01 COA & batch testing

What a bovine colostrum certificate reports

Technical document 01 · Reviewed 2026-11-19 · Colostrum

On this page
  1. The certificate as a test report
  2. The protein factor, the IgG method and the moisture basis
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

The certificate for a colostrum lot reports appearance, protein by Kjeldahl, IgG by radial immunodiffusion, fat, lactose, moisture, heavy metals, microbiology and particle size. Each line carries its method and its release limit, and the measured result sits in its own column. The limits in the tables below are the catalog specification; the batch COA is the document that confirms one pack.

In one line

A colostrum certificate is read in two layers: the protein figure needs its nitrogen factor, and the IgG figure needs the immunodiffusion method beside it.

The certificate as a test report

A certificate is worth reading closely when it can be audited line by line. Each parameter needs the analyte, the method behind the number and the limit the lot was judged against. A row that offers only “conforms” hands the reader a verdict in place of the evidence, and this is a material where that shortcut costs money.

Two rows decide the material. The protein row says how much protein is in the powder; the IgG row says how much immunoglobulin survived the process. They are measured by different techniques, and they can move in opposite directions.

Identity, protein, IgG, fat, lactose and release limits · colostrum powder
ParameterMethodRelease limit
AppearanceVisualOff-white to light tan, free-flowing powder
ProteinKjeldahl nitrogen × 6.38≥70.0%
IgGRadial immunodiffusion≥20.0%
FatSolvent extraction≤5.0%
LactoseEnzymatic or HPLC≤5.0%
MoistureLoss on drying≤7.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

The protein factor, the IgG method and the moisture basis

The protein figure is a nitrogen figure multiplied by a factor. For milk and milk products the convention is 6.38 rather than the 6.25 used for most plant proteins, because nitrogen is not quite 16% of the mass of milk protein. The gap matters: 70.0% on the 6.38 factor reads 68.6% on 6.25 from the same nitrogen result. The certificate should print the factor beside the protein row, and the specification should name it.

The IgG figure is a percentage of the powder as received. A lot at 5.0% moisture carries 21.1% IgG on the dry basis, so a comparison between two certificates is valid only when both are on the same basis. The as-is basis is the commercial one, because it is what the capsule is filled with.

Radial immunodiffusion is not a total-protein test. The sample diffuses into an agarose gel that contains antibody raised against bovine IgG, a precipitation ring grows, and the ring diameter is read against a standard curve. A partly unfolded IgG can fail to precipitate, so the result follows the drying and holding history of the lot as well as its composition.

Read the two rows together. At the catalog limits, 20.0% IgG against 70.0% protein is a ratio of about 0.29, and that ratio is the quickest sanity check on a certificate. A powder that reports 70% protein and 5% IgG is not the same material at a lower assay; it is a different fraction.

Release limit versus batch result

Two numbers belong in two columns. The limit is where the lot had to sit to be released; the result is what the laboratory found in that particular pack. Collapsing them into one column turns the certificate into a copy of the specification, and the reader loses the only evidence the document exists to carry.

What the result column should contain
ParameterRelease limitResult column
Protein≥70.0% by Kjeldahl, factor statedA measured percentage and the factor used
IgG≥20.0% by radial immunodiffusionA measured percentage, the standard and its lot
Fat and lactoseFat ≤5.0%; lactose ≤5.0%A measured percentage for each
Moisture≤7.0%A measured percentage
Heavy metalsPer elementA figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot

“Passes specification” is a conclusion the reader should be able to reach from the numbers. For IgG that means a percentage plus the method and the standard; for microbiology a count and an absence statement; for heavy metals a figure per element rather than a single total.

What moves between batches

Colostrum is a collected raw material, and the collection varies. The season, the parity of the cow, the interval between calving and the first milking and the herd all move the IgG and the protein in the raw fluid. Manufacturers meet a fixed specification by blending lots, so the certificate describes the blend rather than the raw collection.

Process steps move the other lines. Skimming sets the fat, lactose reduction or ultrafiltration sets the lactose, and the dryer sets the moisture and the colour. The 80 mesh figure is a finishing specification: it changes when the mill or the sieve changes, without any change in the chemistry.

IgG deserves a trend chart. One result just above the limit is a release, but three lots drifting downward point to a drying step, a hold time or a raw-material selection worth a conversation before the next order.

When to order an outside test

Order an independent test for a new source, a first shipment into a regulated market, a grade claim the supplier's certificate does not prove, or a disputed result. The useful panel is not a full repeat. It is IgG by radial immunodiffusion with the standard named, protein by Kjeldahl with the factor, fat, lactose, moisture, ICP-MS for the heavy-metal panel, microbiology and a species check on the protein.

A second IgG method is worth the cost when the number is the claim. An ELISA and a radial immunodiffusion assay can disagree because the two antibody systems see different parts of the molecule; ask for both results and both detection limits.

Chain of custody matters. The sample tested should be the sample retained, and the report should name the lot. If a result is disputed, hand the referee the retained sample, the certificate and the specification, and ask for the separation tests rather than a repeat of the same assay.

What to compare between suppliers

Six lines make the comparison: the protein value with its factor, the IgG value with its method and standard, fat and lactose, moisture, the process temperature and the allergen and origin statements. Two quotations can agree on protein and disagree on IgG, fat and lactose, and then they describe two different powders.

Then check traceability: who collected the raw colostrum, how soon after calving, which drying step was used, and which lot code appears on the pouch, the drum and the retained sample. The catalog ranges are on the colostrum product page. The tests that separate colostrum from milk powder are on the identity page, the grade ranges on the grade page, the assay notes under methods, and the release workflow is set out on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation