What the COA for maltase actually contains
A maltase certificate is built around one kinetic line: activity in units per gram, measured by the glucose released from maltose. The other lines describe the powder that carries that activity — appearance, loss on drying, mesh, metals and microbiology. The catalog floor is ≥100,000 U/g, and the batch document has to show the measured result, the method and the conditions behind it.
A maltase result is a rate, so the certificate has to put the maltose substrate, the glucose detection and the assay conditions beside the U/g figure.
The certificate as a release record
Every row should say what was measured, how the laboratory measured it, and the acceptance limit for that measurement. A row that reports only “conforms” records a conclusion and hides the evidence. On an enzyme certificate the activity line carries the most weight, because it is the only line that measures what the powder does rather than what it contains.
| Parameter | How it is run | Limit |
|---|---|---|
| Appearance | Visual inspection | Off-white to light tan, free-flowing powder |
| Maltase activity | Maltose substrate; glucose released, reported in U/g | ≥100,000 U/g |
| Identification | Activity assay against the reference | Conforms |
| Loss on drying | Gravimetric | ≤8.0% |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count plus absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
CAS 9001-42-7 identifies the enzyme as a substance, not the lot in the drum. A usable certificate also carries the lot number, the preparation, the carrier and the production organism, because those four define the powder that was actually tested. Identification here is functional: the activity assay is the identity test, and there is no separate chromatographic identity line to fall back on.
What one unit means, and what the basis changes
A unit is the amount of enzyme that releases one micromole of glucose from maltose per minute under the conditions written in the method. The pH, the temperature, the maltose concentration and the way glucose is detected all decide how many units a gram appears to contain. The catalog names the substrate and the unit; the assay pH and temperature belong in the method appendix and on the technical data sheet.
Glucose detection is usually enzymatic and colorimetric: the released glucose is oxidised and the colour is read against a standard curve. A blank is run without enzyme or without substrate, so that glucose already present in the powder or the carrier is not counted as enzyme activity. Without the blank, a sweet carrier can make a weak lot look strong.
The assay is reported per gram of powder as sold. At the 8.0% loss-on-drying limit, a 100,000 U/g result as-is corresponds to about 108,700 U/g on a dry basis. The arithmetic is simple, but the two figures describe different powders, and a specification that mixes them can reject a conforming lot. The activity row should carry the basis explicitly, with the moisture result in the next column.
A dilution made before the assay is a third basis question. The laboratory may dilute the powder to bring the reaction into range, but the result is calculated back to units per gram of powder as sold. If the buyer dilutes the powder into a blend, that blend is a new material and needs its own activity check; the certificate for the concentrate does not certify the blend.
A floor, a measured result and the spread
≥100,000 U/g is a one-sided limit. A lot released at 103,000 U/g and a lot released at 180,000 U/g both pass, yet they leave different room for activity loss in storage and in a process. The useful number is the measured result; the limit only says the lot cleared the gate.
The figure can be checked only if the certificate names the method, the assay conditions and the release date, and says whether it applies at release or at end of shelf life. A result close to the floor is not a comfortable margin if the pack is opened in a humid room or the blend is held warm. Ask also for the relative standard deviation of the assay; where repeatability is poor, a figure just above the floor is within the noise of the method.
Where lot-to-lot spread comes from
Fermentation variables — inoculum, medium, oxygen supply and harvest time — shift the protein mix in the broth, and the downstream concentration decides how much of that mix reaches the powder. Standardisation with a food-grade carrier then fixes the activity per gram at the declared target. Two lots can meet the same floor and still differ in protein content, colour and behaviour in a blend.
Moisture and thermal history change the number after the broth is harvested. A lot dried to a higher residual moisture weighs more water per gram, so its as-is activity is lower even with intact enzyme; heat at the mill can also knock activity down before sieving. Mesh is a finishing parameter: a new mill or sieve can move the 80 mesh result while the enzyme itself is unchanged.
Colour is a weak signal and deserves a note rather than a rejection. A darker tan can follow a longer dry without any assay failure. A trend across lots is more informative: activity drifting toward the floor, loss on drying climbing, or a growing glucose blank. The certificate, the shipping pack and the retained sample should all show one lot code.
When an outside assay is worth buying
An outside laboratory is worth paying for when the source is new, the market is new, a result is contested, or a label statement depends on the activity figure. A narrow panel is enough: a maltose assay on the retained sample, protein, moisture, the metal panel and the micro count. A protein pattern against a reference lot adds a second, non-activity check on identity.
Method match is the whole point. The outside lab has to use the same maltose concentration, pH, temperature and glucose readout as the specification, or the comparison is between methods rather than powders. A report in “units” from an assay run on p-nitrophenyl glucoside is not a second opinion on a maltose-based U/g result; it is a different measurement. Ask for the blank, the standard curve and the detection limit, and require the lot code on both the sample and the report.
Six lines for a supplier comparison
Set the unit and method, the measured result and its basis, protein or specific activity, loss on drying and mesh, the metal and micro panels, and the organism with the carrier side by side. Agreement on the headline U/g can hide disagreement on five other lines, which means the powders are not interchangeable. The difference shows up in the first trial rather than in the offer.
The catalog values are on the maltase product page. For identity evidence, see the identity page. Method families are collected under methods, and the quality page describes the release workflow.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation