What the COA for pancreatin actually contains
The certificate for a pancreatin lot reports the three USP activities — amylase, protease and lipase — each with the substrate and conditions that define its unit, the ratio between them, loss on drying, heavy metals, microbiology and particle size. The limits below are the catalog specification; the batch COA is the document that confirms a particular pack. An activity figure without its unit definition cannot be compared with any other certificate.
A pancreatin certificate is complete only when each activity carries its USP unit, substrate and conditions, and the ratio to the other two is reported beside the individual results.
The certificate as a test report
A certificate is a test report before it is a commercial document. Every parameter needs what was measured, which method produced the number, and the limit the lot was released against. A line that says only “conforms” asks the reader to trust a conclusion. Pancreatin needs more evidence than most powders, because one material carries three activities.
| Parameter | Method | Release limit |
|---|---|---|
| Identification | Infrared spectrum and the three activity assays | IR conforms; all three activities present |
| Amylase | USP assay; starch, pH 6.8, 25 °C | ≥25 USP U/mg |
| Protease | USP assay; casein, pH 7.5, 40 °C, 60 min | ≥25 USP U/mg |
| Lipase | USP assay; olive oil, pH 9.0, 37 °C | ≥2 USP U/mg |
| Loss on drying | USP general chapter 731; vacuum, 60 °C, 4 h | ≤5.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
The activity rows define the product; the identification row only means something when it includes them, because an infrared spectrum can match a reference while the lipase has been lost.
What one USP unit means, and the basis of the number
The three units are rates, not masses. One USP unit of amylase decomposes starch at 0.16 µEq of glycosidic linkage per minute; one unit of protease liberates, per minute, peptides not precipitated by trichloroacetic acid that match the absorbance of 15 nmol of tyrosine at 280 nm; one unit of lipase liberates 1.0 µEq of acid per minute at pH 9.0 and 37 °C. The substrate, pH, temperature and standard are part of each definition; a USP unit is not a FIP or house unit.
The activity is reported per milligram of powder as weighed. With loss on drying up to 5.0%, an as-is and a dried-basis figure can differ by about 5%; the certificate should state the basis and print the loss-on-drying result beside it.
The catalog follows the USP activity definitions, not full monograph compliance. The monograph also sets a fat limit, microbial absence and a storage condition; if the lot is bought against it, ask for those lines too.
Release limit versus batch result
The release limit is the boundary; the batch result is the measurement. Both belong in separate columns, with the method beside them. A result column that repeats the specification is a copy of the gate, not evidence that it was passed.
| Parameter | Release limit | Result column |
|---|---|---|
| Amylase | ≥25 USP U/mg | A measured figure, with the assay and the standard |
| Protease | ≥25 USP U/mg | A measured figure, with the assay and the standard |
| Lipase | ≥2 USP U/mg | A measured figure, with the assay and the standard |
| Ratio | Not fixed by the minima | The three results, and the ratio calculated from them |
| Loss on drying | ≤5.0% | A measured percentage |
| Heavy metals | Per element | A measured figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement |
The activity limits are one-sided, and the minima do not fix the ratio. A lot at 200 amylase, 200 protease and 2 lipase U/mg passes every minimum but carries 100 amylase units per lipase unit, eight times the 12.5 in the 25/25/2 ratio; specify a target ratio and a tolerance, not only three floors. Near a limit, ask for the raw record: sample weight, blank, standard, replicate titres and calculation.
What moves between batches
Pancreatin is a tissue extract, so the starting material moves first. The monograph allows hog or ox pancreas, and the species can change the protein profile, the colour and the natural activity ratio. Gland quality, extraction and concentration add variation; standardisation evens out the total while the ratio, the fat content and the protein load still move.
The monograph permits dilution with lactose, with sucrose containing not more than 3.25% starch, or with lower-activity pancreatin, so the carrier is part of the lot history. A lactose-diluted lot and a concentrate at the same amylase figure are not the same powder: the diluent adds mass and a milk-derived allergen that the label has to declare.
Colour and odour are less quantitative and often more revealing. Residual fat can oxidise, and a rancid note points to an ageing lot even when the activities pass. Lipase drifting towards 2 U/mg while amylase stays high, loss on drying climbing or fat approaching its limit together describe a material that is changing.
When to order an outside test
Order an independent test for a new source, a first shipment into a regulated market, a pharmacopoeial purchase, a disputed result or a method mismatch. The panel is the three USP activities on one sample, infrared identification, loss on drying, fat, heavy metals, microbiology and particle size. An outside figure is comparable only if the laboratory used the same assay; change the substrate, pH, temperature or standard and the number moves for reasons unrelated to the lot.
Ask for the method, the reference standard and the reporting limits with each result; for a pharmacopoeial purchase, test the full monograph rather than the triad. The sample tested should be the sample retained, and the report should name the lot. When a result is contested, give the referee the retained sample, the certificate and the specification, and ask both laboratories for the raw titration; a second run by the same method is stronger than a second opinion on the first report.
What to compare between suppliers
Compare six lines: the three results and their ratio; the unit definitions and the monograph edition; the species and tissue record; the carrier; loss on drying, fat and microbiology; the pack and lot code. Two certificates that both read “25/25/2 USP U/mg” can describe different ratios, species and carriers.
The activity lines are the first comparison, not the last. The catalog position is on the pancreatin product page; the ratio question continues on the grade page and the pancreatin versus pancrelipase comparison; the evidence that the powder matches the certificate is on the identity page; the assays are described in the methods section; the release workflow is on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation