What the COA for pea protein isolate actually contains
Three groups of numbers decide what a pea protein isolate certificate means: the protein figure with its nitrogen factor and basis, the moisture, ash and fat that make up the rest of the powder, and the contaminant and microbiology results that release the lot. The catalogue sets the windows; the batch certificate reports what the drum measured.
A pea isolate certificate is only complete when the protein figure carries its nitrogen factor and dry basis, and the moisture, ash and fat limits sit beside the lot results they qualify.
What the certificate reports
Pea protein isolate is not a single molecule, so CAS 90082-22-5 identifies the material rather than an assay. The certificate describes the powder: the protein, the water, mineral and fat beside it, its behaviour in suspension, and the contamination tested. The limits below are the catalogue values; each shipment repeats them against the result for that drum.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Light yellow to cream powder |
| Protein | Kjeldahl, N × 6.25 | ≥80.0% (dry basis) |
| Moisture | Loss on drying | ≤8.0% |
| Ash | Gravimetric, furnace | ≤5.0% |
| Fat | Solvent extraction | ≤2.0% |
| pH (5% suspension) | Potentiometry | 6.0–8.0 |
| Particle size | Sieve | ≥95% through 80 mesh |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and enrichment | APC ≤10,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent |
Source is part of the description even when it yields no number. The certificate should name yellow pea (Pisum sativum) seed and the process, because a concentrate made by air classification is a different ingredient. The identity page sets out how that claim is tested.
The nitrogen result and its multiplier
Kjeldahl measures nitrogen, and 6.25 is the general food factor used here: it assumes nitrogen is 16% of protein. An 80.0% dry-basis figure therefore corresponds to about 12.8% nitrogen. The multiplier is an agreed convention rather than an analytical result; a certificate that leaves it out, or leaves out the basis, cannot be set beside one that names both.
The denominator is the other half of the figure. The 8.0% moisture limit keeps water out of it. At that limit, 80.0% dry basis is 73.6% as-is, because 8% of the powder is water. Mix the two bases on a label or a purchase order and the figure is out by 6.4 points before any laboratory variation enters.
Ash at ≤5.0% and fat at ≤2.0% are not side issues. Ash covers the minerals left by extraction and neutralisation, fat covers the residual oil, and both dilute the protein when they rise. A lot at 80.0% protein with 5.0% ash and 2.0% fat is a different powder from one at 85% protein with the same ash and fat, though both can meet a specification written as “80% pea protein”.
Limit, result and what a pass means
A release limit is the boundary the specification draws; a lot result is the number the bench returned for that drum. “Conforms to specification” is a verdict with no figures attached. The useful line prints the limit, the result, the method and the test date together, and for protein it also shows the nitrogen result so the arithmetic can be checked.
Particle size is a case in point: the ≥95% through 80 mesh figure is a pass or fail gate, while the distribution behind it is a description, and two lots that pass the sieve can still differ in dust, flow and wetting. pH 6.0–8.0 in a 5% suspension is a gate on the process. Heavy metals at Pb ≤3, As ≤2, Cd ≤1 and Hg ≤0.1 mg/kg, and microbiology at APC ≤10,000 cfu/g with E. coli and Salmonella absent, are release gates rather than targets.
Everything here describes the catalogue, not a production run. The certificate is what turns those ranges into a statement about one drum, and this site does not reproduce a lot result, a batch number or a customer. The COA glossary entry defines the document.
Why lots differ
Pea protein moves between lots for reasons mostly upstream of the dryer. Variety, growing season and soil decide the protein and the mineral load in the seed. Extraction pH, wash steps and the precipitation point decide how much ash and fibre travel with it. Drying temperature and residence time decide colour and how much powder passes 80 mesh.
A floor at 80.0% leaves room for the lot to sit above it; the certificate result shows where. Colour drifts with season and drying, and the appearance line is written broadly for that reason. Dispersibility and taste move too, and neither is fully captured by the certificate, which is why the retained sample matters when a lot behaves differently in the trial.
When an outside test is worth it
Bring in an outside laboratory when the supplier is new, when the first commercial lot is entering a regulated market, or when the label makes a statement the certificate cannot prove. The tests should close the open question, not duplicate the certificate: the amino acid profile and a non-protein nitrogen check for identity, PCR or ELISA for soy, wheat and other legumes, ICP-MS for the four metals, and a plate count for microbiology.
A dispute is settled the same way: send the retained sample, the certificate and the agreed specification, and ask for the tests that narrow the explanation. A protein result alone will not say whether a low figure came from the raw pea, from over-washing or from a blend. The quality page covers the batch file and the ICP-MS method note the metal panel.
Six lines to compare
An offer is comparable only when six lines are on the table: the protein figure with its factor and basis, the moisture, ash and fat limits, the particle size and method, the allergen statement for pea and for any shared line, the origin and process, and lot traceability from certificate to drum to retained sample. Agreement on “80% protein” with disagreement on the other five lines means the two offers are for different materials.
The paperwork has a second layer: which site made the lot, which pea batch went in, which extraction and drying conditions applied, and what sample was retained. The certificate can be genuine and still belong to another drum; the lot number has to match on the COA, the pack and the retained sample.
The ranges are on the product page; the grade decision is on the grade comparison, and the tests that prove the material are on the identity page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation