02.1 U vs AU

U vs AU: what a protease unit actually means

Technical document 02.1 · Reviewed 2026-11-19 · Neutral Protease

On this page
  1. Two scales and an ambiguous label
  2. The protein chooses the reaction
  3. Conditions move the number
  4. No factor can bridge two methods
  5. What the paperwork must state
  6. Pick the unit your specification can test

A protease unit is a rate tied to a method. U and AU come from different methods: U is normally a casein-based unit defined by the supplier, while AU is the Anson unit, normally measured on hemoglobin. The substrate, pH, temperature and the amount of tyrosine counted all change, so one figure cannot be translated into the other.

In one line

U and AU are two measurements, not two labels for one quantity; the substrate and conditions behind each one rule out a fixed conversion.

Two scales and an ambiguous label

What each protease activity unit measures
UnitSubstrateDefinition in common useUsual conditions
U/gCasein1 µg of tyrosine equivalent released per minutepH 7.0 and 40 °C in the common method
AU/g (Anson)Hemoglobin1 µmol of tyrosine released per minutepH 7.5 and 37 °C in the classic method
AU/g (house)Method-specificA supplier's own activity unitAs stated in the method sheet

No international body polices the letter U; each supplier's method sheet supplies the definition. AU usually points to Anson, but a catalogue may use it for a house unit with a different protein or incubation time. A number without its method is not a specification, whatever letter comes before the slash.

The protein chooses the reaction

Casein and hemoglobin differ in sequence, solubility and the peptide bonds they expose. A protease that performs well on casein may perform differently on hemoglobin, and the ratio between the two performances is not constant across preparations. Both assays use trichloroacetic acid to precipitate the intact protein and Folin–Ciocalteu reagent to colour the soluble peptides, so the reading depends on which fragments remain in solution as well as on the rate of bond cleavage.

The substrate lot matters too. A different casein preparation, a different degree of denaturation or a different hemoglobin batch can shift the result with no change in the enzyme. That is why the method sheet belongs in the specification and on the certificate, beside the unit.

Conditions move the number

Assay conditions and their effect on the reported figure
ConditionCommon settingsEffect on the figure
pH7.0 for the casein method; 7.5 for AnsonActivity varies across the pH profile
Temperature40 °C for U; 37 °C or 25 °C for AURate rises with heat until the enzyme denatures
Time10, 20 or 30 minutesLinearity holds for only part of the reaction
Amount countedMicrograms of tyrosine for U; micromoles for AUThe two definitions count different quantities
DetectionFolin–Ciocalteu colour, tyrosine standardThe calibration curve sets the scale

Two laboratories can both report U/g and still disagree, because each chose different settings inside the same family. That is a property of rate assays, not a sign of bad faith. The remedy is to write the settings into the specification and to ask for the raw record when a result falls near a limit.

No factor can bridge two methods

A conversion factor assumes the ratio between the two assays is constant for every preparation. It is not, because the protein, pH, temperature and counted amount all differ. Even the nominal arithmetic between a microgram and a micromole of tyrosine does not create a bridge: the two numbers were produced on different substrates under different conditions.

Within one scale, the total units convert exactly. A kilogram at 50,000 U/g holds 50 million U, and two kilograms at half the activity per gram hold the same total. That is useful for ordering and for blend calculations. It says nothing about the U-to-AU relationship. When a buyer needs the other unit, the only sound route is to run both assays on the same lot.

What the paperwork must state

A food enzyme supplied to a manufacturer in the EU must show its declared activity and unit alongside the name, a food-use statement, the lot and storage conditions. A unit without the method is an incomplete specification, and a figure without the unit is an incomplete label. The UK retained regime follows the same logic.

US labelling places enzyme activity in the specification column, not the nutrient column. It has no daily value and does not belong in the nutrition panel. If the enzyme still functions in the finished food, the ingredient list has to name it; the activity figure remains a specification and certificate item. Every market needs the same choice made explicit: is the figure the activity at release, or the activity promised at the end of shelf life? A label that leaves the choice open is making two promises at once.

Pick the unit your specification can test

For a new neutral protease specification, U/g on casein is the practical choice: the method is widely used, the substrate is defined and most suppliers can reproduce it. Keep AU when a legacy formula, a customer specification or an existing label is written in Anson units; translating the number would create a new material on paper.

If a supplier offers only the other unit, ask for both assays on the same lot and read the pair as the evidence. Do not pick the unit that yields the larger number, and do not accept a catalogue conversion factor as a specification. Put the method reference, the conditions and the basis beside the unit. Grade choices are compared on the grades page; certificate lines are on the COA page; identity evidence is on the identity page; the catalog entry is on the product page; and the assay vocabulary is in the assay glossary entry.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation