GDU vs FIP: what a bromelain unit actually means
GDU and FIP are both units of bromelain activity, and neither is a mass. The GDU is defined on gelatin, the FIP unit on casein, and the two assays use different substrates, conditions and readouts. A supplier can quote one, the customer's specification can require the other, and the number in between is an estimate unless the same laboratory measured both.
GDU and FIP are both rates measured on a substrate, not masses, so a figure converts only with the method that produced it.
A unit is a rate, not a mass
Enzyme activity is a rate: how much substrate is converted per unit time under stated conditions. The unit therefore carries the substrate, the pH, the temperature and the readout inside its definition. “2,400 GDU/g” is a concentration of activity, not a weight of enzyme, and “2,400 GDU” on its own does not say per gram, per capsule or per serving.
The same logic applies to the prefix. 2.4 FIP U/mg is 2,400 FIP/g; a certificate that mixes the two conventions can look a thousand times stronger or weaker than it is. Read the unit and the denominator before comparing any two numbers.
GDU: gelatin and amino nitrogen
GDU stands for gelatin digesting unit. The common definition is the amount of enzyme that liberates 1 mg of amino nitrogen from gelatin in 20 minutes at 45 °C and pH 4.5. The readout is amino nitrogen, not a coloured tyrosine equivalent, and the substrate is gelatin, a protein with a characteristic amino acid balance. The assay is widely used for bromelain because it is robust and because the 1,200 and 2,400 GDU/g grades are traded in it.
It is also a method family rather than a single locked procedure. Method sheets in circulation use pH 4.5 or 5.5, different gelatin sources and different ways of stopping the reaction. That is why a certificate should name the method, and why two GDU figures from different laboratories are not necessarily the same measurement.
FIP: casein and tyrosine
FIP stands for Fédération Internationale Pharmaceutique. The FIP protease unit is defined on casein: the substrate is hydrolysed at 35 °C, the reaction is stopped with trichloroacetic acid, and the acid-soluble tyrosine is measured. One FIP unit corresponds to 1 µmol of tyrosine per minute, and 1 FIP unit equals 1 Ph. Eur. unit. The method sheet for bromelain fixes the pH, so ask for it rather than assuming the general protease conditions.
The substrate, the pH, the temperature and the readout are all different from the GDU assay, so the two units describe the same kind of activity through different lenses. FIP units appear in pharmacopoeial and European product documentation, and some customers specify them for that reason.
The FIP unit is not a universal currency either. It is defined per enzyme and per method, and a FIP figure on a bromelain certificate should be backed by the casein method, not by arithmetic from a GDU result.
Why a conversion factor is not a specification
Suppliers often quote a trade factor of about two FIP units per GDU, which would put 2,400 GDU/g near 4,800 FIP/g. The factor is empirical: it depends on the two methods, the substrate batches, the standard and the preparation, and it can shift between lots and laboratories. Used as a rough cross-check it is useful; used to write a specification it is a guess dressed as a number.
The safer route is to measure both on the same lot, or to buy against the unit the customer's specification names and ask for the method behind it. If a certificate shows a FIP figure that was calculated from GDU/g, the certificate should say so. A calculated figure presented as a measured one is a common unit error in this ingredient.
What the label and the file must say
No market prescribes GDU or FIP as the only permitted unit, but the label must not mislead. State the unit and the denominator — “2,400 GDU/g” or “240 GDU per capsule” — and keep the arithmetic consistent with the mass declared. A label that says “Bromelain 2,400 GDU” without a denominator is ambiguous, and a label that declares 500 mg of a 2,400 GDU/g powder is declaring 1,200 GDU, not 2,400.
In the US the Supplement Facts panel declares the amount per serving, and the unit should be the one the certificate states. In the EU and the UK the ingredient list and the quantitative declaration follow the general food information rules, and any activity statement must be truthful and substantiated. The compliance file should carry the certificate that matches the label unit, not a converted figure.
Choosing a unit for a purchase
Choose the unit the finished-product specification or the customer's reference product uses, and make the certificate match it. If the specification is written in GDU, buy GDU and do not accept a FIP figure converted at the supplier's factor. If it is written in FIP, ask for the casein method and a measured result. If both are needed, assay both on the same lot and keep the raw data.
The unit is also a contract term. Write it into the purchase order with the method and the basis, and agree which laboratory is the referee before the first shipment. The grades page covers the activity levels; the COA page shows where the unit sits on the certificate; the identity page covers the protein evidence behind the number. The product page carries the catalog grade, and the compliance page covers the label rules.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation