What the COA for potassium iodide actually contains
A potassium iodide certificate reports the assay by titration at 99.0–101.5%, the iodide content at 75.0–78.0%, loss on drying at ≤1.0%, identification by IR and titration, the heavy-metal panel and microbiology. The assay and the iodide figure describe the same salt and should agree through the 76.45% theoretical iodine fraction. The sheet should also show the reducing-agent limit named in the catalog note, because iodide that has oxidised is no longer the material the buyer ordered.
The assay, the iodide figure and the loss on drying belong on one certificate: together they show whether the lot is potassium iodide or a diluted or oxidised version of it.
The certificate as a test report
A certificate is a test report, not a statement of conformity. Each line should name the parameter, the method and the release limit, and the measured result should sit in its own column. A row that says “conforms” without the figure behind it asks the reader to trust a conclusion.
The identity row decides whether the material is potassium iodide. The assay and iodide rows decide how much of it is there. The water row decides how much of the weighed powder is not the salt.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White crystals or powder |
| Identification | IR and titration | Conforms to the reference |
| Assay | Titration | 99.0–101.5%; state the basis |
| Iodide (iodine) | Titration | 75.0–78.0% |
| Loss on drying | Gravimetric | ≤1.0% |
| Heavy metals | ICP-MS, each element | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Aerobic count and yeast/mould | Plate count | Not more than 1,000 cfu/g; not more than 100 cfu/g |
| E. coli and Salmonella | Absence tests | Absent |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
Assay basis, the iodide figure and the water
The assay is normally reported on the dried basis, but the certificate has to say so. The two quantitative lines are linked by the formula: KI contains 126.90 g of iodine per 166.00 g of salt, or 76.45% iodine by mass. A lot that measures 100.0% assay on the dried basis therefore carries 76.45% iodide, a lot at 99.0% carries 75.69%, and a lot at 101.5% carries 77.60%. All three sit inside the 75.0–78.0% iodide window, which is why the two ranges are bought together.
If the assay is reported on the as-is basis instead, the loss on drying is the bridge. A certificate that reads 99.0% as-is at 0.8% loss on drying is 99.8% on the dried basis; the iodide figure should be read against the same basis. The common mistake is to compare an as-is assay with a dried-basis iodide value and conclude that the lot is out of specification when the numbers are simply on different footings.
Identification by IR and titration is a separate question. The IR spectrum should be compared with a reference, and the titration values should agree with the declared salt. Ask for the spectrum and the titration method, not only the word “conforms”.
Release limit versus batch result
The release limit is the boundary; the batch result is what the laboratory measured. Both belong on the page, in separate columns, with the method beside them. A result column filled with the specification range is a copy of the gate, not evidence that the lot passed it.
| Parameter | Release limit | Result column |
|---|---|---|
| Assay | 99.0–101.5% | A measured percentage, with the basis and method |
| Iodide | 75.0–78.0% | A measured percentage on the same basis |
| Loss on drying | ≤1.0% | A measured percentage |
| Free iodine and reducing agents | Limit set in the specification | The measured figure and the method |
| Heavy metals | Per element | A measured figure in mg/kg for each element |
“Passes specification” is a conclusion; the reader should be able to reach it from the numbers. A heavy-metal total hides the element that matters, and a microbiology line without the count hides the magnitude.
What moves between batches
Crystallisation and drying move the assay and the water. Milling and sieving move the particle-size result, so the 40 mesh line can change when the mill or the sieve changes without any change in the chemistry. Exposure to air and light moves the colour: free iodine is yellow to brown, and a white lot that starts to look cream is telling the reader something.
Colour is not a quantitative test. A pale yellow tint can come from a small amount of free iodine, from a different drying step or from a packaging leak; the free-iodine or reducing-agent line is what separates those cases. Rejecting on colour alone can discard a lot that still meets the assay and iodide limits, and accepting on colour alone can miss oxidation that has not yet moved the assay.
Watch the direction of travel rather than a single result near a limit: water rising, iodide falling, or a yellow tone appearing in the retained sample. The lot code should link the certificate, the pouch, the drum and the retained sample.
When to order an outside test
An outside test earns its place when the source is new, the destination is a regulated market, the identity is disputed or the powder has changed colour. Do not simply repeat the certificate: specify IR, titration for assay and iodide, loss on drying, ICP-MS metals, microbiology, and a dedicated free-iodine or iodate test. Add chloride and bromide by ion chromatography if a white diluent is the concern.
The report should give a detection limit for every screen. A “not detected” line without one describes the method, not the sample. If a result is contested, send the referee the retained sample, the supplier's certificate and the specification, and ask for discriminating tests rather than a second run of the same assay.
What to compare between suppliers
Compare suppliers on six lines: identity and CAS; assay with its basis; iodide; water; free iodine or reducing agents; metals, microbiology and pack. If two offers agree on assay but not on the iodide basis or the water, they describe different powders.
The potassium iodide product page carries the catalog specification. The identity page shows how the iodide figure is used as a check, the compliance page covers the destination file, the methods notes describe the titration and IR work, and the quality page describes the release workflow.
Related documents