What the COA for algal DHA powder actually contains
An algal DHA certificate reports three things about one lot: DHA by gas chromatography, the oxidation state of the oil, and what the rest of the powder is. The catalog specification is DHA (GC) ≥10.0%, moisture ≤5.0%, peroxide value ≤5.0 meq/kg, p-anisidine value ≤20.0 and a declared modified-starch carrier. The certificate records that a lot met those limits; the specification is only the gate.
A DHA certificate has to carry the GC figure and the oxidation figures side by side, because 10% DHA and a low peroxide value are separate facts about the same lot.
What the certificate has to carry
Read a certificate as a series of statements about one lot, each with a method and a limit attached. A line with a method but no limit says nothing about the release decision.
| Parameter | Method | Release limit |
|---|---|---|
| DHA (identity and assay) | GC-FID of methyl esters; peak identified against a DHA standard | Peak at the expected retention time; ≥10.0% |
| EPA | GC-FID, same run | Reported |
| Moisture | Gravimetric, vacuum oven | ≤5.0% |
| Peroxide value | Titrimetric; AOCS Cd 8b-90 or ISO 3960 | ≤5.0 meq/kg |
| p-Anisidine value | Spectrophotometric; AOCS Cd 18-90 or ISO 6885 | ≤20.0 |
| Carrier | Declaration with mass balance | Modified starch, declared |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count, absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
Appearance belongs on the same sheet: off-white to light yellow, free-flowing. Colour is not a release limit in the way the assay is, but a brown cast is a reason to read the oxidation lines first. The lot code, the manufacture date and the expiry date belong there too: an analysis with no lot attached cannot be traced to a drum.
What the 10% figure measures
The 10.0% figure is grams of DHA per 100 g of powder, set by the oil's DHA content and the oil load in the encapsulation. An oil in the 35–45% DHA range needs a load of roughly 22–29% to reach 10%, and analysed alone it would report 35–45%. The certificate therefore has two denominators, powder and extracted oil, and should say which one the result uses.
Calibration matters as much as the denominator. A GC run on methyl esters can be quantified against an internal standard, giving grams per 100 g, or normalised to peak area, giving a composition of the extracted oil. Area percent is a valid profile; it is not a content claim on the powder. Check whether the result is as sold or on a dried basis — at moisture ≤5.0% the gap is small, not zero.
DHA is one fatty acid, not a synonym for omega-3. Algal oil is DHA-dominant with a small EPA fraction and a measurable DPA fraction, so a certificate reporting only total omega-3 does not state the DHA content a label must declare.
Release limit versus batch result
A limit is the boundary for release; a result is what the laboratory found. Keep them in separate columns, with the method named. If the result column repeats the range, the gate has been copied and no measurement is recorded. “Passes specification” should be checkable, not a substitute for the numbers.
Peroxide value and p-anisidine value describe two stages of one process. Peroxide value titrates hydroperoxides, the first products of lipid oxidation, and can fall again as they decompose. p-Anisidine value measures the aldehydes that follow, so it rises later and stays. A lot at peroxide value 1.0 with p-anisidine 18 is further into oxidation than one at peroxide value 4.0 with p-anisidine 3, though both pass. Read the pair, not the first number.
The two limits combine as TOTOX, twice the peroxide value plus the p-anisidine value. At the catalog ceilings, 5.0 meq/kg and 20.0, TOTOX is 30; a ceiling combination is a pass, not a target.
Moisture is a limit because water plasticises the starch wall and gives oxygen a faster route to the oil. Carrier is a declaration line because modified starch is the wall itself, not an impurity, and must be consistent with the DHA figure and oil load. If DHA is 10.0% and the oil load is absent, the sheet is incomplete.
What moves between batches
DHA moves with the fermentation lot, the oil refining and the encapsulation; a change of oil supplier, deodorisation step or dryer setting can shift it. A lot at 9.9% is a process drift to investigate, not proof of a bad material. Peroxide and p-anisidine values move with heat, oxygen, light and time, and a lot that left clean can arrive higher if the pouch is not a barrier. Moisture moves with drying and humidity at packing, particle size with the mill and sieve, and colour and odour with oxidation before any number moves.
Retained samples turn those movements into a trend: compared with a limit a result says pass or fail, compared with the previous five lots it says which way the process is going. The stability page follows those trends through storage.
When an outside laboratory earns its fee
An outside laboratory is worth commissioning on a new source, a first delivery into a regulated market, a contested result, or a buyer that tests every incoming lot. The useful panel answers what the certificate leaves open: GC-FID with a DHA standard and the full fatty-acid profile, peroxide and p-anisidine values by a named method, sterols where the algal source is in doubt, ICP-MS for the metals, and a plate count with absence tests.
Two details decide what the report is worth. A “not detected” line needs a limit of quantification, otherwise it describes the method, not the sample. And on a microencapsulated powder the oxidation figures are measured on oil recovered from the matrix; recovery can add or remove peroxides, so ask how the oil was recovered and whether the figures refer to that oil or back to the powder.
What to compare between suppliers
Compare six lines, not one. Quotations that match on DHA and diverge on the rest describe different powders under the same name.
| Line | What to request | What it exposes |
|---|---|---|
| Source | Algal oil supplier, strain and origin | Same assay, different source file |
| DHA result | Lot result, GC setup and standard | A lot result, not a copied range |
| Profile | EPA and DPA alongside DHA | A concentrate from a different oil spectrum |
| Oxidation | PV and p-AV, methods and oil recovery | A fresh oil from an aged one |
| Carrier | Modified starch identity and oil load | A declared wall from an undeclared dilution |
| Traceability | Lot code on COA, pack and retained sample | A certificate from another drum |
The catalog specification sits on the algal DHA powder product page. The tests that separate algal oil from fish oil are on the identity page, certificate terms are in the COA glossary entry, and the way evidence is retained is described on the quality page.