50,000 U/g or a dilution: choosing a neutral protease grade
The standard neutral protease grade is a 40-mesh powder at ≥50,000 U/g. A lower-activity dilution and a granulated form can be made on request. Each option changes the mass that delivers a unit target, the carrier that appears on the label and the amount of dust in the room. None of them changes the enzyme or the unit.
A grade is a choice of concentration, particle form and carrier; the enzyme and its unit stay the same while the formula and the label change.
Concentration first, then mass
A formula fixes the number of units it needs per capsule or per sachet. The catalog powder supplies those units at 50 U per milligram. If a dilution supplies 25 U per milligram, the same target needs twice the powder. That is the whole arithmetic, and it drives everything else: the fill weight, the number of capsules, the size of the stick pack and the space the enzyme takes in a blend.
The concentrate suits a small inclusion, which is usually what a capsule wants. A dilution suits a low unit target or a format that needs bulk, and it can make weighing more accurate because the scoop is larger. Granulation is a handling choice rather than a concentration choice: it improves flow and cuts dust, but it adds a process that can cost activity. If the organism or the unit changes, the offer describes another material, not another grade.
Three options, one unit definition
| Grade | Activity | What it is | Fits | Watch |
|---|---|---|---|---|
| Catalog powder, 40 mesh | ≥50,000 U/g | The standard grade; carrier declared on the COA | Capsules, tablets and blends with a small inclusion | Dust, static and small-dose weighing |
| Lower-activity dilution | Fixed in the specification | Standard powder extended with a named carrier | Stick packs and blends that need more bulk | Carrier declaration; segregation in the blender |
| Granulated | Same unit definition | Agglomerated particles | Tableting, sachets and low-dust rooms | Heat and moisture from the granulation step |
The three rows share a source, a unit and an assay. What separates them is concentration and particle structure. A dilution becomes a legitimate grade when the carrier is named and the lower activity is written into the specification; it is not a device for putting a 50,000 U/g label on a weaker powder.
What the powder does in the room
A 40-mesh powder passes openings of about 425 µm. It flows, it raises dust when poured and it carries a static charge that makes small weighings fussy. The dust is a health issue as well as a housekeeping one: enzyme powders are respiratory sensitisers, so local exhaust ventilation or a weighing booth belongs in the process description.
Granulation can cut the dust and improve flow, but the binder, the water or solvent, the drying temperature and the post-granulation milling all become part of the specification. Measure the activity after granulation; the base powder's figure does not describe the granule. With a dilution, check the particle size of the blend, not only of the enzyme, because a coarse carrier and a fine enzyme can separate in a hopper.
Fitting the unit target into the pack
Suppose a capsule is specified to carry 10,000 U. The 50,000 U/g powder supplies it in 0.2 g; at 25,000 U/g the same capsule needs 0.4 g. The second fill may be easier to weigh but harder to fit, and the carrier joins the ingredient list. Those are the real trade-offs behind a grade choice, not the size of the number on the certificate.
Stick packs and sachets also care about dispersion and mouthfeel, not only mass. A dilution can reduce clumping and help the pack empty cleanly, at the cost of more carrier and a longer declaration. Tablets care about flow and compression; a granulated grade may run where a fine powder bridges, but any aqueous step adds heat and water that the enzyme has to survive. In a blend with other enzymes, changing one component's concentration also changes the blend ratio and the uniformity of the smallest ingredient.
What the specification should say
- “Neutral protease (bacillolysin; EC 3.4.24.28) preparation from Bacillus subtilis, CAS 9025-39-2, ≥50,000 U/g.”
- “The U is defined by the casein assay; substrate, pH, temperature, time and standard are printed on the COA.”
- “Result reported as-is; loss on drying ≤8.0%; pH 6.5–7.5 in 1% solution.”
- “Carrier named and quantified; a dilution is specified separately from the concentrate.”
- “Particle size ≥95% through 40 mesh; granulated material to the agreed size.”
- “Activity re-measured after granulation, not inferred from the base powder.”
A grade change is also a document change. The specification, COA, label, blend calculation and stability summary all move together, while the unit definition stays put. Switching from the concentrate to a dilution without rewriting those documents creates two materials under one name.
When the answer is to keep the grade
Keep the 50,000 U/g grade when the label already declares that figure; diluting it would put the label and the certificate out of step. Keep the powder if it already flows, because granulation adds heat and moisture for no gain. Do not add a carrier that the label or the customer's specification excludes, and do not move to a higher activity if the resulting scoop becomes too small to weigh reliably.
Catalog data sits on the product page. The COA page sets out the release lines, the U versus AU page compares the units, and the MOQ page covers packs and order quantities.
In this document
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation