02 Grade comparison

Maltase grades: the 80 mesh powder and the granule

Technical document 02 · Reviewed 2026-11-20 · Maltase

On this page
  1. Why there is no assay percentage
  2. The powder and the granule
  3. 80 mesh, flow and dust
  4. Working out the charge weight
  5. Turning the choice into specification lines
  6. When granulation works against you

Maltase has one catalog activity, ≥100,000 U/g, and one standard particle form, an 80 mesh powder; a granulated version is offered for dust control. There is no purity percentage to choose between, because an enzyme preparation is a mixture of active protein, other fermentation proteins and carrier. The grade conversation is therefore about carrier, mesh and the units the batch actually needs.

In one line

A maltase grade is an activity figure carried on a named powder, so the U/g number alone does not say what a gram will do in a blend.

Why there is no assay percentage

An enzyme powder cannot be described by a single content figure. The active protein is only part of the mass; the rest is other fermentation proteins, residual medium and the carrier used to reach the declared activity. A certificate can report protein, but protein is not activity, and neither number is a purity grade. Buyers specify the preparation by four attributes instead: units per gram, carrier, mesh and source organism.

Two powders can both read “maltase, 100,000 U/g” and still behave differently. One may carry more active protein per gram and less carrier; the other may be extended with carbohydrate to the same number. Both can be legitimate products, but they are not interchangeable gram for gram. The COA page shows how each is certified.

Four attributes of a maltase preparation
AttributeWhat it controlsWhy it matters
Activity targetUnits in each gramCharge weight and overage
CarrierThe mass around the enzymeLabel entry, moisture, flow
MeshParticle sizeWetting, mixing, dust
OrganismThe source of the enzymeIdentity and market route

The powder and the granule

The 80 mesh powder is the standard grade. Granulation changes how the powder handles, not what the enzyme is. The granule exists to control dust, and its activity is assayed after the process; it is not inferred from the starting powder. Water and heat are part of most granulation processes, so the granule can finish below the activity of its starting powder.

Catalog forms and the formula consequence
FormActivityParticle sizeConsequence for the formula
Standard powder≥100,000 U/g≥95% through 80 meshFast wetting; lightest charge; dust
GranulesMeasured after granulationGranulatedLess dust; slower wetting; process loss

A lower-activity dilution is not in the catalog. A project that needs one is asking for a new specification — different carrier, different target, a new label entry and a fresh qualification — not a different pack size. That work should be scoped as development, with its own trial and its own certificate.

80 mesh, flow and dust

At ≥95% through 80 mesh, roughly 177 µm, the powder disperses quickly in water and gives the clear to slightly turbid solution the specification describes. The same fines that speed wetting remain airborne. Because enzyme dust can sensitise the airway, the handling plan needs extraction at the source, closed transfers and a suitable mask; hazard wording sits in the SDS.

Granules reduce the dust and slow the wetting. A production operator who handles kilos a day is the natural user; a stick pack that has to disperse in seconds is not. The powder is also hygroscopic: an open pouch takes up water, particles cake, and the loss-on-drying figure climbs. In practice the grade includes a sealed pack and a dry store, even though neither appears on the certificate.

Working out the charge weight

Start from the units the batch needs. A 500 kg blend dosed at 20,000 U per kilogram requires 10 million units, which is 100 g of the 100,000 U/g powder. Within one unit scale the arithmetic is exact; it says nothing about another enzyme or another unit.

At production scale 100 g is an easy addition; in a 5 kg pilot the balance and the mixer both struggle with a charge that small. A granule does not solve that problem, because it carries the same units per gram as the powder it came from. The practical answers are a larger trial batch, a pre-blend made by the customer, or a custom specification developed and qualified separately.

Two details belong beside the arithmetic. First, the label basis: is 100,000 U/g the release figure or the end-of-shelf-life figure? Second, the maltose in the blend. A dry blend does not let the enzyme act, but once water is added — in a wet granulation, a syrup or a drink mix — maltase will hydrolyse maltose and maltooligosaccharides, and the sugar profile can move. That may be the intended process or an unwanted change; either way, it belongs in the trial.

Turning the choice into specification lines

Ten lines: the activity and its method; identity by assay; protein or specific activity; moisture at ≤8.0%; mesh at ≥95% through 80 mesh; carrier; organism and strain; form; the labelled basis; storage. If a line cannot be measured at goods-in, it does not belong in a purchase specification.

Write the activity as a minimum and place the method appendix under document control. If the maltose source, the pH or the glucose detection changes, two results carrying the same U/g label are no longer comparable. Vocabulary is defined in the specification glossary entry; the checks that keep a granulated lot honest are on the identity page.

When granulation works against you

A stick pack that must disperse in seconds gains nothing from a granule that wets slowly. A formula with no dust problem gains nothing from the extra process step, and a heat-sensitive blend gains nothing from a granulation that removes activity before the powder reaches the customer.

Scale adds a third case. Dust control is a real benefit, but the granule is still an additional material to qualify, declare and store once the line is enclosed. Pick the form for the routine handling, not for the trial run.

The catalog is on the maltase product page; packs and lead time on the MOQ page; activity retention on the stability page; the amylase comparison on the maltase vs amylase page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation