06 Identity & adulteration

How we prove a phytosterol lot is the named mixture

Technical document 06 · Reviewed 2026-11-19 · Phytosterols

On this page
  1. Five pieces of evidence
  2. The ratios and the source
  3. X-ray diffraction: what it can and cannot do
  4. Adulteration and its signals
  5. Writing identity into the specification
  6. Questions that produce an identity file

A phytosterol lot is not identified by one beta-sitosterol number. The evidence is a GC profile: total sterols, the sitosterol, campesterol and stigmasterol percentages, the minor sterols and the ratios between them. The profile has to fit the declared source and close with the moisture figure.

In one line

Identity is the profile: the total sterol figure, the three marker sterols and the source markers have to agree before the lot is the material named on the label.

Five pieces of evidence

Identity is a set of measurements that agree, not a single test that passes. The useful evidence is the document, the GC peak table, the total sterol mass balance, the minor-sterol pattern and, where the solid form is in question, an X-ray diffraction pattern. Each answers a different question; none of them alone proves the material.

Evidence for a phytosterol identity file
EvidenceQuestion it answersWhat it cannot show
DocumentIs the material, form and source named?Whether the powder matches the paper
GC peak tableWhich sterols are present, and in what proportion?Whether the solid form is crystalline
Total sterol mass balanceDo the total, the individual figures and the moisture agree?Which source the sterols came from
Minor-sterol patternDoes the source declaration fit the fingerprint?A quantitative total sterol result
XRD patternIs the solid crystalline, and does it match a reference?The sterol ratio or the total content

The ratios and the source

The catalog ranges are beta-sitosterol 40.0–60.0%, campesterol 20.0–30.0% and stigmasterol 15.0–25.0%, with total sterols ≥95.0%. A lot must sit inside each range, but the ranges alone do not identify the source. The ratios do more work: a sitosterol to campesterol ratio near 2 and a stigmasterol level above 15% fit a soy-type mixture; a tall-oil material is mostly sitosterol with little stigmasterol; a sunflower material usually carries less stigmasterol and a delta-7-stigmastenol marker.

The minor peaks are the fingerprint. Brassicasterol points to rapeseed, delta-7-stigmastenol to sunflower, avenasterol to several seed oils. A peak table that stops at the three named sterols leaves the source question open, which matters when the allergen or GMO statement depends on it.

Normalisation is the other trap. A result can be a percentage of the total sterol fraction or a percentage of the powder as weighed. The two are different, and the certificate should state which. The individual figures and the total should also close with the loss on drying; if they do not, the mass balance is the first thing to investigate.

X-ray diffraction: what it can and cannot do

Free phytosterols are crystalline, so an XRD pattern can show whether the solid is crystalline and whether it matches a sterol reference. That is useful when a dilution with an amorphous carrier is suspected, or when two lots from different sources are being compared.

XRD cannot quantify the sterol profile. It will not tell the buyer how much sitosterol, campesterol or stigmasterol is present, and it cannot replace the GC. A “match” statement without the reference pattern and the detection limit is not evidence. For a disputed lot, use XRD with the GC and the mass balance, not instead of them.

Adulteration and its signals

Phytosterol substitutions and the evidence that catches them
SubstitutionWhat changesEvidence
Silica, starch or maltodextrinLess sterol per gramTotal sterols low; ash, loss on drying or mass balance shifts
Tall-oil sterolsMostly sitosterol; little campesterol or stigmasterolStigmasterol below range; high sitosterol to campesterol ratio
Added stigmasterolRaises the total sterol figureStigmasterol above range; the other sterols fall
Sterol ester in a free sterol lotFatty acid mass; different solubilityFree sterol low; ester value present
WaterLower as-is sterol figureLoss on drying high; dried-basis total normal

Appearance is the weakest evidence: a white diluent looks like a white sterol. The profile, the ratios and the mass balance are stronger. A supplier who reports only appearance and total sterols has left a common substitution untested.

Writing identity into the specification

  • “Phytosterols, free sterol powder, source declared; CAS 83-46-5 for the beta-sitosterol reference.”
  • “Total sterols ≥95.0% by GC; beta-sitosterol 40.0–60.0%, campesterol 20.0–30.0%, stigmasterol 15.0–25.0%.”
  • “Identification by GC retention time against a sterol standard mixture; report the full peak table.”
  • “Loss on drying ≤2.0%; the certificate states whether the sterol result is as-is or dried basis.”
  • “Report the minor sterols, including brassicasterol and avenasterol, where the source claim depends on them.”
  • “Particle size ≥95% through 80 mesh; heavy metals and microbiology as listed.”

Questions that produce an identity file

  1. Which source is this lot, and does the minor-sterol pattern support the declaration?
  2. Can you send the full GC peak table and the chromatogram, not only the three named percentages?
  3. What is the total sterol basis, and how do the individual figures close the mass balance?
  4. Is the material the free sterol or an ester, and which test shows the form?
  5. If a result is contested, would you agree to a joint re-test of the retained pack?

The five answers together are the identity file; one assay percentage is not. Specification: product hub. Certificate lines: COA page. Forms: grade page. Free sterol versus ester: level-four page. GC background: methods index.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation