What the COA for beta-glucanase actually contains
The certificate for a beta-glucanase lot reports appearance, activity in U/g on a glucan substrate, identification by the activity assay, loss on drying, particle size, the heavy-metal panel and microbiology. The activity row describes the enzyme, and it means little unless the certificate sets the unit definition, the substrate, the assay pH and the temperature beside it. The values below are the catalog specification; the batch COA confirms a particular pack.
A beta-glucanase figure is a rate on a named glucan substrate, so the certificate has to carry the unit definition, the substrate and the assay conditions beside the U/g.
Reading the certificate line by line
A certificate can be audited line by line only when each row carries what was measured, the method and the release limit. For an enzyme the activity row needs a fourth element, the assay conditions, because the same powder reads differently when the substrate or pH changes.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Off-white to light tan, free-flowing powder |
| Beta-glucanase activity | Reducing-sugar assay on a beta-glucan substrate, U/g | ≥50,000 U/g |
| Identification | Activity assay | Conforms |
| Loss on drying | Gravimetric | ≤8.0% |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
| Heavy metals | ICP-MS or AAS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count; absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
The catalog identification line is the activity assay, not a spectrum. That is normal for an enzyme: a rate can come from the named enzyme, another glucanase, or reducing sugar already in the powder.
What the U/g figure measures
A unit of beta-glucanase is a rate, not a weight. The method defines it: one unit is the amount of enzyme that releases a set quantity of reducing sugar, usually one micromole of glucose equivalents per minute, from a named beta-glucan under a stated pH and temperature. Published feed-enzyme methods have used barley beta-glucan at pH 5.0 and 30 °C; house methods in the food trade may run at 40 °C or 50 °C. The certificate has to say which one it followed.
The substrate decides what is counted. Barley beta-glucan is a mixed-linkage chain with both 1,3 and 1,4 bonds. Carboxymethyl cellulose is a different substrate with a different linkage pattern, so a CU/g figure from a cellulase assay is not a beta-glucanase result. A preparation can carry side activity on both substrates, and the declared unit captures only the assay performed.
| Field | Required detail | What shifts the number |
|---|---|---|
| Substrate | The beta-glucan used, such as barley beta-glucan or lichenin | Linkage pattern and solubility change the rate |
| Unit | U per gram of powder as sold | A protein basis gives a different number |
| pH | The buffer pH of the assay | Activity is pH-dependent |
| Temperature | The incubation temperature | Rate rises with heat until the protein unfolds |
| Detection | Reducing sugar by DNS or another stated method | Different end points give different scales |
The figure is per gram of powder as sold, not on a dry basis: moisture dilutes the preparation and the U/g falls with it. A dry-solids correction is a blend calculation, not a second assay basis.
The limit and the measured result
Activity is a one-sided limit. A lot at 52,000 U/g and one at 78,000 U/g both pass ≥50,000 U/g, and the result tells a formulator how much headroom the powder carries into a process that will consume part of it.
The result column should hold a measured figure, the method reference and the release date. A result column that repeats the range is not a measurement, and "conforms" should be a conclusion the reader can draw from the figures.
Activity also falls in storage, so the certificate should state the storage condition assumed and the activity guaranteed at the end of the declared shelf life. A drum received six months after release is bought at the lower figure. The stability page sets out how the pack and the process change that number.
What varies from lot to lot
Fermentation sets the starting point: the production strain, the medium and the harvest shift the balance of enzymes in the broth. Recovery and concentration decide how much of that balance reaches the powder, and standardisation with a carrier sets the final activity per gram. Lot-to-lot spread is therefore a process decision as much as a biological one.
Drying and milling move the moisture, the colour and the particle size. The 80 mesh specification is fine enough that the powder wets quickly and also fine enough to pick up water from the air; a wetter powder reads lower per gram at constant enzyme protein, and a milling step that generates heat can destroy activity before the sieve is reached. Colour is the vaguest line on the sheet and sometimes the most informative: a darker tan can follow a hotter dry while the assay still passes.
Watch the method as closely as the number: a change of substrate lot, buffer, pH or incubation time makes two U/g results incomparable, even when both pass the same limit.
When to send a sample out
An independent test is worth ordering for a new source, a first regulated shipment, a specification that rests on the activity figure, or a dispute. The panel is narrow: activity by the buyer's own method on a retained sample, protein, loss on drying, heavy metals by ICP-MS, microbiology and a protein pattern by gel electrophoresis.
Add one assay that the certificate does not carry: activity on carboxymethyl cellulose, run beside the beta-glucan assay. The pair shows whether the preparation behaves like a beta-glucanase or like a cellulase with side activity. Ask the referee to run the same substrate, pH and temperature as the specification, or the comparison measures methods rather than powder. Ask for the detection limit on each metal; a "not detected" line without a limit describes the method, not the sample.
Keep the sample tested and the retained sample on the same lot code; a contested result needs a test that separates the preparations, not a repeat of the same assay.
How to compare two suppliers
Compare six lines: enzyme name, EC and CAS numbers; the unit definition with substrate, pH and temperature; the activity result and its basis; protein and specific activity; loss on drying and particle size; and the source strain, carrier and lot code. If two offers match on 50,000 U/g but not on the other five, they are different preparations.
Traceability is the second layer: the certificate should name the manufacturer, the organism and strain, and the carrier and mesh. The catalog specification sits on the beta-glucanase product page; the tests that separate a genuine lot from a diluted or substituted one are on the identity page; the unit definitions are compared on the beta-glucanase vs cellulase page; the assay vocabulary is in the assay glossary entry; and the release sequence is described on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.