06 Identity & adulteration

How we prove a 5-HTP lot is 5-hydroxytryptophan

Technical document 06 · Reviewed 2026-11-19 · 5-HTP

On this page
  1. Four layers, four questions
  2. The ratio that exposes a blend
  3. What IR and UV show, and what XRD adds
  4. The routes that put the wrong material in the drum
  5. Writing identity into the specification
  6. Five questions for a supplier

A 5-HTP lot is 5-hydroxytryptophan when four independent lines agree: the document names the material and its source, IR and UV match the reference, the HPLC assay and related-substance profile fit the specification, and the source record explains the impurity pattern. The assay percentage alone does not prove identity; a tryptophan blend and a diluted extract can both be made to pass a number.

In one line

Identity is a stack, not a percentage: the spectra, the chromatogram, the lot record and the source have to point at the same material.

Four layers, four questions

Evidence layers for a 5-HTP lot
LayerEvidenceWhat it establishesLimit of the evidence
DocumentName, CAS 56-69-9, source, manufacturer, lot codeThe claimed identity and the chain of custodySays nothing about the material itself
StructureIR and UV against a referenceAn indole amino acid with this substitution patternCannot quantify a second indole
Separation and quantityHPLC assay and related substancesAmount present and the surrounding peak patternCannot distinguish plant from synthetic origin
SourceManufacturer declaration and lot recordWhich production route the lot followedDepends on the declaration being accurate

The order matters. A document without a spectrum leaves the structure open; a spectrum without a related-substance panel leaves the purity open; a chromatogram without a source record leaves the route open. Only the four together describe the material.

The document layer is where most purchasing files stop: a certificate with a name and a CAS number is read as identity. It is the weakest layer, because it repeats what the seller typed. The source record strengthens it only when the manufacturer is named and the lot code can be followed to a packing record. The spectra and the chromatogram are what the buyer can re-run.

The ratio that exposes a blend

5-HTP and tryptophan differ by one oxygen: 220.23 against 204.23 g/mol. On a chromatogram the two elute at different times, and a related-substance method that resolves them gives a ratio between the 5-HTP peak and the tryptophan peak. In a clean synthetic lot that ratio is large; in an extract it reflects the plant matrix and the purification; in a blend it moves toward the second material. The ratio is a fingerprint, not a limit on its own.

Mass balance gives a second check. Assay, loss on drying, residue and related substances should account for the whole powder. A lot whose assay is high while the other three lines are small leaves a gap that the certificate has not named. The gap is a question, not a rejection.

What IR and UV show, and what XRD adds

IR identifies the functional groups: the indole N–H, the carboxylate and the hydroxyl that distinguishes 5-HTP from tryptophan. UV sees the indole chromophore, with an absorption in the 270–280 nm region, and a diode-array detector compares the peak's spectrum with the standard. The catalog identity is “IR and UV conform”, and both should be run against a reference spectrum on the same instrument.

X-ray diffraction answers a different question. It describes the solid state — whether the powder is crystalline, and whether a second crystalline phase is present. It is not the primary identity test for 5-HTP, and a clean diffraction pattern does not prove the molecule; it is an additional check when a blended or recrystallised lot is suspected. The XRD note explains what the technique can and cannot see.

The routes that put the wrong material in the drum

Substitution routes and the evidence that detects them
SubstitutionSignal in the dataRequest
Tryptophan added or substitutedA tryptophan peak at mass 204 shifts the peak ratioIndividual related substances with limits
Other indole speciesUnnamed peaks, colour drift, assay below rangeLC-MS identification of the unknown peak
Sugar or salt diluentMoisture or residue high, assay lowMass balance from one sample
Synthetic sold as GriffoniaSpectra and assay agree, source record does notManufacturer declaration and plant record
Wrong stereoisomerIdentical UV and mass, different optical rotationSpecific rotation or chiral HPLC
Relabelled old stockColour and total impurities move; packing date oldLot record, packing date, retained sample

The most direct substitution is tryptophan, because it is structurally close and widely traded; it shows as an extra peak and a changed ratio. A sugar or salt diluent shows in the residue, the loss on drying and the assay. The source substitution is the hardest: once both materials are at 98%, the assay cannot tell, so the source declaration, the manufacturer and the lot record carry the question.

Writing identity into the specification

Write seven lines: name with source and CAS 56-69-9; identification by IR and UV; assay by HPLC at 98.0–101.0% on the dried basis; related substances with individual and total limits, method and quantification limit; loss on drying ≤0.5%; residue on ignition ≤0.1%; metals, micro and particle size. Add specific rotation or chiral HPLC if the stereoisomer is part of the claim.

Two of those lines are identity, one is quantity, one is purity, and three are physical or contaminant. A specification that says “98%” and nothing else describes a number, not a material.

If the lot is an extract, the specification should also name the extraction solvent and the carrier, because both can appear in the chromatogram. If it is synthetic, name the route and the solvents. Identity is not only the molecule; it is the molecule plus the process that made it.

Five questions for a supplier

  1. Who manufactured the lot, and is the source Griffonia extract or synthetic?
  2. Can you provide the IR and UV spectra against a reference, not only a “conforms” line?
  3. What are the individual and total related substances, the method and the quantification limit?
  4. Is the stereoisomer specified, and how is it measured?
  5. Does the lot code match on the certificate, the pack and the retained sample?

The catalog specification is on the product page; the certificate lines are on the COA page; the source choice is on the source page; the infrared method is described in the FTIR note.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation