What a phytosterol COA contains, line by line
A phytosterol certificate is read in two passes. The profile pass gives total sterols by GC and the individual sitosterol, campesterol and stigmasterol figures; the contaminant pass gives moisture, heavy metals, microbiology and the 80 mesh finish. A lot is released only when both passes are complete and the basis of the sterol figure is stated.
The total sterol figure says how much sterol is present; the sitosterol, campesterol and stigmasterol profile says which sterols, and a certificate needs both before the lot can be released.
Reading the certificate line by line
A certificate earns its place when a customer can audit it without calling the supplier. Every line should name the parameter, the analytical method and the acceptance limit; the measured value belongs in its own column. “Conforms” is a conclusion; the reader needs the evidence that produced it.
The specification is split into two blocks. The first is identity and profile; the second is moisture, contaminants and physical finish. The limits below are catalog limits, not the results of a particular lot.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White to off-white powder |
| Identification | GC sterol profile against standards | Conforms to the reference profile |
| Total sterols | GC, sum of identified sterols | ≥95.0% |
| Beta-sitosterol | GC | 40.0–60.0% |
| Campesterol | GC | 20.0–30.0% |
| Stigmasterol | GC | 15.0–25.0% |
| Parameter | Method | Release limit |
|---|---|---|
| Loss on drying | Gravimetric | ≤2.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
The GC basis: total sterols after saponification
The number depends on the work-up. The usual method hydrolyses the sample with alkali, extracts the unsaponifiable matter, silylates the sterols and separates them by capillary GC with flame-ionisation detection. Retention times are matched to a standard mixture, and the total is the sum of the identified peaks.
Because the hydrolysis step cleaves sterol esters, the result is total sterols rather than free sterols. That is the right figure for the free sterol powder, where the two are close. It is not enough to describe an ester: the same method measures the sterol cargo, and a separate free-sterol or ester-value test is needed to show the form. The certificate should name the work-up, not only the instrument.
Moisture is the second basis. With loss on drying at ≤2.0%, a dried-basis total and an as-is total can differ by about two percentage points. A lot at 95.8% as-is with 1.7% moisture is 97.46% on the dried basis; the same 95.8% on the dried basis is 94.17% as-is. The certificate should say which one it reports, beside the result.
Release limit versus batch result
A limit is a boundary; a result is a measurement. They belong in different columns, with the method named. A result column that repeats the specification range has not reported a measurement.
| Parameter | Release limit | Result |
|---|---|---|
| Total sterols | ≥95.0% | A measured percentage, with the basis and method |
| Individual sterols | Three ranges | A measured figure for each named sterol and the minor peaks |
| Loss on drying | ≤2.0% | A measured percentage |
| Heavy metals | Per element | A measured figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
The profile is a set, not four separate pass or fail lines. The total must be consistent with the individual sterols, the minor peaks must be reported, and the moisture must explain the gap between the as-is and dried figures. A certificate with a total of 96% and individual figures that sum to 89% has a mass-balance question, even if every line is inside its range.
The three ranges are broad because the raw material is a plant mixture. They are markers, not the whole composition. Brassicasterol, avenasterol and other minor sterols are part of the identity evidence and should appear in the peak table.
What moves between batches
Source and season move the profile more than the process does. A soy-type mixture, a sunflower-derived one and a tall-oil material have different sitosterol, campesterol and stigmasterol balances. A source change can therefore pass the total sterol limit and still fail the profile that the customer bought.
Refining and crystallisation affect colour and the minor-sterol fraction; drying affects moisture; milling and sieving affect the 80 mesh result without touching the chemistry. The last point matters commercially: a new mill can change the particle-size line while the certificate's chemistry stays identical.
Watch the direction of travel across lots, not just the latest number. A slow fall in total sterols, a stigmasterol result that has moved to the edge of its range, or a rising loss on drying is more informative than a single result in the middle. The certificate’s lot code should be the same code that appears on the pouch, the drum label and the sample kept for reference.
When to order an outside test
An outside laboratory is worth using when the source is new, the destination is regulated, the profile does not fit the declared source, or a result is disputed. The panel should be chosen for the question: GC with the chromatogram and peak table for identity, loss on drying for the moisture basis, ICP-MS for the metals, and a plate count plus absence tests for microbiology.
If the material has been stored warm or is going into an oil blend, add the sterol oxidation products: 7α-hydroxy, 7β-hydroxy and 7-ketositosterol are the usual markers. If the extraction route is unclear, add residual solvents; if the market asks, add mineral oil hydrocarbons. A “not detected” statement needs a detection limit beside it, otherwise it describes the method rather than the sample.
Keep the chain of custody short. The pack that was tested should be the pack that was retained, and the report should carry the lot code. In a dispute, give the referee the sample kept for reference, the supplier's certificate and the agreed specification, and ask for the test that tells the two possible sources or forms apart.
What to compare between suppliers
Compare seven things: form and source; total sterols and the basis; the three marker sterols and the minor peaks; loss on drying; heavy metals and microbiology; particle size; pack and lot code. Two offers that match on total sterols but differ on source or form are not the same material.
Then check the paper trail: who made the lot, which raw material and process route were used, and how the material was dried and milled. The catalog specification is on the phytosterol hub; the profile tests are on the identity page; the form choice is on the grade page; the market file is on the compliance page; the GC background is in the methods index; the release route is on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation