01 COA & batch testing

Reading a phycocyanin COA: pigment, protein and the batch result

Technical document 01 · Reviewed 2026-11-19 · Phycocyanin

On this page
  1. The certificate as a test report
  2. UV/Vis, Kjeldahl and the two bases
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

A phycocyanin certificate has to do two jobs at once: show that the blue pigment is present and put a number on the protein it sits in. The lines that carry the argument are the UV/Vis identification, the pigment percentage with its wavelength pair, the Kjeldahl protein with its nitrogen factor, moisture, ash and the contaminant panel. The limits below are the catalog gates; the results that sit beside them belong to one lot.

In one line

The blue colour is the identity, the UV/Vis figure is the pigment and the Kjeldahl figure is the protein; a certificate that reports only one of them has not described the powder.

The certificate as a test report

Every line should be traceable to a method and a limit. When a reviewer cannot see how a number was produced, the certificate stops being a test report and becomes an assertion. The three columns below are the minimum: what was tested, how, and the gate the lot had to meet.

Identity, pigment, protein and contaminants · phycocyanin
TestMethodRelease limit
AppearanceVisualBlue, free-flowing powder
IdentificationUV/Vis spectrum, 500–700 nmAbsorbance maximum near 620 nm; conforms to the reference
PhycocyaninUV/Vis at 620 nm with turbidity correction≥25.0%
ProteinKjeldahl, nitrogen × 6.25≥50.0%
MoistureLoss on drying, gravimetric≤7.0%
AshGravimetric, ignition≤8.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

UV/Vis, Kjeldahl and the two bases

The pigment result is a spectrophotometric reading. C-phycocyanin absorbs most strongly near 620 nm, and the laboratory reads that wavelength plus a second reading at 650 nm to subtract turbidity. Dilution, cell path length, the calibration standard and the reporting basis all move the number, so a percentage quoted without them cannot be reproduced in another laboratory.

Protein is a separate measurement. Kjeldahl digestion converts the nitrogen to ammonia, and the result is multiplied by 6.25. Because phycocyanin is itself a protein, the pigment counted in the first line is part of the protein counted in the second: the 25.0% minimum sits inside the 50.0% minimum. The remainder is other soluble protein, not a separate ingredient, and the two figures are neither additive nor a cross-check on each other.

Moisture connects the two lines. The 7.0% gate is measured by loss on drying, and the pigment result can be stated as-is or on the dry basis. A lot at 26.0% as-is with 6.0% moisture works out to 27.66% dry. Both numbers can be honest, but a buyer comparing certificates has to know which basis the supplier printed.

Release limit versus batch result

A specification line has a gate and a measurement, and the certificate should keep them in separate columns. If the result column simply repeats the gate, the reader learns nothing about the lot.

What the result column should contain
TestRelease limitWhat the result column shows
Phycocyanin≥25.0% by UV/VisA measured percentage, with the wavelength pair and the basis
Protein≥50.0% by KjeldahlA measured percentage and the nitrogen factor used
Moisture and ash≤7.0% and ≤8.0%Two measured percentages
Heavy metalsPer elementA measured figure in mg/kg for each element
MicrobiologyCounts and absenceA count plus the absence statement for the lot

Heavy metals are reported per element for a reason. A single total hides which metal is present, and the destination limits differ by element. In the same way, a microbiology line that says “absent” without the test method and the sample size is weaker than a count plus an absence statement. The evidence should let the reader reconstruct the release decision.

What moves between batches

Cultivation is the first source of variation. Light, nitrogen supply and the harvest point change how much pigment the biomass carries, and the drying step decides how much of that colour survives. A freeze-dried lot and a spray-dried lot from the same harvest can differ in shade and in the pigment percentage, even when the protein figure barely moves.

Ash follows the culture medium and the wash. A result near the 8.0% gate points to residual salts rather than to a pigment problem, and it is worth asking whether the wash step changed. Milling sets the 80 mesh figure; a new mill or a new sieve can move that line without touching the chemistry.

Appearance is the coarsest line on the page. Blue covers a wide range, and a greener or duller lot can mean chlorophyll carry-over, heat damage or a different dry. A photograph is not a release test. Read the measured pigment and the spectrum, and ask for the batch record when the shade moves outside its usual band.

When to order an outside test

An independent laboratory is worth the cost when the source is new, the destination is regulated, the colour is a label claim, or a result is disputed. Choose the panel to answer the doubt rather than to repeat the certificate. A full scan from 500 to 700 nm, an HPLC screen for synthetic blue dyes, Kjeldahl protein, ash and ICP-MS cover most of the arguments that arise with a blue powder.

Ask for the detection limit of every screen. A “not detected” entry without a limit describes the method, not the sample. Keep the chain of custody intact: the material tested should be the material retained, and the report should name the lot. If a result is contested, send the retained sample, the supplier's certificate and the specification to the referee, and ask for the tests that separate a pigment concentrate from a dyed powder.

What to compare between suppliers

Six lines make a fair comparison: source and strain; pigment result with wavelength pair and basis; protein result with nitrogen factor; colour and appearance; moisture, ash and contaminants; pack size and lot code. Two offers that both say 25% but use different methods or bases are not the same powder.

Traceability is the second layer. The certificate should identify the manufacturer, the culture and the drying step, and the milling route. The product page holds the catalogue values; the identity page explains how the spectrum and the protein figure are read; the grades page covers the format choice; the methods library has the spectrophotometric note; the quality page describes the release file.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation