02 Grade comparison

Low-iron or iron-saturated lactoferrin: choosing a grade

Technical document 02 · Reviewed 2026-11-19 · Lactoferrin

On this page
  1. Why there is more than one grade
  2. What changes across the band
  3. The physical form is the other half of the grade
  4. The dosage form decides which grade fits
  5. What changing the grade changes in the file
  6. When the catalogue band is enough

Lactoferrin is quoted in more than one iron-saturation band, and the band changes the colour, the iron carried per gram and the way the powder behaves in a hot process. The catalogue band is 9.0–20.0% iron saturation at protein ≥95.0%; a low-iron grade and a saturated grade can be agreed on request. The grade is a specification decision, not a different substance.

In one line

The grade is the iron saturation band, the protein figure and the physical form together; changing it changes the colour, the iron per gram and the evidence the stability file has to carry.

Why there is more than one grade

Bovine lactoferrin leaves the milk partly loaded with iron, and the natural spread is wide enough that a supplier has to set a band before the powder can be sold. The catalogue band of 9.0–20.0% brackets that spread and needs no loading or stripping step, which is why it is the default grade. The protein in it is the same protein that appears in the other two grades.

A low-iron grade is agreed below the 9.0% floor. The supplier strips iron from the protein, and the certificate carries the lower limit that was agreed rather than the catalogue range. A saturated grade is agreed near full occupancy: the sites are loaded rather than emptied, and the certificate carries the higher figure the site can hold. Both are lactoferrin by identity, and both carry the same CAS number and the same milk allergen.

The grade name is therefore a description of the iron load, not of the protein. A buyer who specifies only “lactoferrin” has specified the protein and left the iron band open, which is the parameter that most affects what the powder looks like and how it behaves in the process.

What changes across the band

Grade comparison · what the iron band changes
PointCatalogue 9.0–20.0%Low-iron, agreedSaturated, agreed
Iron per gramAbout 0.13–0.28 mgBelow the bandAbove the band, toward 1.4 mg
ColourPinkish-white to light tanPalest of the threeDeeper pink to tan
Heat behaviourPartly loaded; intermediateLeast tolerant of heatMost tolerant of heat
SolutionClear to slightly hazy, pale pinkPaler; check hazeMore colour; check haze
Iron on the labelSmall and calculableSmallerLarger
Certificate line9.0–20.0%Its own upper limitIts own lower limit

The heat row is the one that decides most processes. The apo form, with its sites empty, unfolds at a lower temperature than the loaded form; a low-iron grade sits closer to that end of the scale, so it is the least forgiving of a hot step and the saturated grade the most forgiving. That is a behaviour of the molecule, not a claim about what it does in the body, and it belongs in the process risk assessment rather than in the marketing copy.

The physical form is the other half of the grade

All three iron grades are spray-dried powders milled to ≥95% through 80 mesh, which puts most particles below about 177 µm. The fine powder blends well and fills capsules well, and it is also dusty and quick to pick up moisture, so the pack and the room humidity matter as much as the mesh.

A granulated form can be agreed on request. Granulation changes the particle size, the flow and the dust, and it can change how the powder disperses in water; it does not change the iron saturation or the protein figure. If the application is a stick pack or a blend that must not segregate, the granulated form is worth asking about, and the certificate should still carry the same identity, protein and iron lines.

The dosage form decides which grade fits

A capsule is the simplest case. The fill weight is small, the powder is enclosed, and a clear shell shows the colour of the grade, which is why a capsule product often specifies the catalogue band and accepts the lot-to-lot colour drift that comes with it. A low-iron grade gives a paler shell; a saturated grade gives a deeper one. Neither changes the fill weight.

A tablet needs flow and compression, so a granulated grade is more likely than a fine milled one, and the iron band is secondary to the granulation. A stick pack or a drink mix puts the powder in water, where the grade shows in the colour and the haze of the drink. A ready-to-drink product adds a heat step, and that is where the saturated grade earns its place: it tolerates the process better than the low-iron form.

The form also sets the moisture protection. A foil pouch or a sealed stick keeps the 5.0% moisture limit; a capsule in a loose bottle does not, and the grade cannot compensate for a weak pack.

What changing the grade changes in the file

Switching the iron band changes four lines on the specification: the iron saturation limit and its method, the appearance wording, the calculated iron contribution per gram, and the stability data that has to be generated on the grade actually sold. It does not change the identity tests, the protein limit, the moisture and ash limits, the contaminant panel, the mesh or the milk allergen statement.

The stability file is the line buyers forget. A shelf life generated on the catalogue band does not automatically transfer to a saturated grade, because the two forms behave differently under heat and moisture. The supplier should be able to say which grade was on stability and for which pack. The stability page sets out what the protocol has to cover.

Write the grade into the product name on the purchase order, not only into a note. “Lactoferrin, iron saturation 9.0–20.0%, protein ≥95.0%” and “lactoferrin, low iron” are different specifications, and a certificate issued against the first will not support a label built on the second.

When the catalogue band is enough

Most dry blends and capsules do not need a special band. If the process has no hot hold, the pack keeps moisture out, and the label does not build a story on iron, the catalogue range gives the widest supply and the fewest qualification steps. A special grade adds a production step and a stability file, and it should be chosen because the process or the label needs it, not because it sounds more precise.

For the arithmetic behind the percentage, see iron saturation in lactoferrin. The certificate lines are on the COA page, the label consequences are on the compliance page, and the catalogue ranges are on the product page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.