01 COA & batch testing

What the COA for nervonic acid actually contains

Technical document 01 · Reviewed 2026-11-19 · Nervonic Acid

On this page
  1. The certificate as a test report
  2. Which basis the percentage stands on
  3. The limit and the result are different columns
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

A nervonic acid certificate reports appearance, identity by GC, the C24:1 assay, the neighbouring acids, acid value, moisture, the metals, microbiological counts and mesh size. The batch result has its own column beside the limit, and the assay has to say which basis it was measured on. The numbers in the first table are the catalog gate; the certificate is what a particular pack was released against.

In one line

A C24:1 percentage is only the identity when the certificate shows the chain length, the free-acid content and the basis behind the number.

The certificate as a test report

An audit reads a certificate one line at a time. Each line should say what was measured, how, and the limit the lot had to meet. A line that says “conforms” and nothing else asks the reader to take the conclusion on trust, which is the opposite of what the document is for.

Lines, methods and gates · nervonic acid
LineMethodCatalog gate
AppearanceVisualWhite to off-white waxy powder
IdentificationGC retention against a C24:1 standardMatches the reference
Assay, C24:1GC-FID of methyl esters≥90.0%
Acid valueTitration, mg KOH/gReported
MoistureLoss on drying, gravimetric≤1.0%
MetalsICP-MS after digestionPb ≤3 · Cd ≤1 · As ≤2 · Hg ≤0.1 mg/kg
MicrobiologyPlate count, with absence enrichmentAPC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · absence confirmed for E. coli and Salmonella
MeshSieve, 80 mesh≥95% through

Two of those lines carry the identity. The chromatogram shows that the main peak is C24:1; the assay says how much of the material that peak represents. A lot can satisfy the first and miss the second, and a certificate that prints only a percentage has settled neither point.

Which basis the percentage stands on

“90%” can mean three different numbers, and the certificate should say which one it means. The first is calibration: normalising peak areas to the identified total is common, and it says nothing about material that never left the column. An internal standard, by contrast, turns peak area into mass.

The second is the molecule on the balance. Methyl esters are what the instrument sees, and the ester of nervonic acid weighs 380.66 g/mol where the acid weighs 366.63. Reporting 90.0% as the ester is therefore about 86.7% as the acid once the 0.963 factor is applied. Whichever number the certificate uses, the specification and the label must use the same one.

The third is water. With moisture capped at ≤1.0% the correction is small, but the assay line should still say whether it is as received or dried. A chromatogram with the integration and the standard settles all three; a bare percentage settles none.

The limit and the result are different columns

Every line needs two numbers: the limit the lot was released against, and the figure the laboratory found. They are not interchangeable, and a result column that repeats the range has told the reader nothing about the drum.

What the result side of the certificate should show
LineWhat to look forWhy it matters
AssayA result, a basis and an ester factorA percentage without a basis cannot be compared
Neighbouring acidsC24:0 and C22:1 from the same injectionShows how hard the cut was run
Acid valuemg KOH/g and the titration methodSeparates a free acid from an ester
MoistureA measured figureCloses the mass balance
MetalsOne figure per elementA sum hides the element that failed
MicrobiologyA count plus the absence wordingTwo different questions on one line
MeshMeasured percentage through the sieveDescribes the mill, not the molecule

The acid value earns its place on a free-acid product, and it is the simplest cross-check on the page. Pure nervonic acid calculates to about 153 mg KOH/g; a 90% acid whose balance is neutral lipid lands nearer 138, while one whose balance is other free acids stays close to 153. That one titration separates a diluted acid from a mixed acid.

What moves between batches

At 90%, nervonic acid is a fractionated material. The enrichment, usually a crystallisation from a seed oil with a urea adduction step, sets how much C24:0 and C22:1 remain beside the C24:1. A low assay lot carries more saturated C24:0, and the melting range betrays it: the catalog range is 42–44 °C, and a wider, higher or lower range points to a different distribution.

Colour, moisture and mesh track the drying and milling steps, not the chemistry. The 80 mesh line describes the mill, so a new sieve can move it while the assay sits still. A finer powder also offers more surface to oxygen, and a lot milled harder can oxidise sooner at an unchanged assay.

Look at the trend across lots rather than at one result near an edge: assay sliding down, acid value sliding up, or an extra peak beside C24:1. Pouch, drum and retained sample should all show the code printed on the certificate.

When to order an outside test

An outside laboratory earns its place in four situations: a source you have not used, a first entry into a regulated market, a chain-length claim the supplier's paperwork does not support, and any result you doubt. A useful panel is GC-FID on a long polar column for identity and assay, GC-MS to confirm the C24:1 peak, titration for acid value, moisture, peroxide and anisidine values, ICP-MS for the metals and a microbiology set.

Ask for cis and trans to be reported on separate lines. The trans isomer has the same chain length and a subtly different retention, and not every routine column resolves the pair, so the report should state whether the separation was attempted. A “not detected” entry with no detection limit is a statement about the method rather than the sample.

Keep the chain of custody intact. The referee should be able to match the jar on the bench to the code on the report. If a result is disputed, hand over that jar, the specification and the certificate, and ask for a separation rather than another run of the same percentage.

What to compare between suppliers

Six lines make a fair comparison: identity, meaning the peak and the column that resolved it; assay and its basis; the C24:0 and C22:1 figures; acid value; moisture and metals; and the pack with its code. Two quotations that agree on 90% but disagree on the ester factor or the acid value are not selling the same material.

The next layer is provenance: which seed oil the lot came from, which site ran the enrichment, and which mill set the mesh. A macadamia-derived lot and an Acer truncatum-derived lot are the same molecule with different source records, and that record is what the allergen and origin statements rest on.

The catalog gate is published on the nervonic acid product page. The chain-length tests are set out on the identity page; the form options are on the grades page; the chromatographic background is in the analytical methods index; the release routine is set out on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation