06 Identity & adulteration

How we prove a lactase lot has the declared activity

Technical document 06 · Reviewed 2026-11-19 · Lactase

On this page
  1. Four kinds of evidence
  2. Running the assay, not a lookalike
  3. A rate, with limits
  4. Units per milligram of protein
  5. Why diffraction and infrared fall short
  6. Five ways a lot misrepresents itself
  7. A specification that can be tested
  8. The five questions

Identity for a lactase lot rests on four kinds of evidence: the production organism and strain, the ALU assay run on the lot, the protein figure that puts activity in proportion to the protein present, and the physical constants on the certificate. The lot code is what ties all four to the pack. No single test proves identity on its own, and a certificate that offers only the activity figure has proved a rate, not a material.

In one line

A lot is identified by its organism, its assay and its protein together, and by the lot code that links all three to the pack.

Four kinds of evidence

What each layer of identity can and cannot establish
LayerEvidenceWhat it leaves open
SourceOrganism and strain, culture collection numberWhether the powder in the pack came from that strain
ActivityALU/g by the stated methodWhether the activity belongs to lactase or to another galactosidase
ProteinProtein content and ALU per milligram of proteinWhether the protein is the expected one, unless a pattern is run
PhysicalAppearance, pH, loss on drying, meshAlmost everything chemical; these are consistency checks

The layers are complementary rather than ranked. A strain statement is a statement about a process, not about a drum; an activity figure can be met by a different enzyme; and colour, pH and mesh describe the preparation without naming it. Put together, and tied to a lot code, they are hard to satisfy with the wrong material.

Running the assay, not a lookalike

The assay is the acid-lactase method: a dilution of the powder is added to o-nitrophenyl-β-D-galactopyranoside in buffer at pH 4.5 and 37 °C, the reaction is stopped after a fixed time, and the yellow o-nitrophenol released is read against a standard curve. The calculation converts absorbance to micromoles, divides by time and by the enzyme charge, and reports ALU per gram of powder as sold.

Every one of those steps is a place where two laboratories can diverge: the dilution into the linear range, the substrate concentration, the blank, the stop reagent, the wavelength, the standard. A buyer verifying a lot should run the supplier's written method, not a method with the same name. Assay is a procedure before it is a number, and the certificate should cite the procedure it used.

A "lactase assay" run on lactose with glucose detection is a different measurement. It uses the natural substrate and reads product formation indirectly, so its figures do not compare with ALU on ONPG.

A rate, with limits

An ALU is a rate. It says how fast the preparation liberates o-nitrophenol under one set of conditions, and it says nothing about purity, protein content or how the powder will behave in a blend. The specification is one-sided at ≥100,000 ALU/g, so a lot can be far above the floor and still be described by the same figure.

It is also not a universal lactase unit. The ALU versus FCC LU page explains why a number in one unit has to be re-measured rather than recalculated, and the COA page shows where the unit definition sits on the certificate.

Units per milligram of protein

Protein is measured colorimetrically against a standard, or by nitrogen determination with a conversion factor that may not suit this preparation. Neither is a purity assay, and both are sensitive to the carrier: maltodextrin contributes mass but almost no protein, so a dilution lowers ALU per gram and protein per gram together.

That is what makes the ratio useful. ALU per milligram of protein stays roughly constant when a powder is diluted with carrier, because both numerator and denominator fall together. It moves when the material changes in kind: a different fermentation, a different recovery, or an added enzyme with a different specific activity.

Reading per-gram activity against the protein ratio
ObservationConsistent with
Low ALU/g, ratio unchangedDilution with carrier; check the carrier declaration
Normal ALU/g, ratio highA more active concentrate, or an added enzyme
Normal ALU/g, ratio lowExtra non-enzyme protein, or a protein filler
Low ALU/g, ratio lowInactivation, or a different preparation

Why diffraction and infrared fall short

Buyers who are used to mineral specifications ask for an X-ray diffraction pattern or an infrared spectrum. Neither answers the question here. An enzyme powder is amorphous, so X-ray diffraction returns a broad halo from the carrier rather than a fingerprint of the protein, and an infrared spectrum of a standardised powder is dominated by the carrier and by residual water.

Those methods still have a place: diffraction confirms that the carrier is amorphous, and infrared is a quick check on a pure crystalline excipient. For the enzyme itself, the pattern that carries information is a protein gel, where bands separate by molecular weight and an unexpected band is visible.

Five ways a lot misrepresents itself

Failure modes and the test that exposes each
Failure modeWhat it looks likeTest that exposes it
DilutionActivity per gram below declarationAssay, plus protein and the carrier declaration
SubstitutionActivity passes, protein pattern does notGel electrophoresis against a reference
Blending active with spent powderActivity passes at the average; ratio driftsAssay, protein and pattern together
InactivationLow activity with normal proteinAssay against protein; storage history
False activityColour at the read wavelength without enzymeBlank and a zero-time control

The pattern is the test most often skipped and most often decisive. A lot that passes the assay but shows extra bands need not be fraudulent — a blend of two preparations looks the same — but it is not the single preparation the certificate describes.

A specification that can be tested

A checkable specification names the activity and the unit, cites the method, states the substrate, pH, temperature and time, and fixes the basis at release or at end of shelf life. It adds protein or specific activity, loss on drying, mesh and appearance, and it requires the certificate to carry the organism and strain and the lot code. Two lines that are usually missing are the carrier's identity and the method's repeatability; both decide whether a result near the limit means anything.

The five questions

Which strain, by designation and culture collection number? Which method, with substrate, pH, temperature and time written out? What is the measured activity of this lot, and what is the protein figure? What does the protein pattern look like against your reference, and can I see it? And which lot code appears on the pack, the certificate and the retained sample?

The answers belong in the file beside the certificate. Catalog figures are listed on the lactase product page; the release sequence is described on the quality page; and the dilution arithmetic is worked on the grades page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation