How to prove a lot is peanut protein peptides
A peanut protein peptide lot is identified when the protein figure, the peptide distribution, the ash and sodium, and a peanut-specific check agree. The certificate name is the weakest layer: another protein can meet a Kjeldahl figure, and another hydrolysate can meet a peptide figure. The source and the allergen statement are part of the identity, not only the label.
Identity is a set of agreeing measurements: protein with its factor, the peptide distribution, ash and sodium, and a peanut-specific check that the source is what the label says.
The five identity layers
One number cannot carry the identity on its own. Another protein can satisfy the Kjeldahl figure, another hydrolysate can satisfy the peptide figure, and a dye can imitate the colour. The layers below are separate questions, and each needs its own evidence.
| Layer | Question | Test | What it proves |
|---|---|---|---|
| Document | Is the material and source named? | Name, source, lot, allergen statement | Paperwork and traceability only |
| Protein | Is the nitrogen from peanut protein? | Kjeldahl with factor and basis; amino acid profile | The protein quantity, not the source |
| Peptide | Is it a hydrolysate? | HPLC peptide distribution with the cut-off | The fraction, not the parent protein |
| Source | Is it peanut? | Peanut-specific PCR; ELISA for Ara h 1 or Ara h 2 | A peanut marker, within the test's limits |
| Mass balance | Is it diluted or salted? | Ash, sodium, moisture, protein and peptide figures | Consistency of the numbers |
The document layer records what was intended; it cannot show what was made. The other four layers are the evidence, and they have to agree.
The protein-to-peptide ratio and the ash pair
Read protein and peptide on the same basis. At the catalog minima, 80% protein and 70% peptide mean the peptide fraction is at least 87.5% of the protein figure; the peptide is part of the protein, so the numbers overlap rather than add.
A high protein figure with a low peptide figure points to intact peanut protein, a coarse hydrolysate or non-protein nitrogen. A high peptide figure with a low protein figure is arithmetically limited; check the methods and the bases before accepting it. A lot at 80% protein and 60% peptide is not the catalog grade, whatever the label says.
Ash and sodium are the second pair. Ash is ≤5.0%; a high ash with high sodium is consistent with salt from pH neutralisation, while a high ash with low sodium points to another mineral or a carrier. Moisture closes the mass balance: protein, ash, moisture and fat should account for the powder, with the peptide inside the protein figure, and a gap is a question. The ratio is a consistency check, not a purity measure.
What XRD can and cannot show
Peanut peptides are amorphous. A diffractogram shows a broad halo and no crystalline peaks, so XRD cannot identify the peptide or separate it from a soy or pea peptide.
It can show a crystalline salt. Sodium chloride from neutralisation is crystalline, and a powder that shows halite peaks has a salt phase that the ash figure alone would not distinguish from other minerals. It can also show a crystalline carrier such as lactose or sorbitol; amorphous maltodextrin is invisible to XRD.
Use XRD as a screen when ash or sodium is high or a carrier is suspected, not as a release test. Before accepting a “match” statement, ask for the reference pattern and the limit of detection.
What adulteration looks like
| Route | Marker | Test |
|---|---|---|
| Other plant protein (soy, wheat, pea) | Protein and peptide may pass; amino acid profile shifts; no peanut DNA | Amino acid profile; peanut-specific PCR; allergen ELISA |
| Intact peanut protein or meal | Peptide low for the protein figure; large proteins in the distribution | HPLC peptide distribution |
| Free amino acids | Peptide low; free amino nitrogen high | Amino acid profile; HPLC |
| Non-protein nitrogen (melamine, urea) | Protein high; amino acids low | Kjeldahl plus amino acid profile; melamine and cyanuric acid screen |
| Carrier dilution (maltodextrin) | Protein and peptide down; ash may rise; XRD halo | Mass balance; declared carrier; label |
| Salt from neutralisation | Ash and sodium high; protein and peptide normal | Ash, sodium, XRD (halite) |
Melamine is about 67% nitrogen by mass, so a small addition lifts the Kjeldahl figure without adding peptide. Urea does the same on a smaller scale. Neither is caught by a protein result; both are caught by the amino acid profile and a targeted screen. For peanut, species-specific PCR and allergen ELISA are useful, but hydrolysis degrades DNA and cleaves epitopes: a negative result does not prove absence, and the declaration follows the source.
How to write identity into the specification
- “Peanut protein peptides (peanut); source and allergen statement.”
- “Protein ≥80.0% by Kjeldahl, factor 5.46, basis stated.”
- “Peptide ≥70.0% by HPLC, cut-off and integration range stated.”
- “Ash ≤5.0%; sodium reported; moisture ≤7.0%.”
- “Particle size ≥95% through 80 mesh.”
- “Aflatoxin B1 and total aflatoxin limits; sampling plan stated.”
- “No undeclared carrier, diluent or added amino acid.”
- “Peanut-specific check on request; lot code and retained sample.”
A specification that names only the material leaves the two central numbers and the source untested.
Five questions for the supplier
- Which peanut source and which allergen statement does this lot carry?
- What are the protein factor and basis, and what is the HPLC cut-off for the peptide figure?
- What are the ash and sodium results, and is any carrier declared?
- Can you supply the aflatoxin results and the sampling plan for this lot?
- If the lot is disputed, will you run a joint re-test on the retained sample?
Five specific answers build an identity file; one protein percentage does not. The catalog specification is on the product hub; the COA page maps each figure; the grades page covers the specification axes; the compliance page covers the allergen file; the methods section describes the HPLC, ICP and PCR methods; the quality page covers the retained sample.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation