06 Identity & adulteration

How to prove a powder is serratiopeptidase

Technical document 06 · Reviewed 2026-11-19 · Serratiopeptidase

On this page
  1. The identity layers
  2. The activity-to-protein ratio
  3. X-ray diffraction: what it can and cannot show
  4. Substitutions and their signals
  5. Identity clauses for the specification
  6. Five questions before qualification

A serratiopeptidase lot is identified when several independent lines agree: the document names the preparation, the casein assay shows activity, the protein pattern shows a band at the expected molecular mass, and the specific activity is consistent with the declared units. The activity assay alone shows that the powder hydrolyses casein; it does not show which protease is doing it.

In one line

The activity assay shows that something in the powder cuts casein; identity needs the name, the protein band and a specific activity that agree.

The identity layers

A certificate can carry the right name and still fail to prove the material. The layers below ask separate questions, and each needs its own evidence. A supplier who answers only the first has described the paperwork, not the powder.

Layers of serratiopeptidase identity
LayerQuestionTestWhat it proves
DocumentIs the article named?Name, CAS 37312-62-2, EC 3.4.24.40, source strainPaperwork only
ActivityIs it a casein protease?Casein Folin assay, unit definition statedProteolytic activity, not identity
ProteinWhich proteins are present?SDS-PAGE against a molecular-mass markerThe band pattern, including extra proteins
Specific activityIs the activity diluted or substituted?Units per gram divided by protein per gramConsistency between activity and protein
StructureDoes the solid match the reference?IR spectrum; XRD for the solid stateSimilarity to a reference, and the carrier

The molecular mass reported for serratiopeptidase varies with the method and the preparation, broadly in the 45–51 kDa range. A single strong band near that region, with the activity and the specific activity beside it, is stronger evidence than a certificate that says “conforms”.

The activity-to-protein ratio

The ratio of units to protein is the quickest check on a dilution. If an inert carrier is added, both the activity per gram and the protein per gram fall, and the ratio stays roughly the same. If the activity is unchanged while the protein content changes, the material is not simply diluted; either the enzyme amount or the enzyme itself has changed. The ratio therefore reads as consistency, not as a purity figure.

An example makes the arithmetic clear. A powder at 20,000 U/g with 20% protein carries 100,000 U per gram of protein. A second powder at 20,000 U/g with 10% protein carries 200,000 U per gram of protein; the same units now sit on half the protein, which points to a different preparation, a different standardisation or a more active enzyme. Neither figure is a specification by itself, and the method used for protein matters: Kjeldahl measures nitrogen, while a dye-binding method measures protein differently. State the method when the ratio is quoted.

The ratio is not a routine catalog line. Ask for it when a new source is qualified, when a dilution is suspected, or when two quotations differ without a visible change in the specification. The COA page shows where activity and protein belong on the certificate.

X-ray diffraction: what it can and cannot show

An enzyme powder is largely amorphous, so its X-ray diffraction pattern is a broad halo rather than a set of sharp crystalline peaks. Sharp peaks in the pattern come from something else: a crystalline carrier, a salt, or a mineral added to the blend. XRD is therefore a solid-state and carrier test, not an identity test for the enzyme.

That does not make it useless. XRD can show whether a lot contains a crystalline filler that the specification did not declare, and it can compare the carrier between two lots. It cannot confirm that the protein is serratiopeptidase, and it does not measure the activity. A certificate that reports “XRD conforms” without the pattern, the reference and the phases identified has added very little.

For a disputed lot, IR plus SDS-PAGE plus the activity result is the useful combination. The methods page describes the assay side of that file. XRD belongs in the file only when a solid-state or carrier question is actually open.

Substitutions and their signals

The activity figure is the easiest number to satisfy and the easiest to fake. A powder can reach 20,000 U/g by carrying a different protease, and the certificate will look normal unless the protein pattern and the specific activity are examined.

Common serratiopeptidase substitutions and the signals
AdulterantWhat it doesSignalTest
Inert carrierLowers units per gram; adds massActivity low; protein low; ratio steadyActivity, protein, IR
Other protease blendRestores activity with another enzymeExtra protein bands; different specificitySDS-PAGE, specific activity, substrate panel
Different enzymeSubstitutes a protease of another classWrong molecular mass; inhibition pattern differsSDS-PAGE, inhibitor study
Denatured powderProtein present, activity lostBand present; activity low; ratio lowActivity, specific activity
Water or humectantRaises mass; activity per gram fallsLoss on drying high; ratio dilutedLoss on drying, activity

Bromelain, papain and alkaline protease are all proteases that hydrolyse casein, so the Folin assay will count them. A blend can pass an activity specification and still be a different product with a different unit definition, a different stability profile and a different regulatory description. That is why the specification should say “single enzyme preparation”, and why a blend should be declared as a blend.

Identity clauses for the specification

  • “Serratiopeptidase, CAS 37312-62-2, EC 3.4.24.40, from Serratia marcescens, strain stated.”
  • “Activity ≥20,000 U/g by the casein Folin assay, with the pH, temperature, incubation time and unit definition stated.”
  • “Identification by IR spectrum conforming to the reference, and by the activity assay.”
  • “Protein pattern by SDS-PAGE consistent with the reference, with the molecular-mass markers reported.”
  • “Specific activity reported as units per milligram of protein, with the protein method named.”
  • “Loss on drying ≤5.0%; heavy metals and microbiology as listed; particle size ≥95% through 40 mesh.”
  • “Single enzyme preparation; carrier declared; no other protease activity added.”

Five questions before qualification

  1. Which strain produced this lot, and which unit definition and assay conditions are on the certificate?
  2. Can you provide the raw activity data, the standard curve and the assay worksheet, not only the final U/g?
  3. Can you provide the SDS-PAGE image with markers and the protein load, and the protein result with its method?
  4. What is the carrier, and is any other protease activity present in the preparation?
  5. If the lot is disputed, will you accept a joint re-test on the retained sample?

Five direct answers amount to an identity file. A single activity figure does not. The product hub carries the catalog specification; the grades page explains what the activity per gram fixes; the comparison with nattokinase shows why another protease's unit cannot stand in for this one; the bromelain page is the reference point for one of the common blend partners; the quality page describes how the evidence is kept.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation