02 Grade comparison

One activity, one mesh: choosing a beta-glucanase grade

Technical document 02 · Reviewed 2026-11-20 · Beta-Glucanase

On this page
  1. Why an enzyme grade is not a purity grade
  2. The catalog forms side by side
  3. 80 mesh, dust and dissolution
  4. The arithmetic behind the dose
  5. Writing the grade specification
  6. When the granule or the finer mesh is the wrong choice

The catalog beta-glucanase is an 80 mesh powder at ≥50,000 U/g, with a granulated form on request. The range does not carry a ladder of standard activities, so the grade question is which assay defines the unit, whether the declared figure is the release value or the end-of-shelf-life value, and whether the powder or the granule fits the plant. The activity number alone does not answer it.

In one line

Choosing a beta-glucanase grade is choosing the assay that defines the unit and the form that carries it, not only the activity figure.

Why an enzyme grade is not a purity grade

An enzyme preparation is not described by a purity percentage. It contains the active enzyme, leftover fermentation solids and whatever carrier was used to set the final activity. The description that matters is therefore the declared activity, the method behind it, the source and the physical form. Two powders can both say 50,000 U/g and behave differently in the same blend.

Beta-glucanase adds a particular trap: the unit name is not unique to one substrate. A U/g figure on barley beta-glucan and a U/g figure on lichenin or carboxymethyl cellulose are different measurements, and the grade is not defined until the method is.

The lines that define a beta-glucanase grade
Grade lineWhat it setsWhere it matters
Activity (U/g)Units delivered per gramDose weight, label statement, overage
Unit definitionWhich assay produced the numberComparability with another supplier
CarrierWhat the activity sits onIngredient declaration, water content, flow
Particle sizeHow fast the powder wets and how much dust it makesBlend uniformity, dust control
FormPowder or granuleDissolution rate, handling
Production organismSpecies and strain behind the lotIdentity dossier, market file
Declared basisRelease activity or activity promised at shelf-life endLabel claim and specification headroom

The catalog forms side by side

The catalog lists one activity grade in two forms: an 80 mesh powder and a granulated form on request. A different activity is a separate specification rather than a catalog grade, and it should be quoted as its own document with its own certificate.

Beta-glucanase forms compared
OptionActivityFormWhat changes
Standard powder≥50,000 U/g80 mesh powderFast wetting, highest dust, smallest dose weight
GranulatedSet in the specificationGranulesLess dust, slower wetting, activity lost in granulation
Other activity (separate specification)Set in that specificationAgreedNew certificate, new dose weight, new carrier load

Granulation is not a dilution. It binds the same powder into larger particles, so the activity per gram can stay close to the powder, but the binding step itself costs activity, and the figure after granulation belongs in the specification. A change of activity is a different material: the units per gram, the mass per batch and the carrier entering the formula all move.

80 mesh, dust and dissolution

The catalog particle size is ≥95% through 80 mesh, which is finer than the 40 mesh common for cellulase. The finer powder wets and disperses faster, and it also makes more dust. Enzyme powders are respiratory sensitisers, so the SDS, local exhaust ventilation, closed transfer and a suitable mask belong in the handling plan, not in a footnote.

Granulation buys dust control with a slower dissolve. A drink mix that must disperse quickly usually takes powder; a plant handling kilos of enzyme a day may choose granules to keep dust out of the air. Particle size is a specification line, not a packing choice: a coarser powder is a different mesh and a different document.

The arithmetic behind the dose

Units are mass multiplied by activity. One kilogram at 50,000 U/g carries 50 million U. A blend built for 2 million U takes 40 g of that powder; the same 2 million U from a 10,000 U/g preparation would take 200 g, and the extra 160 g is carrier. The arithmetic is exact, and the unit is not convertible to CU/g.

Weighability usually settles the choice. A 40 g charge is routine in production and awkward in a pilot; a dilution makes the units weighable while adding carrier to the label and the moisture budget. State the basis as well: the activity at release, or the activity promised when the shelf life ends. Those are different promises; a label that leaves the choice unstated is ambiguous.

Writing the grade specification

Six lines make the grade testable: enzyme name, EC 3.2.1.6 and CAS 9025-70-1; activity ≥50,000 U/g with the method reference; substrate, pH and temperature; protein or specific activity; loss on drying ≤8.0% and ≥95% through 80 mesh; and the source strain, carrier and form. Add the declared basis and the storage statement.

Write the activity as "not less than" and keep the method under change control, because a change of substrate or conditions leaves two U/g results that cannot be compared. The catalog figures sit on the beta-glucanase product page; the certificate lines are read on the COA page; the stability of each form is on the stability page; the unit comparison with cellulase is on the beta-glucanase vs cellulase page; and the assay vocabulary is in the assay glossary entry.

When the granule or the finer mesh is the wrong choice

A granule is wrong when the product must disperse in seconds, because the granule wets more slowly and can leave a lump in a cold drink mix. A finer powder is wrong when dust control is the constraint, because the same surface area that speeds wetting also puts more enzyme into the air. A lower-activity dilution is wrong when the carrier load already sits at its limit or when the moisture budget is tight.

None of those arguments changes the assay. The unit stays the same, the substrate stays the same and the certificate has to carry both. The form changes; the identity does not.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation