03 Stability

Acid protease loses activity with heat and moisture; pH decides where it survives

Technical document 03 · Reviewed 2026-11-19 · Acid Protease

On this page
  1. The dry pack is the benchmark
  2. A liquid hold is a different material
  3. What drives the loss
  4. Test the powder, then the process
  5. Give the enzyme a dry, late place in the process
  6. How the shelf life is set

Acid protease keeps its activity in a sealed, cool, dry pack and loses it when water, heat or a higher pH reaches the protein. The catalog limits — ≥100,000 U/g and loss on drying ≤8.0% — describe the powder when it is released; they say nothing about an opened pouch or a tablet. The retest period is set from data for the pack and storage condition that will actually be used.

In one line

The dry powder keeps its activity only while the pack keeps water and heat out; in solution, the pH and the hold time decide what is left.

The dry pack is the benchmark

Dry and cool, the powder ages slowly. Water is the switch that changes the rate: the ≤8.0% loss-on-drying limit is a release gate, not a storage allowance. Two powders can pass the same gate and still behave differently if one holds more free water. Water activity in the blend is the better predictor.

Packaging is part of the control. The 1 kg pouch is a moisture barrier; the 25 kg drum relies on its liner. A desiccant can help, but it cannot replace a closed seal. Close the pouch between weighings, keep the drum off a damp floor and record the opening date. If the powder has already taken up water, drying it back is not a repair: the activity lost does not return.

A liquid hold is a different material

Dissolved, the enzyme is exposed to water, substrate and itself. The powder gives an acidic solution; the common working range is about pH 2.5–3.5, with useful activity toward pH 6. That range describes catalysis, not stability.

Keep any liquid stage short and cool, and assay after the hold. A freeze–thaw cycle adds another loss route. Microbial growth is a separate risk in a liquid, so hold time, preservative and micro control belong to the same study. The dry powder is the storage form; a solution is a process intermediate.

What drives the loss

Stability factors · mechanism and control
FactorWhat it doesControl
TemperatureThe rate of unfolding rises with heat; steam is worse than dry heatCap dryer and granulator temperatures; assay after the step
WaterFree water lets the protein unfold and the powder cakeSealed pack; desiccant; control water activity
pH above 6Takes the enzyme outside its acid working rangeCheck blend pH; avoid alkaline salts
Protein substrateIn a wet mix the enzyme acts on nearby protein and on itselfKeep blends dry; limit wet holds
Metal ionsCopper and iron can inhibit the enzyme in solutionUse compatible contact surfaces; validate the wet process

The rows combine. A warm, wet granulation adds heat and water at once, and an alkaline salt beside the enzyme adds a pH shift together with the moisture it brings. The useful stability question is not whether acid protease is stable in general, but whether this powder in this pack holds its activity for the declared period.

Test the powder, then the process

Design the study around the pack and the matrix. Long-term storage at 25 °C/60% relative humidity and intermediate storage at 30 °C/65% relative humidity cover the warehouse; 40 °C/75% relative humidity is an early warning, not a shelf-life assignment. Test activity, loss on drying, appearance and microbiology at 0, 1, 3, 6, 9, 12, 18 and 24 months.

Then challenge the process: granulation, drying, tableting, blending. Sample before and after, assay both, and store the finished form at the intended condition. Bracketing is acceptable when the wettest and hottest arm is included. Keep a retained sample per lot and per time point, and record the assay method beside each result so a method change cannot read as a stability change.

Give the enzyme a dry, late place in the process

Place the enzyme late in the process and keep water out of the steps before it. Dry blending and direct compression avoid water; aqueous granulation, film coating and hot drying do not. If a wet step is unavoidable, assay after drying rather than assuming a fixed loss.

Watch the local pH. Calcium carbonate, magnesium oxide and sodium bicarbonate can lift the pH above the acid window; citric acid and ascorbic acid sit within it. Measure the blend pH at the start and after storage. Also measure water activity, because a hygroscopic excipient can pull moisture from the air and raise the water activity of the whole blend. An overage needs measured process loss behind it; it is not a substitute for a formula that holds the enzyme.

How the shelf life is set

There is no universal number. The retest period is a property of the pack, the storage condition and the test panel, and it belongs on the specification with the data behind it.

State whether the declared activity is at release or at the end of the period. A sealed pouch in a cool store and an opened pouch in a warm room are different products after a month. Re-assay the retained sample before extending use, and do not transfer a bulk result to a repacked container. The release lines are on the COA page; the packs and order details are on the MOQ page; the pH comparison is on the neutral protease page; the assay families are described in the methods index; and the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.