What the COA for lysozyme hydrochloride actually contains
The certificate for a lysozyme hydrochloride lot reports appearance, identification, activity in U/mg, loss on drying, particle size, heavy metals and microbiology. The activity line is a kinetic measurement, so the certificate has to carry the unit definition, the Micrococcus substrate and the assay conditions next to the figure. The limits below are the catalog specification; the batch COA confirms one sealed pack of lysozyme hydrochloride powder.
An activity of 20,000 U/mg means nothing until the certificate states the unit definition, the Micrococcus substrate and the assay conditions beside it.
The certificate as a test report
A certificate can be audited only when every row answers three questions: what was measured, which method produced the number, and which release limit the lot was judged against. For the activity row there is a fourth, the conditions under which the rate was measured. A row that says “conforms” without a method and a result is a conclusion, not evidence.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White to off-white powder |
| Identification | Activity assay and IR conform | Conforms to the reference |
| Activity | Turbidimetric assay on a Micrococcus substrate, reported in U/mg | ≥20,000 U/mg |
| Loss on drying | Gravimetric | ≤5.0% |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
CAS 9001-63-2 identifies the enzyme, not the pack in front of you. A specification should therefore also name the salt form, the source and the lot, because they define the preparation that was tested. The identification row is deliberately two tests: the activity assay shows that the powder lyses the substrate, and the infrared spectrum gives a second, independent line on the protein.
What the U/mg figure measures
One lysozyme unit is defined by a rate: the amount of enzyme that produces a decrease in absorbance at 450 nm of 0.001 per minute at pH 6.24 and 25 °C in a suspension of Micrococcus lysodeikticus. A different wavelength, cell concentration or path length gives a different number for the same powder, which is why the unit definition travels with the figure rather than sitting in a footnote.
U/mg can mean per milligram of powder as sold or per milligram of protein. The catalog figure is activity per milligram of powder; specific activity, in U/mg protein, is the concentration check. Protein is read by ultraviolet absorbance with a maximum at 281 nm and a minimum at 252 nm, or by a colorimetric assay against a standard; state the method, because the two do not share a denominator.
The salt form matters to the arithmetic. The hydrochloride is the commercial form and its mass includes chloride. A 20,000 U/mg figure on the hydrochloride and a 20,000 U/mg figure on a free-base preparation do not mean the same protein mass per gram. The EU additive specification for E 1105 sets lysozyme at not less than 950 mg/g on the anhydrous basis, a protein-content gate rather than an activity gate; a certificate that reports only U/mg has not shown it.
Release limit versus batch result
≥20,000 U/mg is a floor. A result just above the floor and one far above it both pass, and the second carries more activity into a process that will consume part of it. The measured value is the useful number; the limit only says the powder passed. A result column that repeats the limit is not a result.
Ask whether the figure describes release or the end of the declared shelf life. Lysozyme is a protein and its activity falls in storage, so a certificate without that statement compares a fresh powder with an aged one. The assay's relative standard deviation matters too: close to the floor, a wide spread turns a pass into a coin toss on retest.
| Parameter | Release limit | Result column |
|---|---|---|
| Activity | ≥20,000 U/mg | A measured U/mg figure, the method and the unit definition |
| Loss on drying | ≤5.0% | A measured percentage |
| Heavy metals | Per element | A measured figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
| Particle size | ≥95% through 40 mesh | The measured percentage through the sieve |
What moves between batches
The raw material is biological, so the starting activity varies before processing begins. Extraction, clarification, salt precipitation, ultrafiltration, drying and milling each move the final figure: purification raises activity per gram, drying sets the moisture, and milling sets the mesh. Chloride moves with the salt form, not the activity, so a chloride shift can point to a different salt rather than a different enzyme.
Colour is the least quantitative line and often the most revealing. White to off-white is a wide window; a grey or brown shift can follow a hotter dry, a longer hold or a Maillard reaction with a reducing carrier while the activity still passes. Read the batch record before rejecting a lot on colour alone, and watch a trend across lots more closely than a single result near an edge.
Method drift is the quiet one. A new substrate lot, a different cell suspension, a changed path length or a re-made standard makes two U/mg results incomparable even when both certificates use the same words. The lot code on the certificate should match the pouch, the drum and the retained sample.
When to order an outside test
Order an independent test for a new source, a first shipment into a regulated market, a disputed result, or a label claim that rests on the activity figure. The panel can stay narrow: activity by the same turbidimetric method, protein, SDS-PAGE for the expected band (about 14.3 kDa for the hen egg white enzyme), chloride by ion chromatography, loss on drying, ICP-MS metals and microbiology. If the source is egg white and allergen labelling is at stake, an egg-protein ELISA adds a line.
The referee has to run the same substrate and conditions as the specification, or the comparison measures methods rather than powders. Ask for the detection limit on each screen, and require the lot code on the sample and on the report. The sample tested should be the sample retained.
What to compare between suppliers
Put six lines side by side: enzyme name and salt form; CAS number; activity result with the unit definition; protein or specific activity; loss on drying and particle size; heavy metals, microbiology and the lot trace. Two quotations can agree on 20,000 U/mg and differ on all five of the others. The same reading applies to cellulase and amylase certificates, where the unit definition carries the same weight.
The catalog specification sits on the lysozyme product page. The tests that separate a genuine lot from a diluted one are on the identity page; the laboratory vocabulary is in the analytical methods library; the release workflow behind the certificate is described on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation