01 COA & batch testing

What the COA for selenium glycinate actually contains

Technical document 01 · Reviewed 2026-11-20 · Selenium Glycinate

On this page
  1. What the certificate reports
  2. Selenium basis, glycine basis and the ratio
  3. The gate and the measured value
  4. Batch-to-batch variation
  5. Independent testing
  6. Choosing between suppliers

Selenium glycinate is released on total selenium by ICP-MS, glycine by HPLC with the chelate ratio, appearance, loss on drying, heavy metals, microbiology and particle size. The catalog sets selenium at 1.0–2.0%, a conforming glycine ratio, loss on drying ≤5.0% and ≥95% through 80 mesh. A useful certificate pairs every parameter with the method that produced it, the limit it was released against and the result for that pack.

In one line

The selenium figure shows how much of the element is in the lot; the glycine ratio and the speciation show whether it is a chelate, and a certificate needs all three.

What the certificate reports

A certificate is only as good as its weakest line. Each entry should identify the test, the method behind the number and the limit that applied, so a reviewer can follow the reasoning without calling the supplier. A row that reads “conforms” gives a verdict and withholds the basis for it.

The selenium line measures the element. The glycine line measures the ligand, and even a good glycine figure is a count rather than a species test. The identification line refers to whatever reference method the specification names; it does not, by itself, show that this lot matches it.

Identity, selenium, ligand and contaminants · selenium glycinate
ParameterMethodRelease limit
AppearanceVisualWhite to off-white powder
IdentificationSelenium and glycine against the referenceConforms
SeleniumICP-MS1.0–2.0%
Glycine (chelate ratio)HPLCConforms to the agreed ratio
Loss on dryingGravimetric≤5.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

Two rows often carry less than they promise: “identification: conforms” without the reference, and “glycine: conforms” without the number behind the ratio.

Selenium basis, glycine basis and the ratio

The selenium result can be reported as received or after drying, and the certificate must say which. A 1.5% figure with 3.0% loss on drying becomes 1.546% on the dried basis. That is only 0.046 points, but it is 3% of the value, and the glycine ratio moves with it. Mixing an as-is selenium figure with a dried-basis glycine figure produces a number that means nothing.

Before the ratio can be checked, three things must be fixed: the selenium basis, the glycine basis, and whether the glycine is total or free. Total glycine covers the ligand plus anything the carrier contributes; free glycine is the uncomplexed part. The ratio is a molar calculation on the bound fraction, so total glycine alone does not supply it. On the selenium side, the digestion and the isotope belong in the method note; neither tells you whether the element is chelated.

The gate and the measured value

Each specification line has a limit set in advance and a result measured afterwards. They answer different questions, and they belong in separate columns. A result column that simply repeats the catalog range has said nothing about the lot.

What the result column should contain
ParameterRelease limitResult column
Selenium1.0–2.0%A measured percentage, with the basis and the digestion stated
Glycine ratioConformsThe measured glycine figure and the calculated molar ratio
Loss on drying≤5.0%A measured percentage
Heavy metalsPer elementA measured figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot
Particle size≥95% through 80 meshThe measured percentage through the sieve

The conclusion “passes specification” should be visible in the numbers: one figure per metal, a count plus an absence statement for microbiology, a measured percentage through the sieve. A single “heavy metals: conforms” entry conceals which element was high.

Batch-to-batch variation

The selenium window is deliberately broad. 1.0–2.0% is a two-fold range, so two compliant lots can differ by 100% in selenium per gram. That follows from a chelate whose load depends on the reaction and the carrier rather than on one formula. The weigh-up must use the lot value; a formula built on the midpoint is exposed at both ends.

Moisture follows the pack and the season. A drum opened in a humid room takes up water, the as-is selenium figure falls, and the powder starts to cake. Sieving and milling shift the particle-size line while the chemistry stays put. Colour is the least quantitative row: white to off-white is a wide window, and a pink or grey cast points to a different problem rather than a slightly different shade.

Look at the direction of travel across lots rather than one value near a limit: selenium falling, moisture rising, or a new peak in the glycine run. The lot code should follow the material into the pouch, the drum and the retained portion.

Independent testing

An outside laboratory is worth engaging at four moments: a new source, a first shipment into a regulated market, a label that depends on the chelate, or a contested result. The panel should cover total selenium by ICP-MS, speciation by IC-ICP-MS or HPLC-ICP-MS for selenite and selenate, glycine with the free fraction, loss on drying, metals and microbiology.

Speciation is the gap in a routine certificate. Total selenium cannot separate a chelate from a physical blend of sodium selenite and glycine, and a blend is a direct way to hit the same figure. Ask for the extraction, the species calibrated and the limit of quantification; “selenite not detected” without a limit describes the method, not the lot.

Keep the chain of custody intact: test the portion that was retained, and make sure the report names the lot. If a result is disputed, send the referee the retained portion, the certificate and the specification, and ask for the tests that separate bound from inorganic selenium rather than another total-selenium figure.

Choosing between suppliers

Six lines are enough to compare two offers: the selenium value and its basis; glycine total, free and the calculated ratio; whether speciation was run; the carrier and how it is declared; loss on drying; and the pack with its lot code. If two offers match on selenium but not on carrier or speciation, they are not the same material.

Traceability is the second layer: who made the lot, which selenium source and ligand were used, and what carrier and drying step followed. The catalog specification is published on the selenium glycinate page; the speciation tests are explained on the identity page; the carrier and presentation choices on the grade page; the ICP-MS method in the ICP-MS note; and the release route on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation