01 COA & batch testing

What the COA for peanut protein peptides actually contains

Technical document 01 · Reviewed 2026-11-19 · Peanut Protein Peptides

On this page
  1. The certificate as a test report
  2. The nitrogen factor, the peptide cut-off and the basis
  3. Release limit, catalog range and lot result
  4. What moves between lots
  5. When an outside test earns its fee
  6. What to compare between suppliers

A peanut protein peptide certificate reports appearance, protein by Kjeldahl, peptide by HPLC, ash, moisture, heavy metals, microbiology and particle size. Protein and peptide each need their method, the nitrogen factor and basis for protein and the HPLC cut-off for peptide, and the allergen statement belongs on the same document.

In one line

A peanut peptide COA is read as agreeing measurements: protein with its nitrogen factor and basis, peptide with its HPLC cut-off, ash beside sodium, and a peanut allergen statement that matches the pack.

The certificate as a test report

A certificate earns its place when each line can be checked: the parameter, the analytical method, the release limit and the measured result. “Conforms” on its own is a verdict without the working.

Composition, contaminants and physical parameters · peanut protein peptides, catalog limits
ParameterMethodRelease limit
AppearanceVisualOff-white to light tan powder
ProteinKjeldahl≥80.0%
Peptide contentHPLC peptide distribution≥70.0%
AshGravimetric, furnace≤5.0%
MoistureLoss on drying≤7.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh
Peanut allergenDocument reviewPeanut declared; source named

Comparability starts with the method column: Kjeldahl protein and HPLC peptide are not the same kind of number, and the allergen line is a document check rather than an analytical result.

The nitrogen factor, the peptide cut-off and the basis

Kjeldahl measures nitrogen and multiplies it by a factor. Peanut protein is customarily calculated with 5.46, while the general 6.25 factor is also used. On the same nitrogen result, 6.25 reports about 14% more protein than 5.46; an 80.0% figure by 6.25 is about 69.9% by 5.46. The factor must be printed beside the figure, because two certificates on different factors do not describe the same powder.

The basis is the second half. The catalog sets protein at ≥80.0% and moisture at ≤7.0%; a dry-basis result of 80.0% at the moisture ceiling is about 74.4% as-is, a material difference at a release gate. The certificate should state the basis.

Peptide content is a separate measurement. The HPLC distribution separates the peptide fraction from larger proteins, free amino acids and salts, and the result depends on the cut-off. The peptides are part of the protein, so 80% protein and 70% peptide do not add to 150%; at the minima the peptide fraction is at least 87.5% of the protein figure on the same basis. The gap holds free amino acids and non-peptide solids.

Ash is the mineral load. pH adjustment during extraction and hydrolysis leaves salt on neutralisation; ash near 5.0% with high sodium is consistent with salt, while high ash with low sodium points to another mineral source or a carrier. Moisture at ≤7.0% is a release gate, not a storage allowance, and it moves the as-is figures.

The allergen statement should name the source and the allergen, not only say “allergen: see label”. Hydrolysis changes the protein profile, not the source; the declaration follows the peanut.

Release limit, catalog range and lot result

A catalog range describes what the grade is sold to meet, a release limit is the tighter gate agreed for a customer or market, and the lot result is what the laboratory actually found. The first two are promises; the last is evidence.

What the result column should contain
ParameterCatalog limitResult column
Protein≥80.0%A measured percentage with the factor and the basis
Peptide≥70.0%A measured percentage with the HPLC cut-off and integration range
Ash≤5.0%A measured percentage, with sodium if the salt load is in question
Moisture≤7.0%A measured percentage
Heavy metalsPer elementA figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot
Particle size≥95% through 80 meshThe measured percentage through the sieve

If the result column simply restates the limit, the certificate has not reported a measurement. Microbiology needs a count and an absence statement; heavy metals need one figure per element. The allergen statement is a controlled document and should carry a version and the lot.

What moves between lots

The raw material is peanut, and peanut is agricultural. Variety, region and season move the protein, ash and aflatoxin risk, and hydrolysis can only work with what arrives. A different crop year is not a process change, but it can move the colour and the peptide distribution.

The hydrolysis step moves the peptide figure. Enzyme choice, dose, time, pH and temperature set the degree of hydrolysis; a longer or more active hydrolysis shifts the distribution toward smaller peptides and can raise the peptide content while the protein figure stays inside its window. The same step can raise bitterness and, where pH is adjusted, the salt load. Drying moves moisture, colour and flow, and milling moves the sieve result.

Colour is the least numerical line, and it can still be informative. Off-white to light tan leaves room; a darker shade inside that range is not an identity failure. It can, however, point to a hotter dryer, a longer hold or a Maillard reaction while the protein figure passes. Check that the lot code on the certificate appears on the pouch, the drum and the retained sample.

When an outside test earns its fee

An outside test is worth ordering for a new source, a first shipment into a regulated market, or a result the supplier and buyer cannot agree. Repeat only what answers the open question: protein with its factor at a second laboratory, peptide by HPLC with the cut-off, amino acid profile, ash and sodium, heavy metals, microbiology, and aflatoxin B1 and total.

Aflatoxin sampling is easy to get wrong. Contamination is not evenly distributed through a peanut lot, so a small grab sample can miss a hot spot. Ask for the sampling plan, sample size and detection limit. Ochratoxin A belongs where the destination sets a limit.

For identity, add peanut-specific PCR or an ELISA for a peanut allergen. A negative ELISA after hydrolysis does not prove the material is not peanut-derived; the epitope may have been cleaved. The declaration follows the source. The laboratory should test the retained sample, and the report should name the lot.

What to compare between suppliers

Put seven lines side by side: protein with its factor and basis; peptide with the HPLC method and cut-off; ash with sodium; moisture and particle size; aflatoxin results with the sampling plan; the peanut allergen statement; and traceability from certificate to pack. Two quotations can both say 80% protein and still describe different powders if the factor or the peptide method differs.

The protein and peptide figures separate the grade from intact peanut protein; ash and sodium show the salt load; aflatoxin separates a controlled lot from an uncontrolled one. The catalog specification is listed on the peanut protein peptide product page. The identity page explains the tests that separate the peptide from the parent protein; the HPLC method note covers the separation; the quality page describes release.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.