the record for the pack in hand.

In one line

The assay describes the hydrochloride salt, while the creatine content describes the active fraction; a COA needs both, with chloride and moisture beside them.

The certificate as a salt report

A creatine hydrochloride certificate is read in a different order from a monohydrate certificate. The identity line has to show the hydrochloride, the assay line has to state that it is calculated as the salt, and a separate line has to report the creatine content. If one of those three is missing, the reader cannot tell whether the powder is the declared salt or a blend.

The table below is the test panel for this product. Each line needs its method beside the limit; a result column that repeats the limit has recorded the gate, not the measurement.

Identity, assay and release tests · creatine hydrochloride
ParameterMethodRelease limit
AppearanceVisualWhite to off-white, free-flowing powder
IdentificationHPLC retention and IR against a referenceConforms
Assay, calculated as C4H9N3O2·HClHPLC99.0–101.0%
Creatine contentHPLC74.0–78.0%
Chloride (identity check)TitrationAbout 21.2% expected for the 1:1 salt; report the result
Loss on dryingGravimetric≤1.0%
Particle sizeSieve test≥95% through 80 mesh
Elemental impuritiesICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
Microbial loadColony count with absence checksAerobic plate count ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The IR row supports the form claim that HPLC retention cannot settle: the hydrochloride spectrum differs from the monohydrate and from free creatine. Ask for the spectrum, not only the word “conforms”.

Assay, creatine content and the chloride arithmetic

The molecular weight of creatine hydrochloride is 167.59 g/mol. Creatine accounts for 131.13 g of that mass, or 78.2%, and chloride for about 21.2%. The catalog assay is a salt assay: a 100.0% result means 100 g of hydrochloride in 100 g of powder, not 100 g of creatine. The separate 74.0–78.0% creatine line is what a formulator uses for the active mass.

The windows overlap but are not interchangeable. A lot at the top of the assay window and the bottom of the creatine window is worth querying: 100.0% salt should sit near 78% creatine before moisture. Ask whether the creatine figure is on the as-is or dried basis, and use the same basis for both lines.

Loss on drying is small here, at ≤1.0%, because this is not a hydrate. The salt is hygroscopic, though, and a result close to 1.0% leaves little room for a humid filling room or an opened pouch. A dried-basis assay without the loss on drying cannot be recalculated as-is.

Release limit and measured result

The limit is the acceptance boundary; the result is what the laboratory obtained. Separate columns, the method and the basis make a certificate auditable. A sheet that reports only “passes” removes the evidence a buyer needs to compare two lots.

What the result column should contain · creatine hydrochloride
ParameterRelease limitResult column
Assay as the salt99.0–101.0%A measured percentage, with the HPLC method and the basis
Creatine content74.0–78.0%A measured percentage, with the calculation shown
Chloride (identity)About 21.2% expectedA measured percentage and the titrant
Loss on drying≤1.0%A measured percentage
Elemental impuritiesPer elementA figure in mg/kg for each element
Particle size≥95% through 80 meshThe measured percentage through the sieve

Chloride deserves its own result, not a figure copied from the assay. It is an identity check rather than a catalog limit: 21.2% is the expected value for the 1:1 salt, and the measured result should be read beside the assay. Low chloride with normal creatine points to free creatine or monohydrate, and high chloride to added salt. It is a form check, not a purity score.

What moves between batches

Moisture moves first because the salt is hygroscopic. A pouch opened in a humid room gains water, the loss on drying rises, and the as-is assay falls while the dried-basis figure stays flat. Colour is second: white to off-white is a wide window, and a cream tint can follow drying or a longer hold. Milling and sieving set the 80 mesh result without changing the chemistry.

Chloride and pH move together when the salt stoichiometry changes: partial free base reads low chloride and a higher pH, while added chloride reads high chloride and a lower pH. Neither is visible in a nitrogen-based assay, which is why the certificate should name HPLC and titration rather than a generic “assay”.

The catalog panel does not carry creatinine or dicyandiamide. That is a statement about the specification, not proof of absence. A buyer whose formula will see heat or water should add both lines, with methods and limits, because neither is inferred from the salt assay.

When a referee laboratory earns its place

Bring in a referee laboratory for an unfamiliar source, a first shipment into a regulated market, a contested form claim, or a result that sits on a limit. The useful panel adds what the routine certificate leaves open: chloride by titration or ion chromatography, pH of a defined solution, IR, HPLC assay and creatine content with peak purity, loss on drying, ICP-MS and micro. Add creatinine, dicyandiamide or XRD only if the specification or the form claim needs them.

Request each screen's detection limit: a “not detected” entry without one says more about the method than about the powder. Preserve chain of custody by testing the retained material, and make sure the report carries the same lot code as the pouch or drum.

Six lines for a supplier comparison

Lay out six lines: form and CAS; assay as the salt and its basis; creatine content; chloride; loss on drying; mesh and pack size. Two quotations that agree on a 99% assay but differ on creatine or chloride are not the same powder. Add the metal method and the micro panel; a method-free “conforms” cannot be compared.

The second layer is traceability: the certificate should identify the manufacturer, the lot, the pack and the process route, and the code should be the same on the pouch, the drum and the retained sample.

The catalog specification sits on the creatine HCl product page. The monohydrate is a different salt with its own product page and its own release lines. The HPLC and titration methods are described in the methods section, and the quality page sets out how a lot is released. The identity page takes the chloride and pH checks further.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation