Lysozyme grades: activity, salt form and particle size
Lysozyme is supplied as a hydrochloride powder specified at ≥20,000 U/mg, with the salt form, the activity and the particle size making up the grade. A granulated form is available on request; a lower-activity dilution is a separate custom specification, not a packing variant. The salt question is larger than the other two and has its own page: lysozyme against lysozyme hydrochloride.
A lysozyme grade is an activity figure plus a salt form and a particle size, and changing any one of the three changes the dose and the label.
Why an enzyme has grades but no purity figure
A crystalline additive can be sold at 98% or 99% because the assay compares the molecule with everything else in the drum; a lysozyme preparation cannot be described that way. The powder contains the enzyme, the remains of the extraction, and any carrier used to standardise the activity, so the useful description is a declared activity plus the identity of the salt, the source and the particles.
That is why two suppliers can both offer “lysozyme” and mean different materials: one sells a hydrochloride concentrate at ≥20,000 U/mg, the other a diluted powder at a fraction of that figure, and the second carries several times the mass for the same number of units. Neither is wrong: they are different grades with different jobs and specifications.
| Property | What it controls | Where it shows up |
|---|---|---|
| Activity (U/mg) | How many units a milligram delivers | Dose weight, label claim, overage |
| Salt form | Chloride content, mass and solution pH | Ingredient name, weigh-up, label |
| Carrier | What the activity is diluted on | Ingredient list, moisture, flow |
| Particle size | How the powder flows and dissolves | Blend uniformity, dust, mixing time |
| Physical form | Powder or granule | Dust control, dispersion rate |
| Source | Declared source and production stream | Identity file, allergen statement |
The grade options side by side
The standard grade is a white to off-white 40 mesh powder at ≥20,000 U/mg, in the hydrochloride form. A granulated version is made on request. A preparation sold simply as lysozyme is a separate specification, not a packing variant of the standard grade.
| Option | Activity | Form | What changes in the formula |
|---|---|---|---|
| Standard hydrochloride powder | ≥20,000 U/mg | 40 mesh powder | Smallest dose weight; the catalog grade |
| Custom lower-activity dilution | Agreed in the specification | 40 mesh powder | Larger dose weight; the carrier becomes an ingredient |
| Granulated hydrochloride | Agreed in the specification | Granules | Less dust; slower dispersion; check the granulation loss |
| Free-base lysozyme | Separate specification | Powder | Different salt, mass, pH and label name |
The activity figure is comparable only when the unit is. A U/mg from one supplier and a unit tied to a different wavelength or cell charge from another are not the same measurement. The COA page sets out the elements the unit definition has to carry.
Powder, mesh and dust
The standard particle size is ≥95% through 40 mesh, a free-flowing powder that blends into a dry mix and dissolves readily in water. The hydrochloride gives a solution with an acidic pH: the EU additive specification for a 2% aqueous solution sets pH 3.0–3.6, which belongs in the handling notes and in any pH-sensitive formula.
Fines are what make the powder dissolve quickly, and they are also what make it dust. Enzyme powders can be respiratory sensitisers, so dust is a handling question as much as a processing one: the safety data sheet carries the hazard statements, and the controls are local exhaust ventilation, closed transfer and the right mask. Granulation trades dispersion speed for dust control. A granule wets more slowly, so a stick pack that must disperse in seconds is usually built on powder, while a plant handling kilos a day may prefer granules to keep the air clean.
Whichever form is chosen, the granulation step itself removes activity, and the after-step figure belongs in the specification. A granulated grade is not the same powder pressed into a different shape; it is a new lot with its own certificate.
The arithmetic that decides the grade
Units are weight multiplied by activity. For every 200,000 U a formula needs, a 20,000 U/mg powder contributes 10 mg and a 10,000 U/mg dilution contributes 20 mg. The units are identical; the mass, the carrier and the label entry are not. A twofold dilution doubles the powder weight and adds one part of carrier for every part of enzyme powder.
Weighability usually settles the choice. A 10 mg charge is routine in a production batch and awkward in a 5 kg pilot, where the balance and the mixer struggle with a speck of powder. A dilution makes the same number of units weighable, while carrying the carrier through the whole formula and into the ingredient declaration.
Two cautions sit beside the arithmetic. The label claim has to name the basis: activity at release or activity at the end of shelf life. And the salt form changes the mass per unit, so a switch between the free base and the hydrochloride needs a new weigh-up, a new specification and a new label, not a factor applied at the balance.
How to write the grade into a specification
A specification that cannot be tested is not a specification. Seven lines make this one testable: the enzyme name and salt form; the activity with its unit definition and assay reference; the protein or specific-activity figure; loss on drying at ≤5.0%; particle size at ≥95% through 40 mesh; the source and the allergen statement; and the form, powder or granule. Add the labelled basis and the storage statement.
Write the activity as a one-sided figure (“not less than”) and keep the unit definition beside it, because a change of substrate, cell charge or assay conditions between lots makes two results incomparable even when both say U/mg. The catalog values are on the lysozyme product page; the checks that keep a diluted lot honest are on the identity page.
When a dilution or a granule is the wrong choice
If a custom dilution is on the table, three situations argue against it. A blend that is already close to its carrier limit gains nothing from more maltodextrin or glucose. A formula with a tight moisture budget gains nothing from a carrier that holds water. A label that must stay compact gains nothing from an entry that exists only to make the powder weighable.
Granulation has its own limits. A drink mix that must disperse without stirring, or a dry blend that depends on fine particles for uniformity, can lose more than it gains from a granule. There is also a process reason: every extra carrier is another material that has to be dispersion-tested, declared and held in inventory, and a dilution that solves a weighing problem at pilot scale can be the wrong grade once the batch is large enough to weigh the concentrate accurately.
The wider enzyme range follows the same logic, with different units: cellulase is chosen on CU/g and amylase on SKB/g, but in both cases the grade is an activity plus the material that carries it.
In this document
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation