02 Grade comparison

100,000 ALU/g or a dilution: choosing a lactase grade

Technical document 02 · Reviewed 2026-11-19 · Lactase

On this page
  1. A grade is a concentration, not a purity
  2. Four options and their arithmetic
  3. Mesh, flow and airborne dust
  4. Working back from the blend
  5. What a grade description must contain
  6. Where a dilution costs more than it saves

Three decisions make a lactase grade: how much activity sits in a gram, what carrier was used to get there, and what the particles look like. A 100,000 ALU/g preparation and a 25,000 ALU/g dilution can put the same number of ALU into a batch, but they change how much powder is weighed, how much carrier enters the formula and how the blend behaves on a filling line. The catalog grade is ≥100,000 ALU/g at 40 mesh; lower-activity dilutions and a granulated form are made to order.

In one line

Choosing a lactase grade is choosing how many ALU arrive in each gram of the blend, and which carrier arrives with them.

A grade is a concentration, not a purity

An enzyme preparation is not sold as a percentage. The active substance is a protein in a fermented broth, and the powder around it is there to carry, protect and standardise that protein. A grade is therefore a concentration: how many ALU the supplier guarantees in each gram of the material as sold.

Concentration is set at the end of the process, not the beginning. The fermentation and the recovery produce a concentrate of whatever strength the run delivers, and the concentrate is then blended with a carrier — usually maltodextrin for a food enzyme — until the target activity is reached. Two packs at 25,000 and 100,000 ALU/g can come from the same concentrate; the difference is how much carrier was added. That is why the carrier belongs in the grade description and not only in the specification footnotes.

Four options and their arithmetic

Grade options and what each one changes in a formula
GradePowder to weigh for 1,000,000 ALUCarrier in that massWhere it fits
100,000 ALU/g powder, 40 mesh10 gLow share of the massConcentrated blends, small stick doses
50,000 ALU/g20 gAbout half the massBlends where 10 g is hard to distribute
25,000 ALU/g dilution40 gAbout three quartersLow-activity blends, better weighing accuracy
Granulated, 100,000 ALU/g10 gLow share, plus binderDust-controlled rooms, free-flowing lines

The arithmetic is linear and exact: halving the activity doubles the mass for the same unit count. What is not linear is everything the extra mass brings — carrier solids in the stick, a larger fill volume, more powder to move through the room, and a bigger share of the label's ingredient list.

Mesh, flow and airborne dust

The catalog powder is sieved so that ≥95% passes 40 mesh: free-flowing, not a flour. Mesh matters for two reasons: it sets how the powder behaves in a ribbon blender or a loss-in-weight feeder, and it sets how much dust becomes airborne when an operator opens the pack. Enzyme powders are respiratory sensitisers, so the dust question is a control question, and a coarser granule is one answer to it.

Granulation is not free. A granulated grade is built by agglomerating the powder with a binder and drying it, and that wet step is exactly the kind of process that costs activity. A granulated 100,000 ALU/g grade therefore starts from a stronger concentrate than a plain powder of the same declared activity, and the certificate should confirm the activity after granulation rather than before it.

Colour is a weak signal. The colour range runs white to light brown; a darker shade can result from a hotter dry or a longer hold, with the assay still passing. Judge flow from the particle size and mesh data, and check the batch record before rejecting on colour.

Working back from the blend

Start from the activity the finished blend must carry per gram or per unit, then divide. If a blend is specified at 1,000 ALU/g, one gram of the 100,000 ALU/g powder goes into 100 g of blend. The same blend built from the 25,000 ALU/g dilution needs four grams of powder for the same 100 g. Both are correct: the dilution is easier to weigh at small batch size, and the concentrated grade keeps the stick fill weight down.

Weighing accuracy is the hidden variable. A 2 g batch addition on a balance that reads to 0.01 g carries a 0.5% error; the same absolute error on a 0.2 g addition is 5%. Where the dose per unit is small, the dilution buys accuracy at the cost of mass. Where the stick fill weight is already tight, the concentrated grade buys space at the cost of weighing precision.

Then add the process margin. Activity is lost in a wet or hot step, so the blend is usually dosed above the label figure. The overage is easier to control with the concentrated grade, because the same absolute loss removes a smaller share of a larger number.

What a grade description must contain

A grade description that can be checked names the activity, the unit, the carrier and the form. "Lactase, ≥100,000 ALU/g, 40 mesh, maltodextrin carrier" is a grade; "lactase powder" is a category. Then add the method by reference, the moisture limit, the sieve fraction and the basis of the figure, whether at release or at end of shelf life.

Two lines are worth adding for blends: the activity after the process step the buyer will run, and the carrier's allergen and GMO status. The first is measured on a trial blend, not assumed from the raw powder; the second is a document, not a number. The COA page shows where those lines sit on the certificate.

Where a dilution costs more than it saves

A dilution is the wrong grade when the carrier load breaks the formula: a capsule or a small sachet has a fill weight it cannot exceed, and four times the powder may not fit. It is also wrong when the analytical method cannot read the diluted blend — if the finished-product assay's limit of quantification sits near the expected activity, a 25,000 ALU/g material leaves little signal above the noise.

It is the wrong choice when the room is the problem rather than the scale. If dust is the reason for looking at a dilution, a granulated grade of the same activity solves the dust without changing the mass. And it is wrong when the extra mass has to be shipped and stored: carrier is weight, and weight is freight, warehouse space and disposal.

The unit itself is the last check. If the buyer's specification is written in FCC lactase units rather than ALU, the grade comparison is not a dilution question until the units are reconciled, which is the subject of the ALU versus FCC LU page. Processing losses are set out on the stability page, and the catalog figures are on the lactase product page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation