What the COA for serratiopeptidase actually contains
A serratiopeptidase certificate is readable only when the activity line carries its method: the casein Folin assay, the assay pH, the temperature, the incubation time and the unit definition. The catalog specification is ≥20,000 U/g, with identification, loss on drying, heavy metals, microbiology and particle size released against the limits below. The batch COA confirms those limits for a particular pack; it does not turn the catalog figure into a result.
A serratiopeptidase figure in U/g is a rate on casein under named conditions, so the certificate has to carry the unit definition, the substrate and the assay pH beside the number.
Reading the certificate line by line
One row on this certificate decides the sale and several decide whether the powder can be used. Activity is the commercial parameter; identification decides whether that activity belongs to the named enzyme; moisture, metals and microbiology decide whether the lot can be released. Each row needs the method beside the limit, because “conforms” is a conclusion rather than a measurement.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White to off-white, free-flowing powder |
| Identification | IR spectrum and activity assay | Conforms to the reference |
| Serratiopeptidase activity | Casein substrate, Folin-Ciocalteu colour | ≥20,000 U/g |
| Loss on drying | Gravimetric | ≤5.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
The identification row deserves a second look. An IR spectrum of a protein is dominated by the amide bands, and the activity assay responds to any protease that hydrolyses casein. Together they are a reasonable release gate, but neither one alone separates serratiopeptidase from a blend of other proteases. The identity page describes the tests that do.
What the U/g figure measures
A unit per gram is a rate, not a concentration. In the casein Folin assay the enzyme is incubated with casein, the reaction is stopped, and the soluble peptides are coloured with Folin-Ciocalteu reagent and read against a tyrosine standard. One unit is the amount of enzyme that releases 1 µg of tyrosine per minute under the conditions the method names. The pH, the temperature and the incubation time therefore sit inside the definition, not outside it.
Method sheets in circulation do not all use the same conditions, so the same nominal figure can describe different amounts of activity. The table shows three definitions in circulation; none is wrong, and none converts into another by arithmetic.
| Assay conditions | Unit definition | Consequence |
|---|---|---|
| pH 7.5, 30 °C | 1 µg tyrosine released per minute from casein | Lower temperature, slower rate |
| pH 7.4, 37 °C | 1 µg tyrosine released per minute from casein | A different point on the pH and temperature curve |
| pH 8.0, 37 °C | 1 µg tyrosine released per minute from casein | A third rate, on the same substrate |
The result is normally reported per gram of preparation as sold, not per gram of protein. A powder at 20,000 U/g that contains little protein is not the same material as a powder at the same figure built on more enzyme and less carrier. State whether the figure is per gram as sold or corrected for moisture, and put the loss on drying beside it so the reader can see the basis.
Limit, method and measured result
The limit is the acceptance boundary. The result is what the laboratory measured on that lot. Both belong on the page, in separate columns, and the method belongs next to them. A result column filled with the specification range is not a result; it is a copy of the gate.
| Parameter | Release limit | Result column |
|---|---|---|
| Activity | ≥20,000 U/g | A measured figure with the method and unit definition |
| Identification | Conforms | The IR spectrum reading and the activity result behind the statement |
| Loss on drying | ≤5.0% | A measured percentage |
| Heavy metals | Per element | A measured figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
| Particle size | ≥95% through 40 mesh | The measured percentage through the sieve |
For an enzyme the activity result is the line that can fail while everything else passes. Moisture, metals and microbiology are contamination gates; activity is the product itself. A certificate that reports activity without the method has told the buyer the number but not what it means.
Lot-to-lot variation
Fermentation, recovery and drying move the activity. The producing organism is Serratia marcescens, and the fermentation yield depends on the strain, the medium and the run. Downstream steps concentrate or dilute the enzyme, and the final standardisation sets the units per gram.
Standardisation often means blending fermentation batches to a declared activity. That is legitimate, and it makes homogeneity and sampling part of the release decision: a blend has to be uniform enough that the sample tested represents the pack. The certificate should identify the blended lot, and the retained sample should come from the same blend.
Colour is a weak signal. White to off-white covers a wide range, and a slightly darker powder can still meet every chemical line. The trend across lots is more useful than one reading: activity drifting toward the floor, loss on drying climbing, or a new band on a protein gel. The lot code on the certificate should match the pouch, the drum and the retained sample.
When an outside laboratory is warranted
Order an independent test for a new source, a first shipment into a regulated market, a suspected blend, or a disputed result. The useful panel is activity by the same method the specification names, protein content, SDS-PAGE for the molecular-mass band, IR for the reference spectrum, loss on drying, the heavy-metal panel and microbiology. Protein content plus activity gives the specific activity; that ratio is the quickest check on a dilution.
Ask the laboratory to state its detection limit and its recovery for each screen. A “not detected” line without a limit is evidence about the method, not about the sample.
Chain of custody matters. The sample tested should be the sample retained, and the report should name the lot.
Six lines for a supplier comparison
Put six lines side by side: name, CAS number, EC number and source organism; activity with the method and unit definition; identity evidence, including the IR reading and the protein band; loss on drying; heavy metals and microbiology; pack size and lot code. Two quotations that agree on “20,000 U/g” but differ on the method are not describing the same powder.
The second layer is traceability. The certificate should say who made the lot, which strain and process were used, whether a carrier was added, and which milling step produced the 40 mesh powder. The catalog specification sits on the serratiopeptidase product page; the unit definition is set out on the methods page; the release workflow is described on the quality page. The grades page explains what changes when the activity per gram changes.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation