03 Stability

Serratiopeptidase activity is the shelf-life measure, not the appearance

Technical document 03 · Reviewed 2026-11-19 · Serratiopeptidase

On this page
  1. The powder: moisture, heat and the sealed pack
  2. In solution, the enzyme digests itself
  3. What drives the loss
  4. A stability protocol for the ingredient
  5. The dosage form decides the exposure
  6. How the shelf life is set

Serratiopeptidase loses activity with heat, moisture and time, and the loss is usually invisible. The catalog powder is released at ≥20,000 U/g with loss on drying ≤5.0%; the shelf life is assigned from stability data for the exact pack and storage condition, measured by the same casein assay that released the lot. A colour change is not the signal to watch; the activity result is.

In one line

Activity disappears before appearance changes, so the shelf life has to rest on a validated activity assay rather than on the look of the powder.

The powder: moisture, heat and the sealed pack

The loss-on-drying limit of ≤5.0% is a release gate, not a storage allowance. Once a foil pouch is opened, the powder can pick up moisture from the air, and the activity falls as the water content rises. The process is not visible: the powder still flows, the colour is unchanged, and the certificate still describes the lot as it was packed.

Heat accelerates the loss. A sealed pack held in a normal warehouse is usually acceptable; a hot loading bay, a vehicle roof or a warehouse corner next to a heater is not. Cold storage can help a long hold, but a cold pack should be allowed to reach room temperature before it is opened, so that condensation does not form on the powder.

The pack is part of the stability specification. The 1 kg foil pouch and the 25 kg fiber drum with its inner liner are moisture barriers, and the seal is the weak point. A pouch that has been folded over is not resealed in the same sense as a heat-sealed pack; the headspace now holds humid air, and the activity starts to decline from that moment.

In solution, the enzyme digests itself

The powder dissolves in water to a clear to slightly turbid solution. In that solution the enzyme is a substrate for itself: a protease can hydrolyse its own peptide bonds, and the activity falls even at a favourable pH. Temperature, pH, metal ions and time all act at once, and a solution that is clear at the start can lose a large part of its activity during an overnight hold.

A liquid or a ready-to-drink process adds a heat load through pasteurisation, hot fill or sterilisation. A bulk-powder stability result does not describe that process. If a liquid is unavoidable, protect it from light, hold it at the pH the stability data covers, keep dissolved oxygen low, and validate the hold time before filling. Freeze-thaw cycles are not a storage solution: they can concentrate solutes and denature the protein.

The same logic applies to a wet granulation. The water, the heat of drying and the mechanical work all act on the enzyme, and the activity after granulation is the number that matters for the formula, not the activity of the ungranulated powder.

What drives the loss

Factors that move serratiopeptidase activity during storage and processing
FactorWhat it doesControl
HeatAccelerates unfolding and activity lossControlled store; cool process; short heat exposure
MoistureRaises molecular mobility; activity fallsSealed foil; liner; desiccant where justified
pHMoves the enzyme away from its working rangeValidate the matrix pH; avoid strongly acidic mixes
ChelatorsStrip the zinc the enzyme depends onCheck EDTA and chelating excipients
OxidationDamages the protein and the required metal centreLow oxygen; sealed pack; antioxidant review
Shear and compressionHeat and local stress during tabletingProcess controls; assay after compression
LightSlow contribution compared with heat and moistureOpaque pack; dark store

The chelator row is specific to this enzyme. Serratiopeptidase is a zinc metalloprotease, and calcium contributes to its structural stability. A formulation that removes free metal ions, or a premix that presents them in a form the enzyme cannot use, can reduce activity without any change in the certificate. The interaction is a formulation question, and it should be tested in the matrix rather than assumed from the powder data.

A stability protocol for the ingredient

A useful protocol names the pack, the storage condition, the time points and the tests. Long-term storage at 25 °C/60% relative humidity and intermediate storage at 30 °C/65% relative humidity cover the warehouse; accelerated storage at 40 °C/75% relative humidity stresses the pack. A light-exposure arm covers the failure mode that a dark incubator misses.

Activity is the primary stability-indicating measurement, and it must be run by the same method as release. A trend built from two different assays is not a trend. Test loss on drying, appearance and microbiology at each point as well, because a lot can fail microbiologically while the activity holds.

For a tablet, a capsule, a coated pellet or a stick pack, repeat the work in the finished form and at the process steps that expose the enzyme to heat or water. The report should show the individual results and identify the pack, the lot family and the method. A summary that says “stable” without the figures is not evidence.

The dosage form decides the exposure

A capsule has low water activity, but the shell and the excipients can still transfer moisture, and a hygroscopic filler can raise the water content of the fill. Check activity and loss on drying at release and after storage, not only the appearance of the capsule. A tablet adds compression heat and, if it is wet-granulated, a water and drying step; the activity after tableting is the number that belongs in the specification.

Many serratiopeptidase products are presented in an enteric-coated capsule or as enteric-coated granules. The coating is there because the enzyme is a protein and is labile in the stomach; the coating process itself adds solvent, heat and mechanical stress. Measure the activity after coating, and check that the coating does not interfere with the assay's extraction step.

Acidic ingredients, chelating ingredients and mineral premixes are the usual compatibility questions in a blend. A stick pack adds the seal and the foil as failure points. An overage is a formulator's decision about the label and the stability margin; it does not repair a pack that lets moisture in.

How the shelf life is set

We do not publish a single shelf-life number for serratiopeptidase, because the pack and the storage condition set it. The assigned retest period belongs on the specification and is supported by the stability file for that pack. A number without a pack, a condition and an activity method is not a shelf life; it is an assertion.

After the retest period, re-assay the retained sample before extending use. Do not extend by assumption, and do not carry a bulk figure across to a repacked container. The product hub lists the standard packs; the COA page covers the release tests; the MOQ page covers pack and lead time; the methods page describes the assay; the quality page describes the release workflow.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation