01 COA & batch testing

What the COA for lumbrokinase actually contains

Technical document 01 · Reviewed 2026-11-19 · Lumbrokinase

On this page
  1. Reading the certificate line by line
  2. How the U/g result is defined
  3. Release limit versus batch result
  4. What moves between lots
  5. When an outside test is warranted
  6. What to compare between suppliers

A lumbrokinase COA earns its place when the activity result can be reproduced. The catalogue limit is ≥20,000 U/g on a fibrin plate, alongside appearance, identification, protein, moisture, metals, microbiology and particle size. A lot certificate records what was measured on one pack; it does not make the catalogue limit a batch result, and it cannot define the unit without the method.

In one line

A lumbrokinase activity figure is a lysis-zone result on a named fibrin plate, so the unit definition, the standard and the moisture basis belong beside the number.

Reading the certificate line by line

One line carries most of the commercial value, and several others decide whether the pack can be released. Activity is what the buyer is paying for; identification asks whether that activity belongs to the named preparation; moisture, metals and microbiology ask whether the powder is fit to use. A limit without a method is only half a line, because “conforms” is a conclusion and the buyer needs the measurement underneath it.

Release tests for lumbrokinase powder
TestMethodLimitWhy it is on the sheet
AppearanceVisualWhite to off-white, free-flowing powderQuick check on colour and physical form
IdentificationFibrin-plate activity and protein patternConforms to the referenceTies the activity to the preparation
ActivityFibrin plate with the standard and conditions named≥20,000 U/gThe commercial measurement
Protein contentColorimetric or KjeldahlReported, with the methodBasis for specific activity
Loss on dryingGravimetric≤5.0%Moisture basis for the as-is result
Heavy metalsICP-MSPb ≤3 mg/kg; As ≤2 mg/kg; Cd ≤1 mg/kg; Hg ≤0.1 mg/kgContaminant release
MicrobiologyPlate count plus absence testsYeast and mould ≤100 cfu/g; APC ≤1,000 cfu/g; E. coli and Salmonella absentHygiene of the lot
Particle sizeSieve analysis≥95% through 40 meshFlow and blend behaviour

Identification is the line buyers tend to over-read. A fibrin plate can respond to other proteases that digest fibrin, so the activity result describes a reaction rather than a source. The protein pattern supplies the second dimension: an SDS-PAGE gel of a lumbrokinase preparation usually shows several bands, and the pattern is compared with a reference rather than read as a purity percentage. The identity page sets out the records that separate the preparation from a blend.

How the U/g result is defined

A unit per gram measures a rate, not a concentration. In the usual plate format, fibrinogen is turned into fibrin in an agarose layer, a dilution of the powder is added to a well, the plate is incubated, and the cleared zone is measured against a standard. The plate, the fibrin source, the standard, the incubation time, the temperature and the reading rule are all part of the definition.

That is why two sheets can both show “20,000 U/g” and describe different amounts of activity. One may read the zone against a urokinase reference; another may use a house standard or a lysis-area rule. The method sheet has to say which, and the result has to be traceable to the standard used on that day.

Results are quoted against the gram of powder as sold, not against the gram of protein and not against the gram of dry solids. A powder that takes up moisture carries fewer units in each gram at unchanged dry matter, so the loss on drying belongs beside the activity. If a sheet converts to a dry basis, it should show the moisture figure used for the conversion. Protein content completes the picture: units divided by protein gives specific activity, a ratio that is more stable across lots than either number alone.

Release limit versus batch result

A limit is a gate; a result is a measurement. Both belong on the certificate, in separate columns, with the method beside them. A result column that repeats the specification range has copied the gate instead of showing that the lot passed it.

What a batch result should look like
LineGateWhat the result should show
Activity≥20,000 U/gA measured figure with plate, standard and conditions
IdentificationConformsThe activity result and the protein pattern behind it
Loss on drying≤5.0%A measured percentage
Heavy metalsPer elementOne measured value per element, in mg/kg
MicrobiologyCounts and absencePlate count plus absence confirmation
Particle size≥95% through 40 meshSieve pass, reported as a percentage

For this product the activity line is the one that can fail on its own. The contaminants are release gates, but the enzyme is the product. A certificate that gives the activity without the standard and conditions has supplied a number that cannot be reproduced or compared with another supplier's number.

What moves between lots

The raw material is earthworm tissue, so the starting point is biological rather than a fermentation tank. Species, tissue, origin and the feed or culture record shape the protein profile; extraction, purification, drying and blending shape the activity and the moisture. A final standardisation step may blend lots to a declared activity, which makes homogeneity and sampling part of the release decision.

Colour is the least quantitative line and a weak signal. White to off-white covers a range, and a slightly darker powder can still meet every chemical limit. A falling activity, a rising loss on drying, a changed protein pattern or an extra gel band are stronger signals.

The trend across lots matters more than one result near an edge. The code on the certificate has to appear on the pouch, the drum and the retention sample. Without that match, the paperwork and the goods are two separate stories.

When an outside test is warranted

Call for an independent test when the source is new, when a lot enters a regulated market for the first time, when a blend is suspected, or when a result is disputed. The useful panel is targeted rather than a full repeat: fibrin-plate activity with the method sheet, protein content, SDS-PAGE, loss on drying, the heavy-metal panel and microbiology. DNA barcoding of a retention sample can help confirm the earthworm species where the source record is thin.

Ask the laboratory to state its detection limit and recovery for each screen. A “not detected” line without a limit describes the method, not the powder. The sample tested should be the one retained, and the report should carry the lot code.

What to compare between suppliers

Six lines make a useful comparison: species and source record; activity with the plate, standard and conditions; protein content and specific activity; loss on drying; contaminants and microbiology; pack format and lot identity. Two quotations that agree on the number but differ on the standard are not offering the same material.

The certificate should name who manufactured the lot, which species and tissue were used, and which drying and milling steps produced the 40 mesh powder. The catalogue values are on the lumbrokinase product page. The assay framework is described on the analytical methods page, the release workflow is on the quality page, and the grade options are on the grades page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation