02 Grade comparison

100,000 U/g, a granulation or a dilution: choosing an acid protease grade

Technical document 02 · Reviewed 2026-11-19 · Acid Protease

On this page
  1. Concentration first, then mass
  2. Three options, one unit definition
  3. What the powder does in the room
  4. Fitting the unit target into the pack
  5. What the specification should say
  6. When the answer is to keep the grade

The standard acid protease grade is a 40 mesh powder at ≥100,000 U/g, packed at 1 kg and 25 kg. Granulation can be ordered for flow or dust control, and a lower-activity dilution can be agreed as its own specification. The decision is about how much powder one dose needs, how the powder behaves in the room and what the label declares.

In one line

A grade changes the activity per gram, the particle and the carrier, while the enzyme and its acid behaviour stay the same.

Concentration first, then mass

Begin with the unit target. The catalog powder carries 100 U of activity in every milligram, because 100,000 U/g is 100 U/mg. A capsule that needs 10,000 U takes 0.1 g of this powder; at 50,000 U/g the same capsule would take 0.2 g, and at 25,000 U/g it would take 0.4 g. Fill weight, capsule size and blend space all follow from that division.

The concentrate is the natural choice for a small inclusion. A dilution can make a low unit target easier to weigh, at the price of more carrier and a longer ingredient list. Granulation changes the particle, not the activity per gram, although the process used to make the granule can cost activity.

Three options, one unit definition

Acid protease grades · what changes in the drum
GradeActivityWhat it isFitsWatch
Catalog 40 mesh powder≥100,000 U/gThe standard preparation; carrier declared on the COACapsules, tablets and small inclusionsDust, static and tiny weighings
Granulated powderSame unit definitionAgglomerated particles, made to orderTableting, sachets and low-dust roomsHeat and moisture during granulation
Lower-activity dilutionSet in the specificationStandard powder plus a declared carrierStick packs and blends that need bulkCarrier declaration; separation in the blender

A dilution is a legitimate grade only when its carrier and its lower activity are in the specification. It is not a way to keep a 100,000 U/g label on a weaker powder.

What the powder does in the room

A 40 mesh powder passes about 425 µm openings. It pours, it dusts and it can hold static, which makes a small weighment wander on the balance. Enzyme dust is a respiratory sensitiser, so the room needs extraction or a weighing booth and the operator needs the controls in the safety data sheet.

Granulation can cut dust and improve flow, but it adds variables: the binder, any liquid, the dryer setting and the final milling. Each becomes a specification line, and the activity must be re-measured on the granule rather than inferred from the base powder. For a dilution, test the particle-size distribution of the blend, not just the enzyme, because a dense carrier and a light powder can stratify in a hopper.

Fitting the unit target into the pack

Put the grade into the dosage form. A capsule with 5,000 U needs 0.05 g of the standard powder, a small charge that is hard to weigh by hand and easy to lose in a blend. A 20,000 U/g dilution would need 0.25 g, which is easier to handle but adds carrier to the formula.

A tablet press rewards consistent flow; granulation may help a powder that would otherwise bridge in the hopper, though any wet step brings heat and water into the process. A stick pack rewards dispersion, and a dilution can reduce clumping. In a multi-enzyme blend, changing one component's concentration changes the ratio and the uniformity of the smallest ingredient, and the acid enzyme still needs its local pH to stay in range.

What the specification should say

  • “Acid protease preparation, CAS 9025-49-4, ≥100,000 U/g, with the production organism named.”
  • “The U defined by the Folin-Ciocalteu assay at the stated acid pH, with substrate, temperature, time and standard on the COA.”
  • “Activity reported as-is; loss on drying ≤8.0%.”
  • “Particle size ≥95% through 40 mesh; a granulated grade to the agreed size.”
  • “Carrier named and quantified; a dilution specified separately from the concentrate.”
  • “Heavy metals and microbiology as listed; activity measured after granulation.”

Changing grade changes the paperwork as well. Specification, certificate, label, blend sheet and stability summary all have to be reissued; only the unit definition is unchanged. Without those revisions, one product name covers two different materials.

When the answer is to keep the grade

Keep the catalog grade when the label already declares 100,000 U/g; a dilution would force a label change. Keep the powder when it already flows well; granulation brings heat and moisture but no extra units. Do not introduce a carrier that the customer's specification or the label excludes, and do not choose a dilution so coarse that the capsule can no longer hold the dose.

The catalog numbers sit on the acid protease product page; the release lines are on the COA page; the pH comparison is on the neutral protease page; the alkaline alternative is on the alkaline protease page; and the assay families are described in the methods index.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.