What the COA for zinc bisglycinate actually contains
The certificate for a zinc bisglycinate lot reports appearance, zinc by complexometric EDTA, glycine by HPLC, the calculated Zn : glycine ratio, free glycine, pH, loss on drying, particle size, bulk density, the heavy-metal panel and microbiology. Every row should show the test, the method and the acceptance range used at release. The ranges on this page are the catalog specification; the batch COA is the document that confirms a particular drum. A zinc figure on its own will not prove the form.
A zinc number does not identify the molecule; the certificate has to show the ligand, the ratio and the solid form as well.
The certificate as a test report
A certificate is useful when it can be audited line by line. For each parameter the reader needs three things: what was measured, which method produced the number, and which limit the lot was released against.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White to off-white crystalline powder |
| Zinc (Zn) | Complexometric EDTA titration | 26.0–28.0% |
| Glycine | HPLC | 59.5–64.5% |
| Zn : glycine ratio | Calculated from the two assays | 1.95–2.05 mol glycine per mol Zn |
| Free glycine | HPLC | ≤1.0% |
| Loss on drying | Gravimetric | ≤8.0% |
| pH (1% suspension) | Potentiometry | 5.0–8.0 |
| Parameter | Method | Release limit |
|---|---|---|
| Particle size | Sieve analysis | ≥95% through 40 mesh |
| Bulk density | Tapped cylinder | 0.40–0.70 g/mL |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
What the zinc and glycine figures measure
Zinc is reported as elemental zinc, not as the chelate. Glycine is reported as glycine by HPLC. Neither figure is a purity percentage: a supplier may describe the powder as high-purity while the elemental zinc sits inside the 26.0–28.0% window, and the two statements answer different questions.
The ratio is arithmetic, not an analytical result. Convert the zinc result to moles using 65.38 g/mol, convert the glycine result to moles using 75.07 g/mol, and divide the glycine moles by the zinc moles. A true 1:2 chelate gives 2.00. The certificate's ratio is calculated from that lot's reported figures, not from the midpoint of the catalog ranges.
Two cautions belong beside that calculation. First, both assays must be on the same basis: a zinc figure reported as-is and a glycine figure reported on the dried or ligand basis cannot be divided into a meaningful ratio. The certificate should state the basis for each. Second, total glycine includes free glycine. A high total glycine with a high free-glycine result is added ligand, not more chelate; the ratio should be read together with the free-glycine figure. The 1.95–2.05 release window applies only after the two results are aligned.
The monohydrate carries water of crystallisation, so loss on drying checks that water and any moisture picked up in handling. The zinc result is reported on the material as sold; the hydrate state and the loss-on-drying figure belong beside the assay, not in a footnote.
Release limit versus batch result
The release limit is the acceptance boundary for the lot. What the laboratory measured on that lot is the batch result. Both belong on the page, in separate columns, with the method next to them. A result column filled with the specification range is not a result; it is a copy of the gate.
Not every line needs an acceptance range. Free glycine is the usual example: a result below the 1.0% limit can still vary from lot to lot. The figure matters because free glycine is ligand that did not react. A specification that caps total glycine without a free-glycine result can be satisfied by adding glycine at the blender.
The ratio is calculated, so its uncertainty is the uncertainty of both assays; it is an identity check, not a substitute for the two figures. “Passes specification” is also a conclusion, and the reader should be able to reach it from the numbers on the page.
What moves between batches
Zinc and glycine move with the reaction and crystallisation; the ligand assay reads the same reaction from the other side, so a true chelate keeps the ratio near 2.00. Drying controls loss on drying, residual liquor controls pH, and milling and sieving control particle size and density.
Colour and flow are less quantitative and often more revealing. A cream or tan tint can point to a hot drying step, a trace of iron or a Maillard reaction with a reducing sugar while the zinc assay still passes; request the batch record rather than rejecting the lot on colour alone.
A trend across lots — zinc drifting low, free glycine climbing — says more than one result near an edge.
When to order an outside test
Order an independent test for a new source, a first shipment into a regulated market, a form claim the supplier's certificate does not prove, or a disputed result. The useful panel is not a full repeat: X-ray diffraction for crystalline zinc oxide, FTIR for glycine coordination, and ICP-MS for the heavy-metal panel, all on one submitted sample.
Ask the laboratory to report its detection limit for the XRD oxide screen. A “not detected” line without a limit is not evidence about the sample; it is evidence about the method's sensitivity. The same principle applies to the glycine assay: the report should name the column, the detector and the basis, not only the percentage.
An outside laboratory is also the sensible referee when a result is contested. Give the referee the retained sample, the supplier's certificate and the specification, and ask for the tests that separate the forms. Chain of custody matters: the sample tested should be the sample retained.
What to compare between suppliers
Put six lines side by side: form and hydrate state; zinc result and method; glycine result and basis; calculated ratio; free glycine; XRD oxide screen. Two quotations that match on zinc but diverge on the other five are not describing the same powder.
The second layer is lot traceability. The lot code should be identical on the certificate, the drum and the retained sample. The certificate should also say who manufactured the lot, which zinc source was used and which drying step was applied; a correct certificate can still belong to a drum other than the one on the loading dock.
The catalog specification sits on the zinc bisglycinate product page. Grades are compared on the grade page; the tests that separate chelate from blend are on the identity page; the release workflow is on the quality page. The titration itself is described in the complexometric method note.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation