01 COA & batch testing

Reading a chymotrypsin COA: the ATEE unit and the trypsin limit

Technical document 01 · Reviewed 2026-11-19 · Chymotrypsin

On this page
  1. What each row has to establish
  2. The unit, the substrate and the dried basis
  3. Where the release limit ends and the result begins
  4. Why two lots at 1,000 U/mg differ
  5. When an outside assay is worth it
  6. What to compare between suppliers

A lot certificate for chymotrypsin has to show what the powder is, how active it is and how clean it is: appearance and identity, ATEE activity in USP units per milligram, the trypsin result, moisture, metals, microbiology and mesh. Activity is a rate, not a mass, so the figure needs its substrate, wavelength, pH, temperature and basis to mean anything. The limits below belong to the catalog specification; the certificate for a lot is what confirms the pack that ships.

In one line

A chymotrypsin figure is a rate measured on ATEE at 237 nm, so the unit definition, the assay conditions and the dried basis have to be read with the number.

What each row has to establish

A certificate earns its place when every line can be checked: what was measured, by which method, against which limit. A row that reads “conforms” without a result asks the reader to trust a conclusion.

Release limits for the catalog grade (≥1,000 USP U/mg)
ParameterRelease limitMethod
AppearanceWhite to off-white powderVisual check
IdentificationConforms to the referenceATEE assay plus infrared spectrum
Activity≥1,000 USP U/mgATEE, 237 nm, pH 7.0, 25 °C; basis stated
TrypsinRatio limit agreed; result in trypsin unitsBAEE, 253 nm, pH 7.6, 25 °C
Loss on drying≤5.0%Gravimetric
Heavy metalsPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kgICP-MS
MicrobiologyAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absentPlate count plus absence tests
Particle size≥95% through 40 meshSieve analysis

The trypsin result is the clearest sign of how far purification went. Chymotrypsin and trypsin are recovered from the same gland and tend to travel together, so a chymotrypsin lot contains some trypsin unless a separation step took it out. The specification should cap that companion activity as a ratio, and the certificate should report it in trypsin units from the same lot.

The unit, the substrate and the dried basis

Two conventions decide whether the activity number can be compared. The first is the unit. One USP chymotrypsin unit is the activity that causes a change in absorbance of 0.0075 per minute at 237 nm, with ATEE as the substrate, at pH 7.0 and 25 °C. That is a rate, not a weight, so a purer milligram produces a larger change and carries more units.

The second is the basis. The USP monograph sets not less than 1,000 USP chymotrypsin units per milligram calculated on the dried basis, and it sets the labeled potency at 90.0 to 110.0 per cent. A result on the dried basis is higher than the same powder measured as-is, because the calculation divides by the dry matter; at the 5.0% loss-on-drying limit the gap is about five per cent. The certificate should carry the basis in the assay row rather than a footnote.

Quotations can carry a different unit under the same word. The table sorts the four figures a buyer may see.

Four figures that may be called chymotrypsin activity
FigureWhat it measuresWhat it can be compared with
USP U/mgA237 changing 0.0075/min with ATEE, pH 7.0, 25 °CAnother result from the same method and basis
BTEE U/mgA256 with BTEE as the substrateOnly another BTEE result; not a USP figure
U/mg proteinActivity divided by the protein contentHow pure the preparation is, not how strong it is per gram
Units per gram of blendActivity of a diluted or blended powderThe blend's own certificate, not the concentrate

The BTEE substrate and wavelength differ, so no factor converts one figure into the other.

Where the release limit ends and the result begins

The catalog limit is one-sided: at least 1,000 USP U/mg. A lot at 1,005 and a lot at 1,600 both pass, but the first has less margin for the loss between release and use. The labeled-potency window of 90.0 to 110.0 per cent is a second gate that a single activity figure does not cover.

What the result column should contain
ParameterRelease limitResult column
Activity≥1,000 USP U/mgA measured figure, the basis, the method and the release date
TrypsinRatio limitA measured figure in trypsin units on the same lot
Loss on drying≤5.0%A measured percentage
Heavy metalsPer elementA figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot

“Passes specification” is a conclusion, and the reader should be able to reach it from the numbers. Microbiology is evidenced by a count and an absence statement; heavy metals need a figure for each element, because a combined total hides which metal is present.

Why two lots at 1,000 U/mg differ

The gland is a biological raw material, and the species, the age of the animal and the season shift the starting mixture. How the zymogen is activated, how the separation is run, how salt is removed and how the powder is dried all determine the activity that survives into the pack. Self-digestion is the particular hazard: a warm or alkaline hold can consume the very enzyme being made, and the result is a low activity figure with no visible defect.

Milling and sieving add a change unrelated to the enzyme. The 40 mesh line is a finishing specification, so it moves when the mill or the sieve moves. Colour says little. White to off-white is a broad window, and a darker shade may simply reflect a different drying route while the activity is unchanged.

The trypsin ratio is the figure most likely to differ between suppliers, because it reflects the depth of the separation rather than the drying step. Check that one lot code appears on the certificate, the pouch or drum, and the retained sample.

When an outside assay is worth it

Commission an outside test when a source is new, when a lot is the first into a regulated market, when a result is disputed, or when a blend's label rests on both enzymes. The laboratory should run the specification method rather than improvise: ATEE activity at 237 nm, protein and specific activity, a gel pattern, the trypsin assay, moisture, ICP-MS metals and a micro count.

An outside result is comparable only when the method matches: a different substrate, wavelength, pH or temperature describes a different assay. Ask for the raw rate, the weighed enzyme mass and the arithmetic, and supply the referee with both the retained sample and the specification.

What to compare between suppliers

Set six items side by side: source and species; unit definition and method; measured activity and its basis; trypsin ratio; protein and specific activity; moisture, mesh and pack. Two offers can print the same 1,000 USP U/mg and still describe different materials if the other five lines diverge.

The catalog entry sits on the chymotrypsin product page; the grades page sets out activity and form, the identity page shows the supporting analyses, the methods section explains the assay terms, and the quality page describes how release is handled.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation