06 Identity & adulteration

How a lumbrokinase lot is proved

Technical document 06 · Reviewed 2026-11-19 · Lumbrokinase

On this page
  1. Four records, not one test
  2. Specific activity and the substrate ratio
  3. X-ray diffraction and the solid state
  4. What substitution looks like
  5. Writing identity into the specification
  6. Five questions for the supplier

Lumbrokinase is a mixture, so no single band, peak or activity number identifies it. A lot is accepted when four records line up: the earthworm species and tissue, the protein pattern, the fibrin-plate result and the trail from pack to certificate. Each record answers a different question.

In one line

A lumbrokinase lot is proved when the source record, the protein pattern, the fibrin-plate activity and the lot trace agree, not by a single activity figure.

Four records, not one test

Paperwork can name the right material without proving that the powder in the drum is that material. The four records below are separate questions, and a supplier who answers only the first has described a label, not a lot.

The four identity records for lumbrokinase
RecordQuestion it answersEvidenceWhat it establishes
OriginWhich earthworm, which tissue?Species and tissue declaration; DNA barcode where neededThe biological source
ProteinDoes the band pattern match the reference?SDS-PAGE against a reference preparationThe protein mixture, not one enzyme
ActivityDoes it digest fibrin as declared?Fibrin plate with the standard and conditions namedA rate under those conditions
TraceIs this the pack that was tested?Lot code on pack, certificate and retention sampleThe link between result and goods

Each record is weak on its own. Origin without activity describes an extract; activity without a protein pattern describes a reaction; a certificate without a lot code describes no particular container. The combination is what makes the identity file auditable.

Specific activity and the substrate ratio

Activity divided by protein gives specific activity, normally written as U per milligram of protein. For a fixed grade that figure should stay in a narrow band from lot to lot. If activity holds while the ratio falls, the protein load has grown without a matching gain in units: a carrier, a different cut during recovery, or a fraction that has lost activity. If the ratio rises, either the protein measurement is low or the activity standard has moved.

Two ratios and the questions they open
RatioCalculationWhat a shift suggests
Specific activityU/g divided by protein contentA dilution, a recovery change or an inactive fraction
Substrate ratioFibrin-plate activity compared with a broad protease assayA blend or a non-fibrin protease used to lift the plate result

The substrate ratio is a screening comparison, not a fixed official constant. It becomes useful when the same two methods are applied to every lot and to the reference, so that a movement can be seen. If both individual results stay in range but the ratio moves, the protein pattern is the next test to run.

Protein methods carry their own bias. Colorimetric assays respond differently to different proteins, and Kjeldahl measures nitrogen rather than protein. The ratio is comparable only when the protein method is held constant, and a certificate that reports protein without naming the method has given a figure that cannot enter the ratio.

X-ray diffraction and the solid state

X-ray diffraction describes the solid, not the enzyme. A protein preparation is largely amorphous, so an XRD pattern will not identify lumbrokinase in the way it identifies a crystalline mineral salt. What the method can show is whether a crystalline phase is present: a crystalline carrier, an inorganic diluent or a salt from standardisation can produce sharp reflections where the protein produces none.

That makes XRD a check on the carrier and a poor identity test. A certificate that says “XRD conforms” without a reference pattern and a detection limit has said very little. Where the solid form is disputed, ask for the pattern, the reference and the interpretation, then read it alongside the protein pattern and the activity result. XRD is not a routine release test here.

What substitution looks like

Substitution routes and the checks that reveal them
RouteWhat can passSignalCheck
Dilution with carrierA declared U/g if the blend is assayedHeavier dose weight; specific activity flat or lowerCarrier declaration, mass balance, protein
Another proteaseFibrin-plate activityDifferent band pattern; substrate ratio shiftsSDS-PAGE, comparison of substrates
Inactive powderProtein contentActivity low; specific activity fallsFibrin plate with protein
Wrong earthworm speciesActivity and appearanceSource record gap; protein pattern differsDNA barcoding, source audit
Overstated activityA certificate figureIndependent result lowerReferee assay by the named method
Mislabelled lotA certificate from another batchCode mismatchPack, certificate and retention sample

These are checks, not allegations. A buyer who stops at the activity result has used one of the four records. Colour is the weakest signal of all: white to off-white covers a wide range, and another powder can match it. The protein pattern, the specific activity and the source record are harder to imitate.

Writing identity into the specification

  • “Lumbrokinase preparation from earthworm; species, tissue and origin stated in the source record.”
  • “Activity ≥20,000 U/g by the fibrin-plate method, with plate, standard, incubation and reading rule on the COA.”
  • “Protein content with the method named; specific activity calculated and reported.”
  • “SDS-PAGE pattern consistent with the reference; report the bands, not only a pass statement.”
  • “Carrier and any additional enzyme activity declared; no undeclared diluent.”
  • “Loss on drying ≤5.0%; particle size ≥95% through 40 mesh; metals and microbiology within the listed limits.”
  • “Lot code repeated on the pack, the certificate and the retention sample.”

Five questions for the supplier

  1. Which earthworm species and tissue were used for this lot, and where did the raw material come from?
  2. What plate, standard and conditions produced the U/g result?
  3. What is the protein content, by which method, and what specific activity follows from it?
  4. Can you send the SDS-PAGE pattern and the reference it was compared with?
  5. If the result is disputed, will you join a re-test on the retention sample?

Written answers to those five questions make an identity file. One activity percentage does not. The product hub lists the catalogue values. The COA page explains where each result appears on the certificate; the grades page compares the physical options; the nattokinase comparison explains why the units differ; the methods page covers the assay framework and the quality page describes the release file.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation