03 Stability

Beta-glucanase activity falls with heat and moisture; the process sets the shelf life

Technical document 03 · Reviewed 2026-11-20 · Beta-Glucanase

On this page
  1. The powder: moisture, heat and the seal
  2. In solution the clock runs faster
  3. What drives the loss
  4. Designing the stability study
  5. The formula changes the answer
  6. How the shelf life is assigned

Dry beta-glucanase powder loses activity slowly in a sealed pack, and the loss accelerates with moisture, heat and time. A wet process step can remove more activity in an hour than months of storage, and the 80 mesh powder picks up moisture quickly once the pack is open. Shelf life is assigned from data for the exact pack and matrix, not from the certificate.

In one line

A sealed pack holds the activity; moisture, heat and the wet step of the process decide how much is left at the end of shelf life.

The powder: moisture, heat and the seal

At low water activity the enzyme is close to inert. With little water present, the protein is immobile and the reactions that destroy it are slow. A sealed foil pouch or a lined fiber drum at room temperature therefore keeps the declared activity for a long time, and month-to-month loss is small next to what one wet process step can remove.

The catalog sets loss on drying at ≤8.0%. That is a release limit, not an allowance for storage. An opened pouch takes water from the room air, and the 80 mesh powder has enough surface area to do it quickly. Keep the pack closed until the batch is ready, reseal it properly between weighings, and let a cold-stored pack reach room temperature before opening, so water does not condense on the powder.

Heat raises the rate of both moisture damage and protein unfolding. A sealed pack in a normal warehouse is usually acceptable; a hot loading bay, a parked car or a glasshouse is not. The certificate should name that condition.

In solution the clock runs faster

Dissolved, the enzyme becomes a protein in water, its native structure exposed, and activity can fall fast enough to become a process problem rather than a storage footnote. Temperature, pH and hold time govern the rate. A solution kept warm for a shift can lose a noticeable share of its activity before the filling line is reached.

Beta-glucanase is used in process streams such as brewing and wine filtration, where it works for a defined hold rather than for a shelf life. The useful question is how much activity remains at the end of that hold, at the process pH and temperature.

Pasteurisation and hot fill are the hard cases. A heat step of minutes at 70–90 °C can strip much of the activity, and cooling does not bring it back. If the process needs that heat, dose for the far side of it and measure the activity after the step.

What drives the loss

What shortens beta-glucanase activity, and the control for each route
FactorWhat happensControl
Heat above the working windowThe protein unfolds; the loss is irreversibleDose after the heat step, or add an overage
Moisture in the powderWater restores mobility; hydrolysis and oxidation resumeSealed pouch; reseal; desiccant where needed
pH away from the assay windowThe structure changes and the rate fallsCheck the matrix pH; buffer the wet blend
Wet granulationWater, binder and drying heat togetherLow-water binder; brief cool dry
Tablet compressionLocal heat and shear at the punchDirect compression; measure activity in the tablet
Trace metalsIron and copper speed up protein oxidationCheck the mineral sources; test the blend
Opening the packHumid air enters the headspaceReseal; use small packs for samples

The factors are not independent: a warm, humid store or a wet blend at the wrong pH combines them. The question is not whether beta-glucanase is stable, but in which pack, at which condition and for how long.

Designing the stability study

Three production lots, one assay method, and time points at 0, 3, 6, 9, 12 and 24 months at 25 °C/60% relative humidity. Add a second condition at 30 °C/65% relative humidity, or 30 °C/75% for a tropical market, plus an accelerated arm at 40 °C/75% for six months.

Test activity, loss on drying, appearance and microbiology at every point. Run the study on the material the customer receives, in the pack the customer receives: a concentrate in a laboratory jar says little about a granulated grade in a foil pouch. Where a process step is planned, test the blend before and after it so the loss from processing is measured, not guessed.

Report the result as a percentage of the initial activity as well as the absolute figure. A lot that starts at 60,000 U/g and ends at 51,000 U/g has lost 15%, and the absolute figure alone hides whether the fall came from the powder or from where it started. The methods library describes the assay formats behind those figures.

The formula changes the answer

A capsule or tablet begins with low water activity, but the shell and excipients can still pass moisture into the fill, so activity and loss on drying are checked at release and again after storage. A stick pack fails at a seam: one pinhole in the laminate lets water in, so the strip is checked as well as the powder. Neither format can borrow the bulk pouch's shelf life.

A beverage combines pH, heat and oxygen. An acidic fruit powder drops the local pH as soon as water appears, and ascorbic acid with a trace of iron or copper produces oxidants that damage the protein. Direct compression and dry blending are gentler because no water is added and no drying heat is applied. If granules are needed, keep the binder low in water and the dry short and cool, then measure the activity of the granule rather than calculating it from the powder.

Packaging completes the picture: a foil laminate with a sound seal, a desiccant where humidity demands one, and little headspace all slow the loss. A stick pack is not a drum; its surface area per gram is much larger.

How the shelf life is assigned

Beta-glucanase has no single shelf-life figure, because the pack and the storage condition decide it. The retest period is written into the specification and backed by stability data for that pack. A shelf-life figure without a pack, a storage condition and a test panel is only an assertion.

One lot is not a shelf life. Three lots show the batch-to-batch spread; one lot may simply be a good one. If the label claims “not less than 50,000 U/g at end of shelf life”, the release specification needs headroom above that figure to cover the loss and the spread, and the stability data determines how much. Past the retest date, assay the retained sample again before extending use.