01 COA & batch testing

What the COA for neutral protease actually contains

Technical document 01 · Reviewed 2026-11-19 · Neutral Protease

On this page
  1. What each row has to establish
  2. The unit is a rate, and the method defines it
  3. Where the limit ends and the result begins
  4. Why two lots at the same U/g can differ
  5. When to use a second laboratory
  6. Six lines for a supplier comparison

A neutral protease COA is a record for one lot, and most of its rows are routine: colour, pH, moisture, mesh, heavy metals and microbiology. The activity row is different. “≥50,000 U/g” is a measurement whose meaning depends on the assay that produced it, so the substrate, pH, temperature, time and standard have to appear with the number. The limits below are the catalog specification; the certificate is the evidence for a particular drum of neutral protease powder.

In one line

The activity figure on a neutral protease COA is a result from one method, so the unit definition, the casein substrate and the assay conditions have to travel with it.

What each row has to establish

For every parameter, the reader needs to know what was tested, how it was tested and which limit applied. The activity row needs one more item: the conditions of the assay. A certificate that gives the number but not the method records an opinion rather than a measurement.

Catalog release limits · neutral protease from Bacillus subtilis
ParameterMethodRelease limit
AppearanceVisualOff-white to light brown, free-flowing powder
Neutral protease activityCasein substrate, Folin–Ciocalteu colour; conditions printed on the COA≥50,000 U/g
pH (1% solution)Potentiometry6.5–7.5
Loss on dryingGravimetric≤8.0%
Particle sizeSieve analysis≥95% through 40 mesh
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤10,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

Look closely at two rows. The activity method cell should point to the unit definition, since U is a rate. The microbiology cell should identify the tests and the sample size; “absent” is only meaningful when the method is named.

The unit is a rate, and the method defines it

A neutral protease unit is not a mass of protein. It measures how much enzyme is needed to produce a stated change in a stated substrate within a stated time. A common definition uses casein at pH 7.0 and 40 °C: one U releases 1 µg of tyrosine equivalent per minute, read by Folin–Ciocalteu against a tyrosine standard. Other laboratories hold pH 7.5 and use 30 °C or 37 °C. Each definition is valid inside its own method; a figure from one cannot be read as a figure from another.

The activity entry · what a complete method states
ElementRequirementEffect if omitted
UnitU per gram of preparationA figure per gram of protein is a different quantity
SubstrateCasein, with grade and concentrationAnother protein exposes other bonds
pHThe pH used, for example 7.0 or 7.5The rate changes across the pH profile
Temperature30 °C, 37 °C or 40 °CThe rate depends on temperature
IncubationMinutes before the reaction is stoppedOnly part of the curve is linear
DetectionFolin–Ciocalteu or an equivalent colour reactionA different chemistry gives a different scale
StandardTyrosine, with the lot and the curveCalibration shifts every result
BasisAs-is, or corrected to dry solidsMoisture changes the denominator

Moisture deserves its own note. If the result is as-is and loss on drying is 8.0%, the dry-solids figure is not the same number; the gap is roughly the water content. Ask which basis is printed. Protein and specific activity form a second pair: units per milligram of protein tell a buyer whether the activity comes from a concentrated enzyme or from more powder, and that ratio is rarely printed unless it is requested.

Where the limit ends and the result begins

The limit is the pass mark; the result is the measurement. A certificate that prints only “≥50,000 U/g” under “result” has restated the specification. The actual figure matters because a lot that passes just above the floor has less room for process loss than one that passes well above it, even though both are released.

Activity is a one-sided test, so the two lots above are equally compliant. When a result sits near the line, request the raw data: sample weight, blank, absorbance, standard curve and the calculation. Ask for the release date and the shelf-life basis too. A drum that arrives six months after release carries the activity that is left, not the activity measured on release day.

Why two lots at the same U/g can differ

Fermentation conditions set the starting point: strain, inoculum, medium, aeration and harvest time change the enzyme mixture in the broth. The downstream train — recovery, concentration, drying — decides how much of that mixture becomes powder, and the last step is a blend that brings the activity to the declared figure. The spread between lots is therefore partly biological and partly a standardisation choice.

Drying and milling add two more variables. A powder with more moisture reads lower per gram at constant dry solids, and a hot mill can damage activity before the sieve is reached. Colour and smell are less precise but still informative: a darker brown or a stronger fermentation note may follow a longer hold or a hotter dryer while the assay passes. The method can drift as well. If the substrate lot, pH or incubation time changes between certificates, both figures may say U/g and still not be comparable.

When to use a second laboratory

Order an outside test for a new source, a first shipment into a regulated market, a claim that rests on the activity figure, or a disagreement over a result. The panel to request: your own activity method run on the retained sample, protein, moisture, ICP-MS metals, a micro count and a gel-electrophoresis protein pattern.

Make the outside laboratory follow the specification's substrate and conditions exactly. If it does not, the two results compare methods, not material. A metal reported as “not detected” needs its reporting limit beside it; without that number the line describes the instrument, not the lot. The sample tested should be the sample retained, and the lot code should appear on the certificate, the pack and the laboratory report.

Six lines for a supplier comparison

Compare the unit definition, the substrate and conditions, the measured activity and its method, protein and specific activity, moisture and particle size, and the carrier plus production strain. Agreement on 50,000 U/g is not agreement on the other five lines; the divergence usually appears at the first blend trial.

The second question is traceability. A buyer should be able to read one lot code on the certificate, the pack and the retained sample. The certificate should also name the organism that produced the enzyme, since source is part of identity for a food enzyme. The catalog numbers sit on the product page; the grades page covers dilution, the U versus AU note covers the unit, the identity page covers the evidence, and the quality page covers release.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.