01 COA & batch testing

What the COA for L-threonine reports, and on what basis

Technical document 01 · Reviewed 2026-11-19 · L-Threonine

On this page
  1. The certificate as a test report
  2. The dried basis, the HPLC method and the rotation
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

An L-threonine certificate reports appearance, identification by infrared and HPLC, assay by HPLC on the dried basis, specific rotation, loss on drying, pH, heavy metals, microbiology and particle size. The assay measures how much threonine is present; the rotation assigns the L configuration, and the allo-threonine check covers the second stereocentre. The limits below are the catalog specification; the batch COA confirms a particular pack.

In one line

The assay measures the threonine peak; the rotation and the allo-threonine check fix the stereochemistry; the dried basis says what the percentage refers to.

The certificate as a test report

A certificate can be audited only when each line names the test, the method and the release limit. A row that says “conforms” without a method asks the reader to accept a conclusion. The identity line decides whether the material is threonine, and the rotation decides which stereoisomer.

Identity, assay and physical limits · L-threonine
ParameterMethodRelease limit
AppearanceVisualWhite crystalline powder
IdentificationInfrared and HPLCConforms to the reference
Assay (dried basis)HPLC98.5–101.5%
Specific rotationPolarimetry, dried basis-26.5° to -29.0°
Loss on dryingGravimetric≤0.5%
pH (1% solution)Potentiometry5.0–7.0
Heavy metalsICP-MS or ICP-OESPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 40 mesh

The dried basis, the HPLC method and the rotation

The assay is reported on the dried basis. The laboratory measures the powder as received and divides by the dry matter; the loss on drying is the correction. The certificate should print the basis in the assay row and the loss on drying beside it, not hide either in a footnote.

Threonine has no strong ultraviolet chromophore, so an HPLC assay needs a detection mode. Most methods derivatise the amino acid before the column, with ortho-phthalaldehyde, FMOC or AQC, and read ultraviolet or fluorescence; LC-MS/MS is the other route. “HPLC” without the derivatisation and detector does not say how the peak was measured. Ask for the chromatogram.

Specific rotation belongs on the same dried basis, with the solvent, concentration, temperature and path length. The catalog window is -26.5° to -29.0°. The figure is consistent with L-threonine, but it is a weighted property: another stereoisomer can pull the reading while the assay still passes. Rotation is a gate, not a stereochemical proof.

pH at 1% is 5.0–7.0, close to the isoelectric point of 5.60. A shift points to residual acid or alkali, a different salt or a blend. The catalog does not set an allo-threonine limit; agree one with the supplier.

Release limit versus batch result

The release limit is the boundary; the batch result is the measurement. They belong in separate columns with the method and basis. A result column filled with the range is a copy of the gate, not a record of the lot.

What the result column should contain · L-threonine
ParameterRelease limitResult column
Assay98.5–101.5% dried basisA measured percentage, with the HPLC method and the basis
Specific rotation-26.5° to -29.0° dried basisA measured angle, with solvent, concentration and temperature
Loss on drying≤0.5%A measured percentage
Heavy metalsPer elementA measured figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot
Particle size≥95% through 40 meshThe measured percentage through the sieve

“Passes specification” is a conclusion the reader should be able to reach from the numbers. A heavy-metal total is not enough; the element that matters has to be visible, and a micro line needs a count and an absence statement.

What moves between batches

Fermentation and crystallisation move the assay, the colour and the trace impurities; drying moves the loss on drying; milling and sieving move the particle-size result. The 40 mesh line is a finishing specification, so it can change when the mill or the sieve changes without any change in the chemistry.

Rotation is the line to watch between lots. A drift toward the edge of the window with a flat assay can mean a small D or allo fraction, a change in the polarimeter conditions or a different source. One edge result is not a rejection; a sequence is a supplier question.

Colour is descriptive and easy to over-read. A white crystalline powder can pick up a grey or yellow tint from hot drying, iron contact or a dirty mill while the assay passes. Ask for the batch record before rejecting on appearance alone. The lot code on the certificate should match the pouch, the drum and the retained sample.

When to order an outside test

Order an independent test for a new source, a first shipment into a regulated market, a rotation that does not fit, or a suspected serine or allo-threonine substitution. A targeted panel is enough: HPLC with the derivatisation and detector stated, specific rotation with the conditions, chiral HPLC for D-threonine, achiral HPLC for allo-threonine, LC-MS for the molecular weight, ICP-MS for the metals and a plate count.

Ask the laboratory to report its detection and quantification limits. “Allo-threonine not detected” without a limit describes the method's sensitivity, not the sample. Keep the chain of custody: the sample tested should be the sample retained, and the report should identify the lot. When a result is contested, give the referee the retained sample and ask for tests that separate the stereoisomers.

What to compare between suppliers

Put six lines side by side: identity and CAS number; assay method and basis; rotation with conditions; allo-threonine and D-threonine results; water, pH and mesh; heavy metals and microbiology. Two quotations that agree on assay but differ on rotation or on the allo check are not describing the same specification.

Six lines for a supplier comparison · L-threonine
LineWhat to compareWhy it matters
IdentityL-threonine, CAS 72-19-5, C4H9NO3A DL or allo lot can be sold under a similar name
AssayHPLC, 98.5–101.5% dried basis, with the detection modeMethod and basis set what the percentage means
Rotation-26.5° to -29.0° dried basis, with solvent and temperatureConfiguration is not visible in the assay
StereochemistryAllo-threonine result and limit; D-threonine by chiral HPLCThe second stereocentre is the threonine-specific risk
PhysicalLoss on drying ≤0.5%; pH 5.0–7.0; ≥95% through 40 meshWater and mesh change the weigh-up and the fill
ContaminantsPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg; micro panelRelease limits are part of the specification

The certificate should name the manufacturer and the lot, and the lot code should match the pack and the retained sample. The catalog specification is on the L-threonine product page; the stereochemistry is taken further on the identity page; the forms are compared on the grade page; the HPLC method is described in the HPLC method note; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation