ALU vs FCC LU: what a lactase unit actually means
ALU and FCC LU both come from the same chromogenic chemistry: an enzyme sample is mixed with o-nitrophenyl-β-D-galactopyranoside, the galactoside bond is cut, and the o-nitrophenol released is read as colour. The difference is in the assay each name points to. ALU names the acid-lactase method at pH 4.5 and 37 °C; "FCC LU" points at a monograph family that contains more than one lactase method, so it does not identify a single set of conditions by itself.
A lactase unit is the assay that defines it, so ALU and FCC LU compare only when the method, the substrate and the pH are written beside the number.
Two labels, several procedures
An enzyme unit is a rate expressed in a defined assay. Change the substrate, the pH, the temperature or the time, and the same powder produces a different number under a name that may look the same. That is why a unit abbreviation is not a quantity: it is the short label of a procedure, and the procedure has to travel with it.
Both abbreviations in this comparison describe β-galactosidase activity on a chromogenic substrate. Neither describes protein content, purity, or how much activity survives a process step. Those are separate measurements, covered on the COA page.
The acid-lactase definition
One acid lactase unit is the quantity of enzyme that liberates one micromole of o-nitrophenol per minute from ONPG at pH 4.5 and 37 °C, with the reaction stopped after a fixed incubation, usually fifteen minutes, and the colour read against a micromolar o-nitrophenol standard. The result is reported per gram of preparation as sold.
The strength of the definition is that it is narrow. ALU is the unit normally used for acid lactase from Aspergillus oryzae, the material specified here, so a figure in ALU/g on a supplier's certificate has a good chance of being comparable with another supplier's figure. The weakness is that pH 4.5 and ONPG are chosen for the assay, not for the application: a blend at a different pH, or a process at a different temperature, will not see the activity the assay saw.
The Codex family
FCC LU is the Food Chemicals Codex's lactase unit, defined in a monograph. The Codex carries more than one lactase monograph: the acid lactase method works on ONPG at pH 4.5 and 37 °C and defines the acid lactase unit, while the neutral lactase method works near pH 6.5 and reports a neutral lactase unit on a different scale. A certificate that says "FCC LU" without naming the monograph has not said which of these it means.
| Aspect | ALU | FCC LU |
|---|---|---|
| Where the definition sits | Acid-lactase assay, widely used for A. oryzae lactase | A monograph in the Food Chemicals Codex; acid and neutral monographs differ |
| Substrate | ONPG | ONPG in both monographs |
| pH | 4.5 | 4.5 for acid lactase; near 6.5 for neutral lactase |
| Temperature | 37 °C | 37 °C in the current acid method |
| Time and readout | Fixed incubation, o-nitrophenol colour | Set by the monograph and its edition |
| Typical material | Acid lactase powders for supplement blends | Either acid or neutral lactase, depending on the monograph cited |
The table also hides a smaller variable: editions of the Codex revise methods. A method reference that gives the edition is more useful than a unit name, because it pins the conditions the laboratory actually followed.
No factor, only a measurement
A conversion factor would be a claim that the ratio between two assays is constant across preparations. It is not. Where both methods use ONPG at pH 4.5 and 37 °C, the two figures should be close, and a supplier may use the names as if they were interchangeable; that is a claim to verify, not a rule. Where one method runs near pH 6.5, the enzyme is measured away from the other method's pH, and which figure comes out larger depends on where the preparation's own pH optimum sits.
Substrate adds a second variable. An assay on lactose measures hydrolysis of the natural substrate and detects the glucose or galactose released; it is a legitimate measurement, and it is not the same measurement as ONPG. Product inhibition, substrate concentration and detection chemistry all move the result.
What does convert is the total unit count. One kilogram at 100,000 ALU/g carries one hundred million ALU; two kilograms at 50,000 ALU/g carry the same total. That arithmetic is exact and useful for blend calculations. It says nothing about the ALU-to-FCC-LU relationship, which only a paired measurement on the same sample can settle, reported with the lot number.
Writing the unit into documents
Where the buyer is a manufacturer and not a consumer, the label must state the activity and its unit, with the name, the food-use statement, the lot and the storage conditions (Regulation (EC) No 1332/2008). The unit in that statement has to be defined somewhere the buyer can read it, and the specification is the natural place. A declaration of "100,000 LU/g" with no method reference is an incomplete label, whichever Codex edition it came from.
In the United States the figure is a specification rather than a nutrient: no nutrition panel, no Daily Value. Where the enzyme functions in the finished food, the ingredient list names it; the activity stays in the specification and on the certificate. In Great Britain the assimilated regulation applies in the same shape as the EU rule. On all three markets, the practical requirement is the same: name the unit, cite the method, and state whether the figure is guaranteed at release or at the end of shelf life.
Choosing the unit for a purchase order
For an acid lactase powder dosed into a supplement blend, ALU/g on ONPG is the practical choice. The method is quick, the definition is narrow, and the figure can be checked at goods-in by any laboratory set up for the assay. Specify FCC LU only when the customer's finished-product specification is already written in FCC units, and then name the monograph and the edition so both sides are measuring the same thing.
Where a buyer needs both, ask for both figures on the same lot rather than a conversion from a catalogue. A measured pair is data; a factor is a guess with a decimal point. Grade options are compared on the grades page; the identity evidence sits on the identity page; terms are defined in the assay glossary entry; and the catalog figures are on the lactase product page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation